DENO LED Lighting

Fita de LED 2835 de Corrente Constante, Alto Fluxo Luminoso e Alta Eficácia Luminosa (#5932)

10mm · 24V · 112LEDs · 71.4corte

Model: 5932

5932 Fita de LED 2835 de Corrente Constante, Alto Fluxo Luminoso e Alta Eficácia Luminosa — 24V, corte a cada 71,4 mm, FPCB de 10 mm, LEDs 2835, 112 LEDs/m, IP20Desenho dimensional 5932 Fita de LED 2835 de Corrente Constante, Alto Fluxo Luminoso e Alta Eficácia Luminosa — FPCB de 10 mm, corte a cada 71,4 mm, 24V5932 Fita de LED 2835 de Corrente Constante, Alto Fluxo Luminoso e Alta Eficácia Luminosa — 24V, corte a cada 71,4 mm, FPCB de 10 mm, LEDs 2835, 112 LEDs/m, IP20 (vista 3)5932 Fita de LED 2835 de Corrente Constante, Alto Fluxo Luminoso e Alta Eficácia Luminosa — 24V, corte a cada 71,4 mm, FPCB de 10 mm, LEDs 2835, 112 LEDs/m, IP20 (vista 4)5932 Fita de LED 2835 de Corrente Constante, Alto Fluxo Luminoso e Alta Eficácia Luminosa — 24V, corte a cada 71,4 mm, FPCB de 10 mm, LEDs 2835, 112 LEDs/m, IP20 (vista 5)

Visão Geral

10mm | 24V | 112LEDs | 71.4cut | #5932 | Fita de LED 2835 de Corrente Constante, Alto Fluxo Luminoso e Alta Eficácia Luminosa faz parte da série DENO de Fitas SMD C.C. (Reguladas por IC), desenvolvida com base em Fita de LED com IC de corrente constante. Especificações principais: 2835, 112 LEDs/m, DC 24V, PCB de 10, FPCB de cobre de 3oz, corte a cada 8LEDs/71.4mm. Cada rolo é produzido na linha rolo a rolo da DENO com FPCB de cobre com pureza de 99.9% e é fornecido em conformidade com CE, UL e RoHS para projetos arquitetônicos, de varejo e de hotelaria. Configurações OEM e ODM de comprimento, temperatura de cor e impermeabilização estão disponíveis sob consulta.

Descrição

Projetada com 112 chips SMD 2835 por metro, esta Fita de LED de corrente constante de 24V proporciona desempenho uniforme para instalações de iluminação arquitetônica de alto padrão. A placa de circuito de 10mm de largura apresenta um projeto robusto com folha de cobre de 3oz para garantir estabilidade térmica ideal até uma temperatura máxima de 75°C. Estruturas de terminais dos LEDs em cobre puro durável, combinadas com encapsulamento com fio de ouro de 99.9% de pureza, protegem eficazmente os emissores contra esforços mecânicos durante a montagem. Pontos de corte precisos espaçados a cada 71.4mm, com passo de 8.9mm e capacidade de dimerização, permitem iluminação uniforme em um ângulo de abertura de 120 graus. Fornecida em trechos de comprimento máximo de 5M, com diâmetro de curvatura de 60mm, nossa oferta no atacado diretamente da fábrica para projetos atende a instalações comerciais personalizadas.

High Efficacy Led Strip Lights built for high light efficacy smd strips projects.

Especificações

LED QTY112 LEDs/m
PART NODL-F28A56V24-5932-*
SMD TYPE2835
UNIDADE DE CORTE8LEDs/71.4mm
DIMERIZÁVELYes
GRAU DE PROTEÇÃO IPIP20
LED PITCH8.9mm
LARGURA DA PCB10
ÂNGULO DE FACHO120°
COMPRIMENTO DO TRECHO5M
COPPER FOIL3oz
ON OFF TIMES10000(test times)
POWER RANGE5~20W
TIPO DE CIRCUITOC.C.
INPUT VOLTAGEDC 24V
MIN BEND DIAMETERΦ60mm
OPERATING TEMPERATURE-25~40°C;Tc:75°C(max)

Aplicações

  • Sancas, banho de luz em paredes e perímetros — Sancas, rebaixos, detalhes de banho de luz e perímetros de teto que exigem uma linha de luz contínua e uniforme.
  • Iluminação de exposição em showrooms e hotelaria — Prateleiras, vitrines, balcões de recepção e retroiluminação de letreiros em lojas, showrooms e espaços de hotelaria.
  • Iluminação sob armários de cozinha e closets — Iluminação de tarefa em cozinhas, closets e móveis, onde a fita fica oculta e apenas a luz é vista.

