DENO LED Lighting

Fita de LED 2835 de Corrente Constante, Alto Fluxo Luminoso e Alta Eficácia Luminosa (#3410)

12mm · 24V · 160LEDs · 50corte

Model: 3410

3410 Fita de LED 2835 de Corrente Constante, Alto Fluxo Luminoso e Alta Eficácia Luminosa — 24V, corte a cada 50 mm, FPCB de 12 mm, LEDs 2835, 160 LEDs/m, IP20Desenho dimensional 3410 Fita de LED 2835 de Corrente Constante, Alto Fluxo Luminoso e Alta Eficácia Luminosa — FPCB de 12 mm, corte a cada 50 mm, 24V3410 Fita de LED 2835 de Corrente Constante, Alto Fluxo Luminoso e Alta Eficácia Luminosa — 24V, corte a cada 50 mm, FPCB de 12 mm, LEDs 2835, 160 LEDs/m, IP20 (vista 3)3410 Fita de LED 2835 de Corrente Constante, Alto Fluxo Luminoso e Alta Eficácia Luminosa — 24V, corte a cada 50 mm, FPCB de 12 mm, LEDs 2835, 160 LEDs/m, IP20 (vista 4)3410 Fita de LED 2835 de Corrente Constante, Alto Fluxo Luminoso e Alta Eficácia Luminosa — 24V, corte a cada 50 mm, FPCB de 12 mm, LEDs 2835, 160 LEDs/m, IP20 (vista 5)3410 Fita de LED 2835 de Corrente Constante, Alto Fluxo Luminoso e Alta Eficácia Luminosa — 24V, corte a cada 50 mm, FPCB de 12 mm, LEDs 2835, 160 LEDs/m, IP20 (vista 6)

Visão Geral

12mm | 24V | 160LEDs | 50cut | #3410 | Fita de LED 2835 de Corrente Constante, Alto Fluxo Luminoso e Alta Eficácia Luminosa faz parte da série de Fitas SMD C.C. (Reguladas por IC) da DENO, desenvolvida para Fita de LED com IC de corrente constante. Especificações principais: 2835, 160 LEDs/m, 24V, 12 PCB, FPCB de cobre de 3oz, corte a cada 8LEDs/50mm. Cada rolo é produzido na linha roll-to-roll da DENO com FPCB de cobre com pureza de 99.9% e é fornecido em conformidade com CE, UL e RoHS para projetos de arquitetura, varejo e hotelaria. Configurações OEM e ODM de comprimento, temperatura de cor e impermeabilização estão disponíveis sob consulta.

Descrição

O projeto de corrente constante em todo o circuito de 24V garante iluminação uniforme e brilho estável ao longo de todo o trecho máximo de 5m. Com 160 LEDs por metro em uma PCB de cobre de 12mm e 3oz, esta Fita de LED 2835 oferece alto fluxo luminoso e eficácia superior. Esta fita dimerizável permite cortes a cada 50mm e suporta vários protocolos de dimerização, incluindo PWM, DALI e 0-10V, para um controle versátil da iluminação. Desenvolvida para fornecimento de projetos no atacado, esta solução flexível oferece iluminação confiável e de alto desempenho para vitrines comerciais e instalações de iluminação arquitetônica.

We use 99.99% gold wire, large-size chips, and thickened FPCB, backed by a 5-year warranty.

Especificações

IRC (CRI)Ra>80 / Ra>90 / Ra>95
LED QTY160 LEDs/m
PART NODL-F28A80V24-3410-*
SMD TYPE2835
UNIDADE DE CORTE8LEDs/50mm
DIMERIZÁVELYes
GRAU DE PROTEÇÃO IPIP20
LED PITCH6.2mm
LARGURA DA PCB12
ÂNGULO DE FACHO120°
COMPRIMENTO DO TRECHO5m
COPPER FOIL3oz
POWER RANGE4.8~28.8W
TIPO DE CIRCUITOC.C.
INPUT VOLTAGE24V
FLUXO LUMINOSO2230–3730 lm/m
OPERATING TEMPERATURE-25~40°C;Tc:75°C(max)

Aplicações

  • Sancas, banho de luz em paredes e perímetros — Sancas, rebaixos, detalhes de banho de luz e perímetros de teto que exigem uma linha de luz contínua e uniforme.
  • Iluminação de exposição em showrooms e hotelaria — Prateleiras, vitrines, balcões de recepção e retroiluminação de letreiros em lojas, showrooms e espaços de hotelaria.
  • Iluminação sob armários de cozinha e closets — Iluminação de tarefa em cozinhas, closets e móveis, onde a fita fica oculta e apenas a luz é vista.

