DENO LED Lighting

Fita de LED 2835 Clássica de Alta Eficiência e Desempenho Estável (#16799)

10mm · 48V · 128LEDs · 125mm/corte

Model: 16799

16799 Fita de LED 2835 Clássica de Alta Eficiência e Desempenho Estável — 48V, corte a cada 125 mm, FPCB de 10 mm, LEDs 2835, 128 LEDs/m, IP20/IP54/IP65/IP67/IP68Desenho dimensional 16799 Fita de LED 2835 Clássica de Alta Eficiência e Desempenho Estável — FPCB de 10 mm, corte a cada 125 mm, 48V16799 Fita de LED 2835 Clássica de Alta Eficiência e Desempenho Estável — 48V, corte a cada 125 mm, FPCB de 10 mm, LEDs 2835, 128 LEDs/m, IP20/IP54/IP65/IP67/IP68 (vista 3)16799 Fita de LED 2835 Clássica de Alta Eficiência e Desempenho Estável — 48V, corte a cada 125 mm, FPCB de 10 mm, LEDs 2835, 128 LEDs/m, IP20/IP54/IP65/IP67/IP68 (vista 4)16799 Fita de LED 2835 Clássica de Alta Eficiência e Desempenho Estável — 48V, corte a cada 125 mm, FPCB de 10 mm, LEDs 2835, 128 LEDs/m, IP20/IP54/IP65/IP67/IP68 (vista 5)16799 Fita de LED 2835 Clássica de Alta Eficiência e Desempenho Estável — 48V, corte a cada 125 mm, FPCB de 10 mm, LEDs 2835, 128 LEDs/m, IP20/IP54/IP65/IP67/IP68 (vista 6)

Visão Geral

10mm | 48V | 128LEDs | 125mm/corte | #16799 | A Fita de LED 2835 Clássica Estável de Alta Eficiência faz parte da série de Fitas SMD Clássicas da DENO, desenvolvida com base em Fitas de LED SMD de 24V. Principais especificações: 2835, 128, DC 48V, PCB de 10mm, FPCB com cobre de 3oz, corte a cada 16LEDs/125mm. Cada rolo é produzido na linha rolo a rolo da DENO com FPCB de cobre com pureza de 99.9% e é fornecido em conformidade com CE, UL e RoHS para projetos de arquitetura, varejo e hotelaria. Configurações OEM e ODM de comprimento, Temperatura de Cor (CCT) e impermeabilização estão disponíveis mediante solicitação.

Descrição

Operando em um sistema de tensão constante DC 48V com folha de cobre de 3oz, esta Fita de LED 2835 suporta trechos contínuos de até 15m alimentados por uma única extremidade, sem queda de tensão. Com 128 LEDs por metro em uma PCB de 10mm e incrementos de corte de 125mm, combina-se com Perfis de Alumínio para oferecer iluminação arquitetônica uniforme sem descontinuidades visíveis. Disponível em temperaturas de cor de 2700K a 6500K ou em Espectro Completo personalizável, o design dimerizável proporciona um amplo ângulo de visão de 120 graus para iluminação consistente. Projetado com uma faixa de potência adaptável de 3.8W a 23W, este modelo foi desenvolvido para comprimentos personalizados OEM e fornecimento de projetos no atacado diretamente da fábrica.

48v Led Strip Lights built for 48v smd strips projects.

