Model: 5274

5274 15mm | 24V | 140LEDs | 100mm/corte | #5274 | Fita de LED 2835 Multilinha de Corrente Constante para Trechos Longos — 24V, cuttable every 100mm, 15mm FPCB width, 2835 LEDs, 140 LEDs/m, 1900–6500K

Visão Geral

15mm | 24V | 140LEDs | 100mm/corte | #5274 | A Fita de LED 2835 de Corrente Constante Ultralonga com Múltiplas Fileiras faz parte da série de Fitas SMD Ultralongas da DENO, desenvolvida para trechos ultralongos de Fita de LED. Principais especificações: 2835, 140 LEDs/m, 24V, PCB de 15mm, FPCB com cobre de 3oz, corte a cada 14LEDs/100mm. Cada rolo é produzido na linha rolo a rolo da DENO com FPCB de cobre com pureza de 99.9% e fornecido em conformidade com CE, UL e RoHS para projetos arquitetônicos, de varejo e de hotelaria. Configurações OEM e ODM de comprimento, temperatura de cor e impermeabilização estão disponíveis sob consulta.

Descrição

Projetada com um circuito de corrente constante e 140 LEDs por metro, esta Fita de LED 2835 mantém o brilho uniforme ao longo de trechos extensos. A robusta PCB de 15mm de largura possui folha de cobre de 3oz para fornecer distribuição estável de energia em 24V em trechos únicos de até 10 metros. Os chips SMD 2835 dimerizáveis oferecem um amplo ângulo de abertura de 120 graus, com intervalos de corte precisos a cada 100mm para instalações flexíveis de iluminação arquitetônica no local. Ideal para iluminação comercial de sancas, a DENO oferece comprimentos personalizados OEM diretamente da fábrica, com opções de Temperatura de Cor (CCT) sob medida para fornecimento de projetos no atacado.

We use 99.99% gold wire, large-size chips, and thickened FPCB, backed by a 5-year warranty.

Especificações

CCT (K)1900–6500K
CRIRa≥80
POWER (W/M)14.4 W/m
LED QTY140 LEDs/m
PART NODL-F28A70V24-5274-*
SMD TYPE2835
CUTTABLE UNIT14LEDs/100mm
DIMMABLEYes
IP RATINGIP20
LED PITCH14.2mm
PCB WIDTH15mm
BEAM ANGLE120°
RUN LENGTH10m
COPPER FOIL3oz
POWER RANGE2.4~24W
CIRCUIT TYPEC.C.
INPUT VOLTAGE24V
LUMINOUS FLUX1710–2255 lm/m

Aplicações

  • Cove, wall-wash & perimeter lighting — Coves, recesses, wall-wash details and ceiling perimeters where a continuous, uniform line of light is required.
  • Showroom & hospitality display lighting — Shelving, display cases, reception desks and signage backlighting in shops, showrooms and hospitality spaces.
  • Kitchen & wardrobe under-cabinet lighting — Kitchen, wardrobe and furniture task lighting where the strip stays hidden and only the light is seen.

Acessórios recomendados e peças compatíveis

  • DL-2001 — 30x9.7mm Ultra-Slim Surface LED Channel — Low Profile Aluminum Strip Housing: Accepts LED strips up to 15mm wide.
  • DL-2002 — 20x02mm Ultra-Slim Surface LED Channel — Flat Aluminum LED Strip Profile: Accepts LED strips up to 15mm wide.
  • DL-2010 — 20x10mm Wide Surface Mount LED Channel — Dotless Aluminum Profile for 240 LEDs/m: Accepts LED strips up to 15mm wide.
  • DN-PSU-100 — 24V 100W Class-2 LED Driver · High Efficiency: Matches the 24V DC input of this strip; size the driver with at least 20% headroom over total load.
  • DN-PSU-150 — 24V 150W Class-2 LED Driver · Premium: Matches the 24V DC input of this strip; size the driver with at least 20% headroom over total load.
  • DN-PSU-60 — 24V 60W Class-2 LED Driver · Constant Voltage: Matches the 24V DC input of this strip; size the driver with at least 20% headroom over total load.
  • V1 — 5-36VDC 1-Channel * 8A RF+Push Dimming Controller | V1: Matched by input voltage range and colour channels.

