DENO LED Lighting

Fita de LED Ultraestreita 2835 (#9496)

5mm · 12V · 120LEDs · 25cut

Model: 9496

9496 Fita de LED Ultraestreita 2835 — 12V, corte a cada 25 mm, FPCB de 5 mm, LEDs 2835, 120 LEDs/m, IP20Desenho dimensional 9496 Fita de LED Ultraestreita 2835 — FPCB de 5 mm, corte a cada 25 mm, 12V9496 Fita de LED Ultraestreita 2835 — 12V, corte a cada 25 mm, FPCB de 5 mm, LEDs 2835, 120 LEDs/m, IP20 (vista 3)9496 Fita de LED Ultraestreita 2835 — 12V, corte a cada 25 mm, FPCB de 5 mm, LEDs 2835, 120 LEDs/m, IP20 (vista 4)9496 Fita de LED Ultraestreita 2835 — 12V, corte a cada 25 mm, FPCB de 5 mm, LEDs 2835, 120 LEDs/m, IP20 (vista 5)

Visão Geral

5mm | 12V | 120LEDs | corte de 25 | #9496 | Fita de LED Ultraestreita 2835 faz parte da série de Fitas SMD Ultraestreitas da DENO, desenvolvida para aplicações com Fita de LED ultraestreita. Especificações principais: 2835, 120 LEDs/m, 12V, PCB de 5mm, FPCB com cobre de 3oz, corte a cada 3LEDs/25mm. Cada rolo é produzido na linha rolo a rolo da DENO com FPCB de cobre de pureza 99.9% e é fornecido em conformidade com CE, UL e RoHS para projetos de arquitetura, varejo e hotelaria. Configurações OEM e ODM de comprimento, temperatura de cor e impermeabilização estão disponíveis mediante solicitação.

Descrição

Esta Fita de LED 2835 ultraestreita de 5mm foi projetada especificamente para integração harmoniosa em Perfis de Alumínio estreitos e iluminação de frestas arquiteturais reduzidas. Com 120 LEDs por metro e espaçamento de 8.3mm, o circuito de tensão constante de 12V permite cortes precisos em intervalos de 25mm. Construída com folha de cobre reforçada de 3oz, a PCB mantém estabilidade térmica superior em temperaturas de operação de -25°C a 40°C. A capacidade de dimerização completa e o amplo ângulo de abertura de 120 graus tornam este modelo ideal para fornecimento de projetos no atacado e instalações de iluminação de armários. Com diâmetro mínimo de curvatura de 60mm e comprimento contínuo de 5M, nossa fábrica oferece fabricação OEM confiável para luminárias compactas especializadas.

Ultra Narrow Led Strip built for ultra-narrow smd strips projects.

Especificações

LED QTY120 LEDs/m
PART NODL-F28A60V12-9496-*
SMD TYPE2835
UNIDADE DE CORTE3LEDs/25mm
DIMERIZÁVELYes
GRAU DE PROTEÇÃO IPIP20
LED PITCH8.3mm
LARGURA DA PCB5mm
ÂNGULO DE FACHO120°
COMPRIMENTO DO TRECHO5M
COPPER FOIL3oz
ON OFF TIMES10000(test times)
POWER RANGE2.4~14.4W
TIPO DE CIRCUITOC.V.
INPUT VOLTAGE12V
MIN BEND DIAMETERΦ60mm
OPERATING TEMPERATURE-25~40°C;Tc:75°C(max)

Aplicações

  • Sancas, banho de luz em paredes e perímetros — Sancas, rebaixos, detalhes de banho de luz e perímetros de teto que exigem uma linha de luz contínua e uniforme.
  • Iluminação de exposição em showrooms e hotelaria — Prateleiras, vitrines, balcões de recepção e retroiluminação de letreiros em lojas, showrooms e espaços de hotelaria.
  • Iluminação sob armários de cozinha e closets — Iluminação de tarefa em cozinhas, closets e móveis, onde a fita fica oculta e apenas a luz é vista.
  • Perfis ultraestreitos de 5 mm e frisos de sombra — Cabe em frisos de sombra, perfis finos e rasgos de marcenaria que não comportam uma fita padrão de 8–10 mm.

Acessórios recomendados e peças compatíveis

  • DL-0809HX-F — 8.89x7.79mm Mini Recessed LED Channel with Flange — Trimless Aluminum Profile for 5mm Strip: Accepts LED strips up to 5mm wide.
  • DL-0909HX-M — 9x9mm Magnetic LED Channel — Tool-Free Aluminum Profile for Shelf Lighting: Accepts LED strips up to 5mm wide.
  • DL-1010HX-V — 10x10mm V Shape Corner LED Channel — 45 Degree Aluminum Profile for Cabinets: Accepts LED strips up to 5mm wide.
  • V1 — 5-36VDC 1-Channel * 8A RF+Push Dimming Controller | V1: Matched by input voltage range and colour channels.