Especificações

IRC (CRI)Ra≥80 / Ra≥90 / Ra≥95
LED QTY128
PART NODL-F28A64V48-16799
SMD TYPE2835
UNIDADE DE CORTE16LEDs/125mm
DIMERIZÁVELYes
GRAU DE PROTEÇÃO IPIP20/IP54/IP65/IP67/IP68
LED PITCH7.8mm
LARGURA DA PCB10mm
COMPRIMENTO DO TRECHO15m
COPPER FOIL3oz
POWER RANGE3.8~23W
TIPO DE CIRCUITOC.V.
INPUT VOLTAGEDC 48V
FLUXO LUMINOSO1951 lm/m@4000K

Aplicações

  • Sancas, banho de luz em paredes e perímetros — Sancas, rebaixos, detalhes de banho de luz e perímetros de teto que exigem uma linha de luz contínua e uniforme.
  • Iluminação de exposição em showrooms e hotelaria — Prateleiras, vitrines, balcões de recepção e retroiluminação de letreiros em lojas, showrooms e espaços de hotelaria.
  • Iluminação sob armários de cozinha e closets — Iluminação de tarefa em cozinhas, closets e móveis, onde a fita fica oculta e apenas a luz é vista.
  • Trechos longos em corredores e armazéns — Trechos longos com alimentação única em 48 V cobrem corredores, ruas de armazéns e linhas de fachada com menos pontos de alimentação e menos fontes.

Acessórios recomendados e peças compatíveis

  • DL-1003 — 19.1x8mm Surface Mount LED Channel — Dotless Aluminum Profile for 240 LEDs/m Strip: Accepts LED strips up to 10mm wide.
  • DL-1103-1 — 16x13mm Surface Mount LED Channel — Aluminum Profile for 10mm LED Strip: Accepts LED strips up to 10mm wide.
  • DL-1510 HX-F — 15x9.9mm Recessed LED Channel with Flange — Flush Mount Aluminum Profile: Accepts LED strips up to 10mm wide.

Solicite um orçamento para #16799

A DENO LED é uma fabricante de fitas de LED com sede em Shenzhen e base de produção própria em Foshan. Envie-nos o comprimento do trecho, tensão, CCT/IRC e grau de proteção IP que você precisa e nossa equipe de engenharia responderá com uma ficha técnica, diagrama de fiação e preço — OEM/ODM e projetos totalmente personalizados incluídos.

Garantia
Conforme a ficha técnica do modelo
Prazo de entrega
Amostras personalizadas: 3–5 dias úteis · novo desenvolvimento: 1–3 semanas · produção em série: 1–2 semanas após aprovação da amostra
Conformidade
CE · RoHS · UL/ETL conforme o modelo e o mercado
Fio de ligação
Ouro puro 99,99%
Folha de cobre
FPCB de cobre puro 99,9%
Serviços
CCT, IRC, largura de PCB, unidade de corte e embalagem personalizadas — amostras e produção em massa de uma única fábrica.

Desempenho Fotométrico — Matriz de Eficácia CCT × IRC (CRI)

Peak measured luminous efficacy: 176.2 lm/W at 4000K, Ra 80, ErP energy class C (Grade DN (1st Tier) · 9.6W/m).

All values are measured at the stated power density and ambient 25 °C, reported as luminous efficacy in lumens per watt (lm/W), luminous flux per metre (lm/m) and the corresponding EU ErP (2019/2015) energy class.

Grade DL (2nd Tier) · 9.6W/m

Grade DL (2nd Tier) · 9.6W/m — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K127.4 lm/W1223.3 lm/mE102.2 lm/W981 lm/mF———
2300 K141.9 lm/W1361.9 lm/mD113.8 lm/W1092.7 lm/mE———
2700 K149.8 lm/W1437.6 lm/mD123.2 lm/W1182.4 lm/mE99.8 lm/W958.1 lm/mF
3000 K159.7 lm/W1533.3 lm/mD129.6 lm/W1244.2 lm/mE105.4 lm/W1011.9 lm/mF
3500 K162.1 lm/W1556.3 lm/mC131.9 lm/W1266.2 lm/mE108.5 lm/W1041.8 lm/mF
4000 K167.3 lm/W1606.1 lm/mC135.1 lm/W1297.1 lm/mD111.5 lm/W1070.8 lm/mE
5000 K167.1 lm/W1604.1 lm/mC135 lm/W1296.1 lm/mD———
6500 K153.1 lm/W1469.5 lm/mD129.5 lm/W1243.2 lm/mE———