Solicite um orçamento para #5274

A DENO LED é uma fabricante de fitas de LED com sede em Shenzhen e base de produção própria em Foshan. Envie-nos o comprimento do trecho, tensão, CCT/IRC e grau de proteção IP que você precisa e nossa equipe de engenharia responderá com uma ficha técnica, diagrama de fiação e preço — OEM/ODM e projetos totalmente personalizados incluídos.

Garantia
5 anos
Prazo de entrega
Placas padrão: amostras a partir de 1 dia útil · personalizadas: 3–5 dias úteis · nova FPCB: 1–3 semanas · produção 1–2 semanas após aprovação da amostra
Conformidade
CE · ETL · UL · RoHS
Fio de ligação
Ouro puro 99,99%
Folha de cobre
FPCB de cobre puro 99,9%
Serviços
CCT, IRC, largura de PCB, unidade de corte e embalagem personalizadas — amostras e produção em massa de uma única fábrica.

Desempenho Fotométrico — Matriz de Eficácia CCT × IRC (CRI)

Peak measured luminous efficacy: 179.6 lm/W at 4000K, Ra 80, ErP energy class C (Grade DN (1st Tier)).

All values are measured at the stated power density and ambient 25 °C, reported as luminous efficacy in lumens per watt (lm/W), luminous flux per metre (lm/m) and the corresponding EU ErP (2019/2015) energy class.

Grade DN (1st Tier)

Grade DN (1st Tier) — measured at 4.8 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K140.8 lm/W675.7 lm/mE118.6 lm/W569.2 lm/mF———
2300 K153.4 lm/W736.4 lm/mD132.3 lm/W634.9 lm/mE107.1 lm/W514.1 lm/mF
2700 K165.4 lm/W793.9 lm/mD143.1 lm/W686.9 lm/mE116 lm/W557 lm/mF
3000 K173.7 lm/W833.7 lm/mC151.1 lm/W725.1 lm/mD122.9 lm/W590.1 lm/mE
3500 K176.3 lm/W846.4 lm/mC154.4 lm/W740.9 lm/mD127.1 lm/W610 lm/mE
4000 K179.6 lm/W862.2 lm/mC155.2 lm/W745 lm/mD128.1 lm/W615.1 lm/mE
5000 K179.3 lm/W860.7 lm/mC156.3 lm/W750.1 lm/mD128.9 lm/W618.7 lm/mE
6500 K172 lm/W825.5 lm/mD149.4 lm/W717 lm/mD124 lm/W595.2 lm/mE

Grade DN (1st Tier)

Grade DN (1st Tier) — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K136.1 lm/W1306.6 lm/mE114.7 lm/W1100.7 lm/mF———
2300 K148.3 lm/W1423.9 lm/mD127.9 lm/W1227.8 lm/mE103.6 lm/W994.6 lm/mF
2700 K159.9 lm/W1535.2 lm/mD138.4 lm/W1328.3 lm/mE112.2 lm/W1077 lm/mF
3000 K167.9 lm/W1612.1 lm/mD146.1 lm/W1402.2 lm/mD118.9 lm/W1141.1 lm/mE
3500 K170.5 lm/W1636.7 lm/mD149.2 lm/W1432.8 lm/mD122.9 lm/W1179.5 lm/mE
4000 K173.7 lm/W1667.3 lm/mC150.1 lm/W1440.6 lm/mD123.9 lm/W1189.4 lm/mE
5000 K173.4 lm/W1664.3 lm/mC151.1 lm/W1450.5 lm/mD124.7 lm/W1197.1 lm/mE
6500 K166.3 lm/W1596.3 lm/mD144.4 lm/W1386.4 lm/mE119.9 lm/W1151 lm/mE