Acessórios recomendados e peças compatíveis

  • DL-1003 — 19.1x8mm Surface Mount LED Channel — Dotless Aluminum Profile for 240 LEDs/m Strip: Accepts LED strips up to 10mm wide.
  • DL-1103-1 — 16x13mm Surface Mount LED Channel — Aluminum Profile for 10mm LED Strip: Accepts LED strips up to 10mm wide.
  • DL-1510 HX-F — 15x9.9mm Recessed LED Channel with Flange — Flush Mount Aluminum Profile: Accepts LED strips up to 10mm wide.
  • DN-PSU-100 — 24V 100W Class-2 LED Driver · High Efficiency: Matches the 24V DC input of this strip; size the driver with at least 20% headroom over total load.
  • DN-PSU-150 — 24V 150W Class-2 LED Driver · Premium: Matches the 24V DC input of this strip; size the driver with at least 20% headroom over total load.
  • DN-PSU-60 — 24V 60W Class-2 LED Driver · Constant Voltage: Matches the 24V DC input of this strip; size the driver with at least 20% headroom over total load.
  • V1 — 5-36VDC 1-Channel * 8A RF+Push Dimming Controller | V1: Matched by input voltage range and colour channels.

Solicite um orçamento para #5932

A DENO LED é uma fabricante de fitas de LED com sede em Shenzhen e base de produção própria em Foshan. Envie-nos o comprimento do trecho, tensão, CCT/IRC e grau de proteção IP que você precisa e nossa equipe de engenharia responderá com uma ficha técnica, diagrama de fiação e preço — OEM/ODM e projetos totalmente personalizados incluídos.

Garantia
Conforme a ficha técnica do modelo
Prazo de entrega
Amostras personalizadas: 3–5 dias úteis · novo desenvolvimento: 1–3 semanas · produção em série: 1–2 semanas após aprovação da amostra
Conformidade
CE · RoHS · UL/ETL conforme o modelo e o mercado
Fio de ligação
Ouro puro 99,99%
Folha de cobre
FPCB de cobre puro 99,9%
Serviços
CCT, IRC, largura de PCB, unidade de corte e embalagem personalizadas — amostras e produção em massa de uma única fábrica.

Desempenho Fotométrico — Matriz de Eficácia CCT × IRC (CRI)

Peak measured luminous efficacy: 199.4 lm/W at 4000K, Ra 80, ErP energy class C (Grade DN (1st Tier) · 5W/m).

All values are measured at the stated power density and ambient 25 °C, reported as luminous efficacy in lumens per watt (lm/W), luminous flux per metre (lm/m) and the corresponding EU ErP (2019/2015) energy class.

Grade DL (2nd Tier) · 5W/m

Grade DL (2nd Tier) · 5W/m — measured at 5 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K146.6 lm/W732.9 lm/mD117.7 lm/W588.3 lm/mE———
2300 K163.3 lm/W816.4 lm/mC131.1 lm/W655.7 lm/mE106 lm/W529.8 lm/mF
2700 K172.7 lm/W863.6 lm/mC141.8 lm/W709.1 lm/mD115 lm/W574.8 lm/mE
3000 K183.8 lm/W919 lm/mC149.3 lm/W746.4 lm/mD121.4 lm/W607 lm/mE
3500 K186.5 lm/W932.5 lm/mB152 lm/W759.9 lm/mD125 lm/W625.1 lm/mE
4000 K192.4 lm/W962.1 lm/mB155.6 lm/W778 lm/mD128.4 lm/W642.2 lm/mE
5000 K192.2 lm/W961 lm/mB155.5 lm/W777.5 lm/mD128.8 lm/W643.8 lm/mE
6500 K176.2 lm/W881.2 lm/mC149.2 lm/W745.9 lm/mD123.8 lm/W618.9 lm/mE

Grade DL (2nd Tier) · 10W/m

Grade DL (2nd Tier) · 10W/m — measured at 10 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K141.5 lm/W1415.3 lm/mD113.6 lm/W1136 lm/mE———
2300 K157.6 lm/W1576.4 lm/mD126.6 lm/W1266.2 lm/mE102.3 lm/W1022.9 lm/mF
2700 K166.8 lm/W1667.5 lm/mC136.9 lm/W1369.2 lm/mD111 lm/W1110 lm/mE
3000 K177.5 lm/W1774.6 lm/mC144.1 lm/W1441.3 lm/mD117.2 lm/W1172.1 lm/mE
3500 K180.1 lm/W1800.6 lm/mC146.7 lm/W1467.3 lm/mD120.7 lm/W1207.1 lm/mE
4000 K185.8 lm/W1857.7 lm/mB150.2 lm/W1502.4 lm/mD124 lm/W1240.1 lm/mE
5000 K185.6 lm/W1855.7 lm/mB150.1 lm/W1501.4 lm/mD124.3 lm/W1243.1 lm/mE
6500 K170.2 lm/W1701.6 lm/mC144 lm/W1440.3 lm/mD119.5 lm/W1195.1 lm/mE