Acessórios recomendados e peças compatíveis

  • DL-1201 — 25x14.5mm Wide Surface Mount LED Channel — Aluminum Profile for 12mm Strip: Accepts LED strips up to 12mm wide.
  • DL-1202 — 17.3x14.5mm Surface Mount LED Channel — Deep Aluminum Profile for 12mm Strip: Accepts LED strips up to 12mm wide.
  • DL-1204 — 25x7mm Wide Slim Surface Mount LED Channel — Dotless Aluminum Profile for 240 LEDs/m: Accepts LED strips up to 12mm wide.
  • DN-PSU-100 — 24V 100W Class-2 LED Driver · High Efficiency: Matches the 24V DC input of this strip; size the driver with at least 20% headroom over total load.
  • DN-PSU-150 — 24V 150W Class-2 LED Driver · Premium: Matches the 24V DC input of this strip; size the driver with at least 20% headroom over total load.
  • DN-PSU-60 — 24V 60W Class-2 LED Driver · Constant Voltage: Matches the 24V DC input of this strip; size the driver with at least 20% headroom over total load.
  • V1 — 5-36VDC 1-Channel * 8A RF+Push Dimming Controller | V1: Matched by input voltage range and colour channels.

Solicite um orçamento para #3410

A DENO LED é uma fabricante de fitas de LED com sede em Shenzhen e base de produção própria em Foshan. Envie-nos o comprimento do trecho, tensão, CCT/IRC e grau de proteção IP que você precisa e nossa equipe de engenharia responderá com uma ficha técnica, diagrama de fiação e preço — OEM/ODM e projetos totalmente personalizados incluídos.

Garantia
Conforme a ficha técnica do modelo
Prazo de entrega
Amostras personalizadas: 3–5 dias úteis · novo desenvolvimento: 1–3 semanas · produção em série: 1–2 semanas após aprovação da amostra
Conformidade
CE · RoHS · UL/ETL conforme o modelo e o mercado
Fio de ligação
Ouro puro 99,99%
Folha de cobre
FPCB de cobre puro 99,9%
Serviços
CCT, IRC, largura de PCB, unidade de corte e embalagem personalizadas — amostras e produção em massa de uma única fábrica.

Desempenho Fotométrico — Matriz de Eficácia CCT × IRC (CRI)

Peak measured luminous efficacy: 198.5 lm/W at 4000K, Ra 80, ErP energy class C (Grade DN (1st Tier) · 9.6W/m).

All values are measured at the stated power density and ambient 25 °C, reported as luminous efficacy in lumens per watt (lm/W), luminous flux per metre (lm/m) and the corresponding EU ErP (2019/2015) energy class.

Grade DL (2nd Tier) · 9.6W/m

Grade DL (2nd Tier) · 9.6W/m — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K144.9 lm/W1391.3 lm/mD116.2 lm/W1115.7 lm/mE———
2300 K161.3 lm/W1548.8 lm/mC129.5 lm/W1243 lm/mE104.7 lm/W1005.1 lm/mF
2700 K170.6 lm/W1637.6 lm/mC140.1 lm/W1345.3 lm/mD113.6 lm/W1090.7 lm/mE
3000 K181.7 lm/W1744 lm/mC147.5 lm/W1416.3 lm/mD119.9 lm/W1151.2 lm/mE
3500 K184.4 lm/W1770.1 lm/mC150.1 lm/W1441.3 lm/mD123.5 lm/W1185.6 lm/mE
4000 K190.3 lm/W1826.5 lm/mB153.7 lm/W1475.8 lm/mD126.9 lm/W1218 lm/mE
5000 K190 lm/W1824.4 lm/mB153.6 lm/W1474.7 lm/mD127.2 lm/W1221.1 lm/mE
6500 K174.2 lm/W1672 lm/mC147.4 lm/W1415.3 lm/mD122.3 lm/W1174.2 lm/mE