Grade DN (1st Tier)

Grade DN (1st Tier) — measured at 14.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K131.6 lm/W1895 lm/mE110.9 lm/W1596.3 lm/mF———
2300 K143.4 lm/W2065 lm/mE123.7 lm/W1780.6 lm/mE100.2 lm/W1442.9 lm/mF
2700 K154.6 lm/W2226.5 lm/mD133.8 lm/W1926.4 lm/mE108.5 lm/W1562 lm/mF
3000 K162.4 lm/W2338 lm/mD141.2 lm/W2033.6 lm/mE114.9 lm/W1654.9 lm/mF
3500 K164.8 lm/W2373.7 lm/mD144.3 lm/W2077.9 lm/mE118.8 lm/W1710.6 lm/mE
4000 K167.9 lm/W2418 lm/mD145.1 lm/W2089.3 lm/mE119.8 lm/W1724.9 lm/mE
5000 K167.6 lm/W2413.7 lm/mD146.1 lm/W2103.6 lm/mD120.5 lm/W1735.2 lm/mE
6500 K160.8 lm/W2315.1 lm/mD139.6 lm/W2010.7 lm/mE115.9 lm/W1669 lm/mF

Grade DN (1st Tier)

Grade DN (1st Tier) — measured at 19.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K127.2 lm/W2442.8 lm/mE107.2 lm/W2057.8 lm/mF———
2300 K138.6 lm/W2662.1 lm/mE119.6 lm/W2295.5 lm/mE96.8 lm/W1858.6 lm/mF
2700 K149.5 lm/W2870.2 lm/mD129.3 lm/W2483.4 lm/mE104.9 lm/W2013.6 lm/mF
3000 K157 lm/W3013.9 lm/mD136.5 lm/W2621.5 lm/mE111.1 lm/W2133.3 lm/mF
3500 K159.4 lm/W3060 lm/mD139.5 lm/W2678.6 lm/mE114.9 lm/W2205.2 lm/mF
4000 K162.3 lm/W3117.1 lm/mD140.3 lm/W2693.4 lm/mE115.8 lm/W2223.6 lm/mF
5000 K162.1 lm/W3111.6 lm/mD141.2 lm/W2711.8 lm/mE116.5 lm/W2236.8 lm/mF
6500 K155.4 lm/W2984.5 lm/mD135 lm/W2592.1 lm/mE112.1 lm/W2152.3 lm/mF

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 4.8 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K116.8 lm/W560.8 lm/mE93.6 lm/W449.2 lm/mF———
2300 K130.3 lm/W625.4 lm/mE104.3 lm/W500.7 lm/mF84.5 lm/W405.6 lm/mG
2700 K140.4 lm/W673.8 lm/mD113.1 lm/W542.9 lm/mE91.7 lm/W440.1 lm/mF
3000 K147.5 lm/W708 lm/mD119.6 lm/W574 lm/mE97.2 lm/W466.5 lm/mF
3500 K149.6 lm/W718.1 lm/mD121.9 lm/W585.2 lm/mE100.3 lm/W481.3 lm/mF
4000 K154.1 lm/W739.5 lm/mD124.5 lm/W597.4 lm/mE102.8 lm/W493.5 lm/mF
5000 K153.9 lm/W738.5 lm/mD124.5 lm/W597.4 lm/mE102.7 lm/W493 lm/mF
6500 K147.5 lm/W708 lm/mD119.5 lm/W573.5 lm/mE99.2 lm/W476.2 lm/mF