Grade DL (2nd Tier) · 15W/m

Grade DL (2nd Tier) · 15W/m — measured at 15 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K122.7 lm/W1840.2 lm/mE98.4 lm/W1475.8 lm/mF———
2300 K136.6 lm/W2048.7 lm/mD109.6 lm/W1643.8 lm/mF———
2700 K144.2 lm/W2162.7 lm/mD118.6 lm/W1778.8 lm/mE96.1 lm/W1441.3 lm/mF
3000 K153.8 lm/W2306.7 lm/mD124.8 lm/W1871.7 lm/mE101.5 lm/W1522.3 lm/mF
3500 K156.1 lm/W2341.2 lm/mD127 lm/W1904.7 lm/mE104.5 lm/W1567.3 lm/mF
4000 K161.1 lm/W2416.2 lm/mC130.1 lm/W1951.2 lm/mE107.4 lm/W1610.8 lm/mF
5000 K160.9 lm/W2413.2 lm/mC130 lm/W1949.7 lm/mE———
6500 K147.4 lm/W2210.7 lm/mD124.7 lm/W1870.2 lm/mE———

Grade DL (2nd Tier) · 19.2W/m

Grade DL (2nd Tier) · 19.2W/m — measured at 19.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K119.1 lm/W2287 lm/mE95.5 lm/W1834.1 lm/mF———
2300 K132.6 lm/W2546.1 lm/mE106.4 lm/W2042.9 lm/mF———
2700 K140 lm/W2687.8 lm/mD115.1 lm/W2210.6 lm/mE93.3 lm/W1791.2 lm/mF
3000 K149.3 lm/W2866.7 lm/mD121.2 lm/W2326.2 lm/mE98.5 lm/W1891.9 lm/mF
3500 K151.5 lm/W2909.6 lm/mD123.3 lm/W2367.2 lm/mE101.4 lm/W1947.8 lm/mF
4000 K156.4 lm/W3002.8 lm/mD126.3 lm/W2425 lm/mE104.3 lm/W2001.8 lm/mF
5000 K156.2 lm/W2999 lm/mD126.2 lm/W2423.1 lm/mE———
6500 K143.1 lm/W2747.4 lm/mD121.1 lm/W2324.3 lm/mE———

Grade DN (1st Tier) · 9.6W/m

Grade DN (1st Tier) · 9.6W/m — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K138.1 lm/W1326 lm/mE116.3 lm/W1116.6 lm/mF———
2300 K150.6 lm/W1445.6 lm/mD129.8 lm/W1246.2 lm/mE———
2700 K162.3 lm/W1558.3 lm/mD140.5 lm/W1348.9 lm/mE113.8 lm/W1092.7 lm/mF
3000 K170.4 lm/W1636 lm/mD148.3 lm/W1423.7 lm/mD120.6 lm/W1157.5 lm/mE
3500 K173 lm/W1661 lm/mC151.5 lm/W1454.6 lm/mD124.7 lm/W1197.4 lm/mE
4000 K176.2 lm/W1691.9 lm/mC152.4 lm/W1462.6 lm/mD125.8 lm/W1207.3 lm/mE
5000 K176 lm/W1689.9 lm/mC153.4 lm/W1472.5 lm/mD———
6500 K168.8 lm/W1620.1 lm/mD146.5 lm/W1406.7 lm/mD———