Grade DL (2nd Tier) · 14.4W/m

Grade DL (2nd Tier) · 14.4W/m — measured at 14.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K140.1 lm/W2017.7 lm/mD112.4 lm/W1618.1 lm/mE———
2300 K156 lm/W2246.2 lm/mD125.2 lm/W1802.7 lm/mE101.2 lm/W1457.6 lm/mF
2700 K164.9 lm/W2374.9 lm/mC135.5 lm/W1951.1 lm/mD109.8 lm/W1581.8 lm/mF
3000 K175.6 lm/W2529.3 lm/mC142.6 lm/W2054 lm/mD115.9 lm/W1669.5 lm/mE
3500 K178.3 lm/W2567.1 lm/mC145.2 lm/W2090.3 lm/mD119.4 lm/W1719.5 lm/mE
4000 K183.9 lm/W2648.9 lm/mC148.6 lm/W2140.3 lm/mD122.7 lm/W1766.4 lm/mE
5000 K183.7 lm/W2645.8 lm/mC148.5 lm/W2138.8 lm/mD123 lm/W1771 lm/mE
6500 K168.4 lm/W2424.9 lm/mC142.5 lm/W2052.5 lm/mD118.3 lm/W1702.8 lm/mE

Grade DL (2nd Tier) · 19.2W/m

Grade DL (2nd Tier) · 19.2W/m — measured at 19.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K135.5 lm/W2601 lm/mD108.6 lm/W2085.9 lm/mF———
2300 K150.8 lm/W2895.7 lm/mD121 lm/W2324 lm/mE97.9 lm/W1879.1 lm/mF
2700 K159.5 lm/W3061.5 lm/mD131 lm/W2515.2 lm/mE106.2 lm/W2039.1 lm/mF
3000 K169.8 lm/W3260.6 lm/mC137.9 lm/W2647.9 lm/mD112.1 lm/W2152.3 lm/mE
3500 K172.4 lm/W3309.4 lm/mC140.3 lm/W2694.7 lm/mD115.5 lm/W2216.6 lm/mE
4000 K177.9 lm/W3414.7 lm/mC143.7 lm/W2759.1 lm/mD118.6 lm/W2277.1 lm/mE
5000 K177.6 lm/W3410.8 lm/mC143.6 lm/W2757.1 lm/mD118.9 lm/W2283 lm/mE
6500 K162.8 lm/W3125.9 lm/mC137.8 lm/W2645.9 lm/mD114.3 lm/W2195.2 lm/mE

Grade DL (2nd Tier) · 22W/m

Grade DL (2nd Tier) · 22W/m — measured at 22 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K132.8 lm/W2922.3 lm/mE106.5 lm/W2343.6 lm/mF———
2300 K147.9 lm/W3253.4 lm/mD118.7 lm/W2611 lm/mE96 lm/W2111.2 lm/mF
2700 K156.3 lm/W3439.7 lm/mD128.4 lm/W2825.9 lm/mE104.1 lm/W2290.9 lm/mF
3000 K166.5 lm/W3663.3 lm/mC135.2 lm/W2974.9 lm/mD109.9 lm/W2418.1 lm/mF
3500 K169 lm/W3718.1 lm/mC137.6 lm/W3027.5 lm/mD113.2 lm/W2490.4 lm/mE
4000 K174.4 lm/W3836.5 lm/mC140.9 lm/W3099.9 lm/mD116.3 lm/W2558.4 lm/mE
5000 K174.2 lm/W3832.1 lm/mC140.8 lm/W3097.7 lm/mD116.6 lm/W2565 lm/mE
6500 K159.6 lm/W3512 lm/mD135.1 lm/W2972.7 lm/mD112.1 lm/W2466.3 lm/mE