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K113 lm/W1084.3 lm/mE90.5 lm/W868.6 lm/mF———
2300 K126 lm/W1209.4 lm/mE100.8 lm/W968.1 lm/mF81.7 lm/W784.3 lm/mG
2700 K135.7 lm/W1303 lm/mD109.4 lm/W1049.9 lm/mF88.6 lm/W850.9 lm/mF
3000 K142.6 lm/W1369 lm/mD115.6 lm/W1109.9 lm/mE94 lm/W902.1 lm/mF
3500 K144.7 lm/W1388.7 lm/mD117.9 lm/W1131.6 lm/mE96.9 lm/W930.7 lm/mF
4000 K149 lm/W1430 lm/mD120.3 lm/W1155.2 lm/mE99.4 lm/W954.3 lm/mF
5000 K148.8 lm/W1428.1 lm/mD120.3 lm/W1155.2 lm/mE99.3 lm/W953.3 lm/mF
6500 K142.6 lm/W1369 lm/mD115.5 lm/W1109 lm/mE95.9 lm/W920.6 lm/mF

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 14.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K109.2 lm/W1572.6 lm/mF87.5 lm/W1259.8 lm/mF———
2300 K121.8 lm/W1754 lm/mE97.5 lm/W1404 lm/mF79 lm/W1137.6 lm/mG
2700 K131.2 lm/W1889.7 lm/mE105.7 lm/W1522.6 lm/mF85.7 lm/W1234.1 lm/mF
3000 K137.9 lm/W1985.4 lm/mD111.8 lm/W1609.7 lm/mE90.9 lm/W1308.3 lm/mF
3500 K139.9 lm/W2013.9 lm/mD114 lm/W1641.1 lm/mE93.7 lm/W1349.8 lm/mF
4000 K144 lm/W2073.9 lm/mD116.3 lm/W1675.4 lm/mE96.1 lm/W1384 lm/mF
5000 K143.8 lm/W2071.1 lm/mD116.3 lm/W1675.4 lm/mE96 lm/W1382.4 lm/mF
6500 K137.9 lm/W1985.4 lm/mD111.7 lm/W1608.3 lm/mE92.7 lm/W1334.9 lm/mF

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 19.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K105.6 lm/W2027.2 lm/mF84.6 lm/W1624 lm/mG———
2300 K117.8 lm/W2261.1 lm/mE94.3 lm/W1810 lm/mF76.4 lm/W1466.9 lm/mG
2700 K126.9 lm/W2436 lm/mE102.2 lm/W1962.8 lm/mF82.9 lm/W1590.9 lm/mG
3000 K133.3 lm/W2559.4 lm/mE108.1 lm/W2075.1 lm/mF87.8 lm/W1686.6 lm/mF
3500 K135.2 lm/W2596.2 lm/mD110.2 lm/W2115.6 lm/mE90.6 lm/W1740 lm/mF
4000 K139.2 lm/W2673.5 lm/mD112.5 lm/W2159.8 lm/mE92.9 lm/W1784.2 lm/mF
5000 K139.1 lm/W2669.8 lm/mD112.5 lm/W2159.8 lm/mE92.8 lm/W1781.8 lm/mF
6500 K133.3 lm/W2559.4 lm/mE108 lm/W2073.3 lm/mF89.6 lm/W1720.3 lm/mF

Grade DL (2nd Tier)

Grade DL (2nd Tier) — measured at 4.8 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K136.9 lm/W656.9 lm/mD109.7 lm/W526.5 lm/mF———
2300 K152.3 lm/W731.3 lm/mD122.2 lm/W586.6 lm/mE99 lm/W475.2 lm/mF
2700 K160.9 lm/W772.5 lm/mC132.2 lm/W634.5 lm/mE107.2 lm/W514.3 lm/mF
3000 K171.4 lm/W822.9 lm/mC139.2 lm/W668.1 lm/mD113.2 lm/W543.4 lm/mE
3500 K174 lm/W835.1 lm/mC141.6 lm/W679.8 lm/mD116.6 lm/W559.6 lm/mE
4000 K179.6 lm/W862.1 lm/mC145 lm/W696.1 lm/mD119.8 lm/W574.9 lm/mE
5000 K179.4 lm/W861.1 lm/mC144.9 lm/W695.6 lm/mD119.6 lm/W574.1 lm/mE
6500 K164.3 lm/W788.8 lm/mC139.1 lm/W667.6 lm/mD115.4 lm/W553.9 lm/mE