Grade DN (1st Tier) · 15W/m

Grade DN (1st Tier) · 15W/m — measured at 15 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K133 lm/W1994.7 lm/mE112 lm/W1679.8 lm/mF———
2300 K145 lm/W2174.7 lm/mE125 lm/W1874.7 lm/mE———
2700 K156.3 lm/W2344.2 lm/mD135.3 lm/W2029.2 lm/mE109.6 lm/W1643.8 lm/mF
3000 K164.1 lm/W2461.2 lm/mD142.8 lm/W2141.7 lm/mE116.1 lm/W1741.3 lm/mF
3500 K166.6 lm/W2498.6 lm/mD145.9 lm/W2188.2 lm/mD120.1 lm/W1801.2 lm/mE
4000 K169.7 lm/W2545.1 lm/mD146.7 lm/W2200.2 lm/mD121.1 lm/W1816.2 lm/mE
5000 K169.5 lm/W2542.1 lm/mD147.7 lm/W2215.2 lm/mD———
6500 K162.5 lm/W2437.2 lm/mD141.1 lm/W2116.2 lm/mE———

Grade DN (1st Tier) · 19.2W/m

Grade DN (1st Tier) · 19.2W/m — measured at 19.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K129.1 lm/W2479 lm/mE108.7 lm/W2087.6 lm/mF———
2300 K140.8 lm/W2702.7 lm/mE121.3 lm/W2329.9 lm/mE———
2700 K151.7 lm/W2913.3 lm/mD131.3 lm/W2521.9 lm/mE106.4 lm/W2042.9 lm/mF
3000 K159.3 lm/W3058.7 lm/mD138.6 lm/W2661.7 lm/mE112.7 lm/W2164 lm/mF
3500 K161.7 lm/W3105.3 lm/mD141.6 lm/W2719.5 lm/mE116.6 lm/W2238.6 lm/mF
4000 K164.7 lm/W3163.1 lm/mD142.4 lm/W2734.4 lm/mE117.6 lm/W2257.2 lm/mF
5000 K164.5 lm/W3159.3 lm/mD143.4 lm/W2753 lm/mE———
6500 K157.8 lm/W3028.9 lm/mD137 lm/W2630 lm/mE———

Grade KE (3rd Tier) · 9.6W/m

Grade KE (3rd Tier) · 9.6W/m — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K106.4 lm/W1021.9 lm/mF85.2 lm/W817.5 lm/mF———
2300 K118.7 lm/W1139.5 lm/mE94.9 lm/W911.2 lm/mF———
2700 K127.9 lm/W1228.3 lm/mE103 lm/W989 lm/mF83.5 lm/W801.6 lm/mG
3000 K134.4 lm/W1290.1 lm/mE108.8 lm/W1044.8 lm/mF88.5 lm/W849.4 lm/mF
3500 K136.4 lm/W1309 lm/mD111 lm/W1065.8 lm/mE91.4 lm/W877.3 lm/mF
4000 K140.4 lm/W1347.9 lm/mD113.4 lm/W1088.7 lm/mE93.6 lm/W898.3 lm/mF
5000 K140.2 lm/W1345.9 lm/mD113.3 lm/W1087.7 lm/mE———
6500 K134.4 lm/W1290.1 lm/mE108.8 lm/W1044.8 lm/mF———

Grade KE (3rd Tier) · 15W/m

Grade KE (3rd Tier) · 15W/m — measured at 15 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K102.5 lm/W1537.3 lm/mF82 lm/W1229.8 lm/mG———
2300 K114.3 lm/W1714.3 lm/mE91.4 lm/W1370.8 lm/mF———
2700 K123.2 lm/W1847.7 lm/mE99.2 lm/W1487.8 lm/mF80.4 lm/W1205.8 lm/mG
3000 K129.4 lm/W1940.7 lm/mE104.8 lm/W1571.8 lm/mF85.2 lm/W1277.8 lm/mF
3500 K131.3 lm/W1969.2 lm/mE106.9 lm/W1603.3 lm/mF88 lm/W1319.8 lm/mF
4000 K135.2 lm/W2027.7 lm/mD109.2 lm/W1637.8 lm/mF90.1 lm/W1351.3 lm/mF
5000 K135 lm/W2024.7 lm/mE109.1 lm/W1636.3 lm/mF———
6500 K129.4 lm/W1940.7 lm/mE104.8 lm/W1571.8 lm/mF———