Grade DN (1st Tier) · 9.6W/m

Grade DN (1st Tier) · 9.6W/m — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K155.6 lm/W1493.5 lm/mD131.1 lm/W1258.7 lm/mE———
2300 K169.6 lm/W1628.2 lm/mD146.2 lm/W1403.8 lm/mD118.2 lm/W1134.5 lm/mF
2700 K182.8 lm/W1754.5 lm/mC158.3 lm/W1519.6 lm/mD128.3 lm/W1231.6 lm/mE
3000 K192 lm/W1843.2 lm/mC167.1 lm/W1604.2 lm/mD135.9 lm/W1304.6 lm/mE
3500 K194.8 lm/W1870.3 lm/mC170.7 lm/W1638.6 lm/mD140.5 lm/W1348.5 lm/mE
4000 K198.5 lm/W1905.8 lm/mC171.7 lm/W1648 lm/mD141.7 lm/W1359.9 lm/mE
5000 K198.2 lm/W1902.7 lm/mC172.8 lm/W1658.4 lm/mD143.1 lm/W1373.5 lm/mE
6500 K190 lm/W1824.4 lm/mC165.1 lm/W1585.4 lm/mD137.1 lm/W1316.1 lm/mE

Grade DN (1st Tier) · 14.4W/m

Grade DN (1st Tier) · 14.4W/m — measured at 14.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K150.4 lm/W2166 lm/mD126.8 lm/W1825.5 lm/mE———
2300 K164 lm/W2361.3 lm/mD141.4 lm/W2035.8 lm/mE114.3 lm/W1645.3 lm/mF
2700 K176.7 lm/W2544.4 lm/mC153 lm/W2203.9 lm/mD124 lm/W1786.1 lm/mE
3000 K185.6 lm/W2673.1 lm/mC161.6 lm/W2326.5 lm/mD131.4 lm/W1892.1 lm/mE
3500 K188.4 lm/W2712.4 lm/mC165 lm/W2376.4 lm/mD135.8 lm/W1955.6 lm/mE
4000 K191.9 lm/W2763.9 lm/mC166 lm/W2390 lm/mD137 lm/W1972.3 lm/mE
5000 K191.6 lm/W2759.4 lm/mC167 lm/W2405.2 lm/mD138.3 lm/W1992 lm/mE
6500 K183.7 lm/W2645.8 lm/mC159.7 lm/W2299.2 lm/mD132.5 lm/W1908.7 lm/mE

Grade DN (1st Tier) · 19.2W/m

Grade DN (1st Tier) · 19.2W/m — measured at 19.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K145.4 lm/W2792.3 lm/mE122.6 lm/W2353.2 lm/mE———
2300 K158.5 lm/W3044 lm/mD136.7 lm/W2624.5 lm/mE110.5 lm/W2121 lm/mF
2700 K170.8 lm/W3280.1 lm/mD148 lm/W2841.1 lm/mD119.9 lm/W2302.5 lm/mE
3000 K179.5 lm/W3445.9 lm/mC156.2 lm/W2999.1 lm/mD127 lm/W2439.1 lm/mE
3500 K182.1 lm/W3496.7 lm/mC159.6 lm/W3063.5 lm/mD131.3 lm/W2521 lm/mE
4000 K185.6 lm/W3563 lm/mC160.5 lm/W3081.1 lm/mD132.4 lm/W2542.5 lm/mE
5000 K185.3 lm/W3557.2 lm/mC161.5 lm/W3100.6 lm/mD133.7 lm/W2567.9 lm/mE
6500 K177.6 lm/W3410.8 lm/mC154.4 lm/W2964 lm/mD128.2 lm/W2460.6 lm/mE