Grade DL (2nd Tier)

Grade DL (2nd Tier) — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K132.3 lm/W1270.3 lm/mE106.1 lm/W1018.2 lm/mF———
2300 K147.3 lm/W1414 lm/mD118.2 lm/W1134.4 lm/mE95.7 lm/W918.7 lm/mF
2700 K155.6 lm/W1493.8 lm/mD127.8 lm/W1226.9 lm/mE103.6 lm/W994.5 lm/mF
3000 K165.8 lm/W1591.3 lm/mC134.6 lm/W1291.9 lm/mE109.4 lm/W1050.7 lm/mF
3500 K168.2 lm/W1614.9 lm/mC136.9 lm/W1314.6 lm/mD112.7 lm/W1082.2 lm/mE
4000 K173.7 lm/W1667.1 lm/mC140.2 lm/W1346.1 lm/mD115.8 lm/W1111.7 lm/mE
5000 K173.5 lm/W1665.1 lm/mC140.1 lm/W1345.1 lm/mD115.6 lm/W1109.8 lm/mE
6500 K158.9 lm/W1525.3 lm/mD134.5 lm/W1290.9 lm/mE111.6 lm/W1071.4 lm/mE

Grade DL (2nd Tier)

Grade DL (2nd Tier) — measured at 14.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K127.9 lm/W1842.2 lm/mE102.5 lm/W1476.6 lm/mF———
2300 K142.4 lm/W2050.7 lm/mD114.2 lm/W1645.1 lm/mE92.5 lm/W1332 lm/mF
2700 K150.4 lm/W2166.4 lm/mD123.6 lm/W1779.4 lm/mE100.2 lm/W1442.4 lm/mF
3000 K160.3 lm/W2307.8 lm/mC130.1 lm/W1873.6 lm/mE105.8 lm/W1523.8 lm/mF
3500 K162.6 lm/W2342 lm/mC132.4 lm/W1906.5 lm/mE109 lm/W1569.5 lm/mF
4000 K167.9 lm/W2417.7 lm/mC135.6 lm/W1952.2 lm/mD112 lm/W1612.3 lm/mE
5000 K167.7 lm/W2414.9 lm/mC135.5 lm/W1950.7 lm/mD111.8 lm/W1609.9 lm/mE
6500 K153.6 lm/W2212.1 lm/mD130 lm/W1872.2 lm/mE107.9 lm/W1553.8 lm/mF

Grade DL (2nd Tier)

Grade DL (2nd Tier) — measured at 19.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K123.7 lm/W2374.8 lm/mE99.1 lm/W1903.6 lm/mF———
2300 K137.7 lm/W2643.6 lm/mD110.5 lm/W2120.8 lm/mE89.5 lm/W1718.4 lm/mF
2700 K145.5 lm/W2792.7 lm/mD119.5 lm/W2293.8 lm/mE96.8 lm/W1859.4 lm/mF
3000 K154.9 lm/W2975 lm/mD125.8 lm/W2415.3 lm/mE102.3 lm/W1964.3 lm/mF
3500 K157.2 lm/W3019.2 lm/mD128 lm/W2457.7 lm/mE105.4 lm/W2023.2 lm/mF
4000 K162.3 lm/W3116.8 lm/mC131.1 lm/W2516.6 lm/mE108.3 lm/W2078.4 lm/mF
5000 K162.1 lm/W3113.1 lm/mC131 lm/W2514.8 lm/mE108.1 lm/W2075.5 lm/mF
6500 K148.5 lm/W2851.7 lm/mD125.7 lm/W2413.5 lm/mE104.3 lm/W2002.6 lm/mF

High-Power LED Strip: Heat Dissipation & Aluminum Channel Guide

At up to 19.2W/m, 5274 is a high-power SMD LED strip. Above roughly 14.4W/m the tape can no longer shed its own heat through the FPC alone — an aluminum channel is part of the luminaire, not an accessory.