Solicite um orçamento para #9496

A DENO LED é uma fabricante de fitas de LED com sede em Shenzhen e base de produção própria em Foshan. Envie-nos o comprimento do trecho, tensão, CCT/IRC e grau de proteção IP que você precisa e nossa equipe de engenharia responderá com uma ficha técnica, diagrama de fiação e preço — OEM/ODM e projetos totalmente personalizados incluídos.

Garantia
Conforme a ficha técnica do modelo
Prazo de entrega
Amostras personalizadas: 3–5 dias úteis · novo desenvolvimento: 1–3 semanas · produção em série: 1–2 semanas após aprovação da amostra
Conformidade
CE · RoHS · UL/ETL conforme o modelo e o mercado
Fio de ligação
Ouro puro 99,99%
Folha de cobre
FPCB de cobre puro 99,9%
Serviços
CCT, IRC, largura de PCB, unidade de corte e embalagem personalizadas — amostras e produção em massa de uma única fábrica.

Desempenho Fotométrico — Matriz de Eficácia CCT × IRC (CRI)

Peak measured luminous efficacy: 165.5 lm/W at 4000K, Ra 80, ErP energy class D (Grade DN (1st Tier)).

All values are measured at the stated power density and ambient 25 °C, reported as luminous efficacy in lumens per watt (lm/W), luminous flux per metre (lm/m) and the corresponding EU ErP (2019/2015) energy class.

Grade DL (2nd Tier)

Grade DL (2nd Tier) — measured at 4.8 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K118 lm/W566.5 lm/mE94.4 lm/W453.3 lm/mF———
2300 K131.4 lm/W630.9 lm/mE105.3 lm/W505.3 lm/mF85.3 lm/W409.4 lm/mF
2700 K138.4 lm/W664.3 lm/mD113.8 lm/W546.5 lm/mE92.3 lm/W443 lm/mF
3000 K147.9 lm/W710.1 lm/mD119.9 lm/W575.3 lm/mE97.4 lm/W467.7 lm/mF
3500 K150.2 lm/W720.9 lm/mD122 lm/W585.6 lm/mE100.4 lm/W482.2 lm/mF
4000 K154.9 lm/W743.6 lm/mD124.9 lm/W599.5 lm/mE103.1 lm/W495 lm/mF
5000 K154.8 lm/W743 lm/mD124.9 lm/W599.5 lm/mE103 lm/W494.4 lm/mF
6500 K141.6 lm/W679.7 lm/mD119.7 lm/W574.8 lm/mE99.4 lm/W477.1 lm/mF

Grade DL (2nd Tier)

Grade DL (2nd Tier) — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K114.1 lm/W1095.5 lm/mE91.3 lm/W876.6 lm/mF———
2300 K127.1 lm/W1219.9 lm/mE101.8 lm/W977.1 lm/mF82.4 lm/W791 lm/mG
2700 K133.8 lm/W1284.6 lm/mE110.1 lm/W1056.7 lm/mE89.2 lm/W856.7 lm/mF
3000 K143 lm/W1373.1 lm/mD115.9 lm/W1112.4 lm/mE94.2 lm/W904.5 lm/mF
3500 K145.2 lm/W1394 lm/mD118 lm/W1132.3 lm/mE97.1 lm/W932.3 lm/mF
4000 K149.8 lm/W1437.8 lm/mD120.7 lm/W1159.2 lm/mE99.7 lm/W957.2 lm/mF
5000 K149.7 lm/W1436.8 lm/mD120.7 lm/W1159.2 lm/mE99.6 lm/W956.2 lm/mF
6500 K136.9 lm/W1314.4 lm/mD115.8 lm/W1111.4 lm/mE96.1 lm/W922.6 lm/mF

Grade DL (2nd Tier)

Grade DL (2nd Tier) — measured at 14.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K110.3 lm/W1588.8 lm/mE88.3 lm/W1271.3 lm/mF———
2300 K122.9 lm/W1769.2 lm/mE98.4 lm/W1417.1 lm/mF79.7 lm/W1147.7 lm/mG
2700 K129.4 lm/W1863 lm/mE106.4 lm/W1532.5 lm/mF86.3 lm/W1242.5 lm/mF
3000 K138.3 lm/W1991.4 lm/mD112 lm/W1613.3 lm/mE91.1 lm/W1311.7 lm/mF
3500 K140.4 lm/W2021.7 lm/mD114 lm/W1642.2 lm/mE93.9 lm/W1352.1 lm/mF
4000 K144.8 lm/W2085.2 lm/mD116.7 lm/W1681.1 lm/mE96.4 lm/W1388.2 lm/mF
5000 K144.7 lm/W2083.7 lm/mD116.7 lm/W1681.1 lm/mE96.3 lm/W1386.7 lm/mF
6500 K132.4 lm/W1906.3 lm/mE111.9 lm/W1611.9 lm/mE92.9 lm/W1337.8 lm/mF