Grade DN (1st Tier) · 22W/m

Grade DN (1st Tier) · 22W/m — measured at 22 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K142.6 lm/W3137.2 lm/mE120.2 lm/W2643.9 lm/mE———
2300 K155.5 lm/W3420 lm/mD134 lm/W2948.6 lm/mE108.3 lm/W2383 lm/mF
2700 K167.5 lm/W3685.2 lm/mD145.1 lm/W3192 lm/mE117.6 lm/W2586.9 lm/mF
3000 K176 lm/W3871.6 lm/mC153.2 lm/W3369.5 lm/mD124.6 lm/W2740.4 lm/mE
3500 K178.6 lm/W3928.6 lm/mC156.4 lm/W3441.9 lm/mD128.7 lm/W2832.4 lm/mE
4000 K182 lm/W4003.1 lm/mC157.3 lm/W3461.6 lm/mD129.8 lm/W2856.5 lm/mE
5000 K181.7 lm/W3996.5 lm/mC158.3 lm/W3483.5 lm/mD131.1 lm/W2885 lm/mE
6500 K174.2 lm/W3832.1 lm/mC151.4 lm/W3330.1 lm/mD125.7 lm/W2764.5 lm/mE

Grade KE (3rd Tier) · 9.6W/m

Grade KE (3rd Tier) · 9.6W/m — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K123 lm/W1180.4 lm/mE98.5 lm/W945.6 lm/mF———
2300 K137 lm/W1315.1 lm/mD109.7 lm/W1053.1 lm/mF88.7 lm/W851.7 lm/mF
2700 K147.7 lm/W1418.4 lm/mD119 lm/W1142.9 lm/mE96.5 lm/W926.8 lm/mF
3000 K155.1 lm/W1489.4 lm/mD125.8 lm/W1207.6 lm/mE102.3 lm/W982.1 lm/mF
3500 K157.4 lm/W1511.3 lm/mD128.3 lm/W1231.6 lm/mE105.6 lm/W1013.4 lm/mF
4000 K162.1 lm/W1556.2 lm/mC131 lm/W1257.7 lm/mE108.2 lm/W1038.5 lm/mF
5000 K161.8 lm/W1553 lm/mC131 lm/W1257.7 lm/mE108.4 lm/W1040.6 lm/mF
6500 K155.1 lm/W1489.4 lm/mD125.8 lm/W1207.6 lm/mE104.4 lm/W1002 lm/mF

Grade KE (3rd Tier) · 14.4W/m

Grade KE (3rd Tier) · 14.4W/m — measured at 14.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K118.9 lm/W1711.9 lm/mE95.2 lm/W1371.4 lm/mF———
2300 K132.4 lm/W1907.2 lm/mE106.1 lm/W1527.3 lm/mF85.8 lm/W1235.1 lm/mF
2700 K142.8 lm/W2057 lm/mD115.1 lm/W1657.4 lm/mE93.3 lm/W1344.1 lm/mF
3000 K150 lm/W2160 lm/mD121.6 lm/W1751.3 lm/mE98.9 lm/W1424.3 lm/mF
3500 K152.2 lm/W2191.8 lm/mD124 lm/W1786.1 lm/mE102.1 lm/W1469.7 lm/mF
4000 K156.7 lm/W2256.8 lm/mD126.7 lm/W1823.9 lm/mE104.6 lm/W1506.1 lm/mF
5000 K156.4 lm/W2252.3 lm/mD126.7 lm/W1823.9 lm/mE104.8 lm/W1509.1 lm/mF
6500 K150 lm/W2160 lm/mD121.6 lm/W1751.3 lm/mE100.9 lm/W1453.1 lm/mF

Grade KE (3rd Tier) · 19.2W/m

Grade KE (3rd Tier) · 19.2W/m — measured at 19.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K114.9 lm/W2206.9 lm/mE92.1 lm/W1767.9 lm/mF———
2300 K128.1 lm/W2458.6 lm/mE102.5 lm/W1968.8 lm/mF82.9 lm/W1592.2 lm/mG
2700 K138.1 lm/W2651.8 lm/mD111.3 lm/W2136.6 lm/mE90.2 lm/W1732.7 lm/mF
3000 K145 lm/W2784.5 lm/mD117.6 lm/W2257.6 lm/mE95.6 lm/W1836.1 lm/mF
3500 K147.2 lm/W2825.4 lm/mD119.9 lm/W2302.5 lm/mE98.7 lm/W1894.7 lm/mF
4000 K151.5 lm/W2909.3 lm/mD122.5 lm/W2351.3 lm/mE101.1 lm/W1941.5 lm/mF
5000 K151.2 lm/W2903.5 lm/mD122.5 lm/W2351.3 lm/mE101.3 lm/W1945.4 lm/mF
6500 K145 lm/W2784.5 lm/mD117.6 lm/W2257.6 lm/mE97.6 lm/W1873.2 lm/mF