Why high-wattage strips need a heat sink

  • Aluminum conducts heat roughly 30× faster than the plastics, MDF or gypsum a strip is usually stuck to, so a bare high-power run traps heat under the tape.
  • LED lifetime (LM-80 / TM-21) is driven by solder-point temperature Tc. Keeping Tc inside the datasheet limit — DENO strips are rated Tc ≤ 75°C — is what preserves the rated L70 lifetime and colour stability.
  • Never run 14.4W/m or more coiled on the reel, inside a sealed plastic diffuser, or directly on wood, wallpaper or foam.

Sizing rule: FPC width vs channel inner width

  • Channel inner width ≥ FPC width + 2mm. This strip is 15mm wide, so it needs at least 17mm of inner width.
  • The 2mm clearance absorbs extrusion tolerance and lets the tape be seated or replaced without scraping the side walls or the wiring.
  • A frosted or opal PC cover then diffuses the higher lumen output into an even, dot-free line instead of visible hot spots.

Aluminum channels that fit this strip

Recommended LED Channels

Mount this LED strip in a DENO LED aluminum profile for heat dissipation, physical protection and diffused, dot-free output.

This strip is 15mm wide, so it needs a channel with at least 17mm inner width (15mm + 2mm clearance). Every profile below meets that.

Modelos relacionados nesta série

See every model in SMD LED Strip Series or narrow to Ic. Compare wattage, lumen output and run length in the ProCalc parameter library, or request OEM/ODM pricing on the custom manufacturing page.

Perguntas Frequentes

Quais são as principais especificações do modelo 5274?

5274: 2835, 140 LEDs/m, 24V, PCB de 15mm, FPCB com cobre de 3oz, corte a cada 14LEDs/100mm. Dados fotométricos completos, diagramas de ligação e relatórios de ensaio estão disponíveis na seção de downloads desta página.

Qual pode ser o comprimento de um único trecho desta Fita de LED para trechos ultralongos?

O comprimento máximo de um único trecho para este modelo é 10m. A alimentação pelas duas extremidades ou por um ponto intermediário reduz pela metade a distância efetiva por segmento, permitindo que uma Fita de LED para trechos ultralongos cubra o dobro desse comprimento em um único circuito quando conectada dessa forma.

A DENO pode personalizar esta Fita de LED para trechos ultralongos para um projeto?

Sim. A DENO fabrica a série de Fitas SMD Ultralongas como fornecedora OEM e ODM: comprimento do rolo, temperatura de cor, nível de IRC (CRI), largura da PCB, impermeabilização e identificação com marca própria podem ser especificados. Solicite um Orçamento para consultar o prazo de entrega e os preços para o projeto.

O que limita o comprimento de um trecho de Fita de LED?

A queda de tensão e a corrente no condutor, não o LED em si. Uma Fita de LED para trechos longos combina baixa potência em watts por metro, cobre de 2 oz ou mais espesso e uma tensão de barramento mais alta, como 24V, 36V ou 48V, para alcançar 20 m ou mais a partir de um único ponto de alimentação, mantendo a queda de tensão dentro de 3 por cento.

Uma Fita de LED de corrente constante realmente elimina a queda de tensão?

A tensão ainda cai ao longo do cobre, mas o IC de corrente constante de cada segmento mantém a corrente dos LEDs fixa até que a tensão local caia abaixo do seu limite mínimo de regulação. Assim, o brilho permanece uniforme de ponta a ponta, e a alimentação pode ser aplicada em uma extremidade, nas duas extremidades ou em qualquer ponto intermediário do trecho.

Engineering & selection guide

Bending limits, IP selection, voltage drop, cutting and the full buyer Q&A for this family are kept on the series page.