Grade DN (1st Tier)

Grade DN (1st Tier) — measured at 4.8 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K129.7 lm/W622.6 lm/mE109.1 lm/W523.8 lm/mF———
2300 K141.4 lm/W678.7 lm/mE121.8 lm/W584.6 lm/mE98.6 lm/W473.3 lm/mF
2700 K152.4 lm/W731.7 lm/mD131.8 lm/W632.4 lm/mE106.8 lm/W512.5 lm/mF
3000 K160.1 lm/W768.3 lm/mD139.1 lm/W667.9 lm/mE113.2 lm/W543.4 lm/mF
3500 K162.4 lm/W779.6 lm/mD142.1 lm/W682.3 lm/mE117.1 lm/W561.9 lm/mF
4000 K165.5 lm/W794.5 lm/mD143 lm/W686.4 lm/mE118 lm/W566.5 lm/mF
5000 K165.3 lm/W793.5 lm/mD143.9 lm/W690.6 lm/mE118.7 lm/W569.8 lm/mF
6500 K158.4 lm/W760.5 lm/mD137.5 lm/W660.2 lm/mE114.2 lm/W548.2 lm/mF

Grade DN (1st Tier)

Grade DN (1st Tier) — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K125.4 lm/W1204 lm/mE105.5 lm/W1012.9 lm/mF———
2300 K136.7 lm/W1312.4 lm/mE117.7 lm/W1130.3 lm/mF95.4 lm/W915.8 lm/mF
2700 K147.4 lm/W1414.9 lm/mD127.4 lm/W1222.9 lm/mE103.2 lm/W991 lm/mF
3000 K154.7 lm/W1485.6 lm/mD134.5 lm/W1291.5 lm/mE109.5 lm/W1050.7 lm/mF
3500 K157 lm/W1507.4 lm/mD137.4 lm/W1319.4 lm/mE113.2 lm/W1086.6 lm/mF
4000 K160 lm/W1536.3 lm/mD138.3 lm/W1327.4 lm/mE114.1 lm/W1095.5 lm/mF
5000 K159.8 lm/W1534.3 lm/mD139.1 lm/W1335.3 lm/mE114.8 lm/W1102.1 lm/mF
6500 K153.2 lm/W1470.6 lm/mD133 lm/W1276.6 lm/mE110.4 lm/W1059.8 lm/mF

Grade DN (1st Tier)

Grade DN (1st Tier) — measured at 14.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K121.3 lm/W1746.1 lm/mE102 lm/W1469 lm/mF———
2300 K132.2 lm/W1903.4 lm/mE113.8 lm/W1639.3 lm/mF92.2 lm/W1327.7 lm/mF
2700 K142.5 lm/W2052 lm/mE123.2 lm/W1773.5 lm/mE99.8 lm/W1437.3 lm/mF
3000 K149.6 lm/W2154.5 lm/mD130.1 lm/W1873.1 lm/mE105.8 lm/W1523.8 lm/mF
3500 K151.8 lm/W2186.2 lm/mD132.9 lm/W1913.5 lm/mE109.4 lm/W1575.8 lm/mF
4000 K154.7 lm/W2228.1 lm/mD133.7 lm/W1925 lm/mE110.3 lm/W1588.8 lm/mF
5000 K154.5 lm/W2225.2 lm/mD134.5 lm/W1936.6 lm/mE110.9 lm/W1597 lm/mF
6500 K148.1 lm/W2132.8 lm/mD128.6 lm/W1851.4 lm/mE106.7 lm/W1536.5 lm/mF

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 4.8 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K96.5 lm/W463.1 lm/mF77 lm/W369.5 lm/mG———
2300 K107.5 lm/W516.1 lm/mF85.8 lm/W411.7 lm/mF69.5 lm/W333.6 lm/mG
2700 K115.9 lm/W556.2 lm/mE93.1 lm/W446.6 lm/mF75.5 lm/W362.3 lm/mG
3000 K121.7 lm/W584 lm/mE98.4 lm/W472.4 lm/mF80.1 lm/W384.4 lm/mG
3500 K123.5 lm/W592.8 lm/mE100.3 lm/W481.6 lm/mF82.5 lm/W396.2 lm/mG
4000 K127.1 lm/W610.3 lm/mE102.5 lm/W491.9 lm/mF84.6 lm/W406 lm/mG
5000 K126.9 lm/W609.2 lm/mE102.5 lm/W491.9 lm/mF84.6 lm/W406.1 lm/mG
6500 K121.7 lm/W584 lm/mE98.4 lm/W472.4 lm/mF81.7 lm/W392.2 lm/mG