Grade KE (3rd Tier) · 22W/m

Grade KE (3rd Tier) · 22W/m — measured at 22 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K112.7 lm/W2479.5 lm/mE90.3 lm/W1986.2 lm/mF———
2300 K125.6 lm/W2762.3 lm/mE100.5 lm/W2212 lm/mF81.3 lm/W1788.9 lm/mG
2700 K135.4 lm/W2979.3 lm/mD109.1 lm/W2400.6 lm/mF88.5 lm/W1946.8 lm/mF
3000 K142.2 lm/W3128.4 lm/mD115.3 lm/W2536.5 lm/mE93.8 lm/W2062.9 lm/mF
3500 K144.3 lm/W3174.4 lm/mD117.6 lm/W2586.9 lm/mE96.8 lm/W2128.7 lm/mF
4000 K148.6 lm/W3268.7 lm/mD120.1 lm/W2641.7 lm/mE99.2 lm/W2181.3 lm/mF
5000 K148.3 lm/W3262.1 lm/mD120.1 lm/W2641.7 lm/mE99.4 lm/W2185.7 lm/mF
6500 K142.2 lm/W3128.4 lm/mD115.3 lm/W2536.5 lm/mE95.7 lm/W2104.6 lm/mF

High-Power LED Strip: Heat Dissipation & Aluminum Channel Guide

At up to 22W/m, 3410 is a high-power SMD LED strip. Above roughly 14.4W/m the tape can no longer shed its own heat through the FPC alone — an aluminum channel is part of the luminaire, not an accessory.

Why high-wattage strips need a heat sink

  • Aluminum conducts heat roughly 30× faster than the plastics, MDF or gypsum a strip is usually stuck to, so a bare high-power run traps heat under the tape.
  • LED lifetime (LM-80 / TM-21) is driven by solder-point temperature Tc. Keeping Tc inside the datasheet limit — DENO strips are rated Tc ≤ 75°C — is what preserves the rated L70 lifetime and colour stability.
  • Never run 14.4W/m or more coiled on the reel, inside a sealed plastic diffuser, or directly on wood, wallpaper or foam.

Sizing rule: FPC width vs channel inner width

  • Channel inner width ≥ FPC width + 2mm. This strip is 12mm wide, so it needs at least 14mm of inner width.
  • The 2mm clearance absorbs extrusion tolerance and lets the tape be seated or replaced without scraping the side walls or the wiring.
  • A frosted or opal PC cover then diffuses the higher lumen output into an even, dot-free line instead of visible hot spots.

Aluminum channels that fit this strip

Recommended LED Channels

Mount this LED strip in a DENO LED aluminum profile for heat dissipation, physical protection and diffused, dot-free output.

This strip is 12mm wide, so it needs a channel with at least 14mm inner width (12mm + 2mm clearance). Every profile below meets that.

Modelos relacionados nesta série

See every model in SMD LED Strip Series or narrow to High Efficiency. Compare wattage, lumen output and run length in the ProCalc parameter library, or request OEM/ODM pricing on the custom manufacturing page.

Perguntas Frequentes

Quais dados estão registrados para o modelo 3410?

tensão: 24V; largura da PCB: 12; LEDs: 160 LEDs/m; encapsulamento: 2835; unidade de corte: 8LEDs/50mm; cobre: 3oz. Consulte a ficha técnica para a configuração do pedido.

Como confirmar a potência e a alimentação do modelo 3410?

Confirme a configuração na tabela de parâmetros do produto antes de dimensionar a fonte. Não extrapole comprimentos, corrente ou condições térmicas sem validação da instalação.

Como solicitar a configuração do modelo 3410?

Informe o modelo e as necessidades do projeto no pedido de orçamento. Temperatura de cor, proteção, amostra e prazo devem ser confirmados para a configuração solicitada.

Engineering & selection guide

Bending limits, IP selection, voltage drop, cutting and the full buyer Q&A for this family are kept on the series page.