Grade KE (3rd Tier) · 19.2W/m

Grade KE (3rd Tier) · 19.2W/m — measured at 19.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K99.5 lm/W1910.5 lm/mF79.6 lm/W1528.4 lm/mG———
2300 K111 lm/W2130.5 lm/mE88.7 lm/W1703.6 lm/mF———
2700 K119.6 lm/W2296.3 lm/mE96.3 lm/W1849 lm/mF78.1 lm/W1498.6 lm/mG
3000 K125.6 lm/W2411.9 lm/mE101.7 lm/W1953.4 lm/mF82.7 lm/W1588.1 lm/mG
3500 K127.5 lm/W2447.3 lm/mE103.8 lm/W1992.5 lm/mF85.4 lm/W1640.2 lm/mF
4000 K131.3 lm/W2520 lm/mE106 lm/W2035.4 lm/mF87.5 lm/W1679.4 lm/mF
5000 K131.1 lm/W2516.3 lm/mE105.9 lm/W2033.5 lm/mF———
6500 K125.6 lm/W2411.9 lm/mE101.7 lm/W1953.4 lm/mF———

High-Power LED Strip: Heat Dissipation & Aluminum Channel Guide

At up to 19.2W/m, 16799 is a high-power SMD LED strip. Above roughly 14.4W/m the tape can no longer shed its own heat through the FPC alone — an aluminum channel is part of the luminaire, not an accessory.

Why high-wattage strips need a heat sink

  • Aluminum conducts heat roughly 30× faster than the plastics, MDF or gypsum a strip is usually stuck to, so a bare high-power run traps heat under the tape.
  • LED lifetime (LM-80 / TM-21) is driven by solder-point temperature Tc. Keeping Tc inside the datasheet limit — DENO strips are rated Tc ≤ 75°C — is what preserves the rated L70 lifetime and colour stability.
  • Never run 14.4W/m or more coiled on the reel, inside a sealed plastic diffuser, or directly on wood, wallpaper or foam.

Sizing rule: FPC width vs channel inner width

  • Channel inner width ≥ FPC width + 2mm. This strip is 10mm wide, so it needs at least 12mm of inner width.
  • The 2mm clearance absorbs extrusion tolerance and lets the tape be seated or replaced without scraping the side walls or the wiring.
  • A frosted or opal PC cover then diffuses the higher lumen output into an even, dot-free line instead of visible hot spots.

Aluminum channels that fit this strip

Recommended LED Channels

Mount this LED strip in a DENO LED aluminum profile for heat dissipation, physical protection and diffused, dot-free output.

This strip is 10mm wide, so it needs a channel with at least 12mm inner width (10mm + 2mm clearance). Every profile below meets that.

Modelos relacionados nesta série

See every model in SMD LED Strip Series or narrow to High Efficiency. Compare wattage, lumen output and run length in the ProCalc parameter library, or request OEM/ODM pricing on the custom manufacturing page.

Perguntas Frequentes

Quais dados estão registrados para o modelo 16799?

tensão: DC 48V; largura da PCB: 10mm; LEDs: 128; encapsulamento: 2835; unidade de corte: 16LEDs/125mm; cobre: 3oz. Consulte a ficha técnica para a configuração do pedido.

Como confirmar a potência e a alimentação do modelo 16799?

Confirme a configuração na tabela de parâmetros do produto antes de dimensionar a fonte. Não extrapole comprimentos, corrente ou condições térmicas sem validação da instalação.

Como solicitar a configuração do modelo 16799?

Informe o modelo e as necessidades do projeto no pedido de orçamento. Temperatura de cor, proteção, amostra e prazo devem ser confirmados para a configuração solicitada.

Engineering & selection guide

Bending limits, IP selection, voltage drop, cutting and the full buyer Q&A for this family are kept on the series page.