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K93.3 lm/W895.5 lm/mF74.4 lm/W714.4 lm/mG———
2300 K104 lm/W998 lm/mF82.9 lm/W796 lm/mG67.2 lm/W645.1 lm/mG
2700 K112 lm/W1075.6 lm/mE90 lm/W863.7 lm/mF73 lm/W700.5 lm/mG
3000 K117.6 lm/W1129.3 lm/mE95.1 lm/W913.4 lm/mF77.4 lm/W743.3 lm/mG
3500 K119.4 lm/W1146.3 lm/mE97 lm/W931.3 lm/mF79.8 lm/W766.2 lm/mG
4000 K122.9 lm/W1180.1 lm/mE99.1 lm/W951.2 lm/mF81.8 lm/W785.1 lm/mG
5000 K122.7 lm/W1178.1 lm/mE99.1 lm/W951.2 lm/mF81.7 lm/W784.3 lm/mG
6500 K117.6 lm/W1129.3 lm/mE95.1 lm/W913.4 lm/mF79 lm/W758.4 lm/mG

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 14.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K90.2 lm/W1298.7 lm/mF72 lm/W1036.1 lm/mG———
2300 K100.5 lm/W1447.4 lm/mF80.2 lm/W1154.4 lm/mG64.9 lm/W934.6 lm/mG
2700 K108.3 lm/W1559.9 lm/mF87 lm/W1252.6 lm/mF70.5 lm/W1015.9 lm/mG
3000 K113.7 lm/W1637.8 lm/mE92 lm/W1324.7 lm/mF74.9 lm/W1077.9 lm/mG
3500 K115.4 lm/W1662.4 lm/mE93.8 lm/W1350.7 lm/mF77.2 lm/W1111.1 lm/mG
4000 K118.9 lm/W1711.4 lm/mE95.8 lm/W1379.5 lm/mF79.1 lm/W1138.6 lm/mG
5000 K118.6 lm/W1708.6 lm/mE95.8 lm/W1379.5 lm/mF79 lm/W1137.6 lm/mG
6500 K113.7 lm/W1637.8 lm/mE92 lm/W1324.7 lm/mF76.4 lm/W1100.2 lm/mG

High-Power LED Strip: Heat Dissipation & Aluminum Channel Guide

At up to 14.4W/m, 9496 is a high-power SMD LED strip. Above roughly 14.4W/m the tape can no longer shed its own heat through the FPC alone — an aluminum channel is part of the luminaire, not an accessory.

Why high-wattage strips need a heat sink

  • Aluminum conducts heat roughly 30× faster than the plastics, MDF or gypsum a strip is usually stuck to, so a bare high-power run traps heat under the tape.
  • LED lifetime (LM-80 / TM-21) is driven by solder-point temperature Tc. Keeping Tc inside the datasheet limit — DENO strips are rated Tc ≤ 75°C — is what preserves the rated L70 lifetime and colour stability.
  • Never run 14.4W/m or more coiled on the reel, inside a sealed plastic diffuser, or directly on wood, wallpaper or foam.

Sizing rule: FPC width vs channel inner width

  • Channel inner width ≥ FPC width + 2mm. This strip is 5mm wide, so it needs at least 7mm of inner width.
  • The 2mm clearance absorbs extrusion tolerance and lets the tape be seated or replaced without scraping the side walls or the wiring.
  • A frosted or opal PC cover then diffuses the higher lumen output into an even, dot-free line instead of visible hot spots.

Aluminum channels that fit this strip

Recommended LED Channels

Mount this LED strip in a DENO LED aluminum profile for heat dissipation, physical protection and diffused, dot-free output.

This strip is 5mm wide, so it needs a channel with at least 7mm inner width (5mm + 2mm clearance). Every profile below meets that.

Modelos relacionados nesta série

See every model in SMD LED Strip Series or narrow to Ultra Narrow. Compare wattage, lumen output and run length in the ProCalc parameter library, or request OEM/ODM pricing on the custom manufacturing page.

Perguntas Frequentes

Quais dados estão registrados para o modelo 9496?

tensão: 12V; largura da PCB: 5mm; LEDs: 120 LEDs/m; encapsulamento: 2835; unidade de corte: 3LEDs/25mm; cobre: 3oz. Consulte a ficha técnica para a configuração do pedido.

Como confirmar a potência e a alimentação do modelo 9496?

Confirme a configuração na tabela de parâmetros do produto antes de dimensionar a fonte. Não extrapole comprimentos, corrente ou condições térmicas sem validação da instalação.

Como solicitar a configuração do modelo 9496?

Informe o modelo e as necessidades do projeto no pedido de orçamento. Temperatura de cor, proteção, amostra e prazo devem ser confirmados para a configuração solicitada.

Engineering & selection guide