Grade DL (2nd Tier) · 13.5W/m

Grade DL (2nd Tier) · 13.5W/m — measured at 13.5 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K138.1 lm/W1864.2 lm/mD110.8 lm/W1496.4 lm/mE———
2300 K153.8 lm/W2076.5 lm/mD123.5 lm/W1667.8 lm/mE99.8 lm/W1347.4 lm/mF
2700 K162.7 lm/W2196.5 lm/mC133.6 lm/W1803.6 lm/mE108.3 lm/W1462.1 lm/mF
3000 K173.2 lm/W2337.6 lm/mC140.6 lm/W1898.5 lm/mD114.4 lm/W1543.9 lm/mE
3500 K175.7 lm/W2371.8 lm/mC143.2 lm/W1932.8 lm/mD117.8 lm/W1590 lm/mE
4000 K181.3 lm/W2447 lm/mC146.6 lm/W1978.9 lm/mD121 lm/W1633.5 lm/mE
5000 K181.1 lm/W2444.3 lm/mC146.5 lm/W1977.6 lm/mD121.3 lm/W1637.5 lm/mE
6500 K166 lm/W2241.3 lm/mC140.5 lm/W1897.2 lm/mD116.6 lm/W1574.2 lm/mE

Grade DL (2nd Tier) · 20W/m

Grade DL (2nd Tier) · 20W/m — measured at 20 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K131.9 lm/W2638.6 lm/mE105.9 lm/W2117.9 lm/mF———
2300 K147 lm/W2939 lm/mD118 lm/W2360.5 lm/mE95.4 lm/W1907.1 lm/mF
2700 K155.4 lm/W3108.8 lm/mD127.6 lm/W2552.7 lm/mE103.5 lm/W2069.4 lm/mF
3000 K165.4 lm/W3308.5 lm/mC134.4 lm/W2687.1 lm/mE109.3 lm/W2185.1 lm/mF
3500 K167.8 lm/W3357 lm/mC136.8 lm/W2735.6 lm/mD112.5 lm/W2250.4 lm/mE
4000 K173.2 lm/W3463.4 lm/mC140 lm/W2800.9 lm/mD115.6 lm/W2312 lm/mE
5000 K173 lm/W3459.6 lm/mC140 lm/W2799 lm/mD115.9 lm/W2317.6 lm/mE
6500 K158.6 lm/W3172.3 lm/mD134.3 lm/W2685.2 lm/mE111.4 lm/W2228 lm/mE

Grade DN (1st Tier) · 5W/m

Grade DN (1st Tier) · 5W/m — measured at 5 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K156.2 lm/W781.1 lm/mD131.8 lm/W658.8 lm/mE———
2300 K170.3 lm/W851.6 lm/mD147 lm/W735 lm/mD118.8 lm/W594 lm/mE
2700 K183.6 lm/W918 lm/mC159.1 lm/W795.7 lm/mD129 lm/W644.8 lm/mE
3000 K192.8 lm/W964.1 lm/mC167.9 lm/W839.7 lm/mD136.5 lm/W682.7 lm/mE
3500 K195.7 lm/W978.6 lm/mC171.6 lm/W857.9 lm/mD141.2 lm/W706 lm/mE
4000 K199.4 lm/W996.8 lm/mC172.5 lm/W862.5 lm/mD142.4 lm/W712.2 lm/mE
5000 K199.1 lm/W995.7 lm/mC173.6 lm/W868.2 lm/mC143.8 lm/W718.9 lm/mE
6500 K190.9 lm/W954.3 lm/mC166 lm/W829.9 lm/mD137.8 lm/W688.9 lm/mE

Grade DN (1st Tier) · 10W/m

Grade DN (1st Tier) · 10W/m — measured at 10 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K150.8 lm/W1508.4 lm/mD127.2 lm/W1272.2 lm/mE———
2300 K164.5 lm/W1644.5 lm/mD141.9 lm/W1419.3 lm/mE114.7 lm/W1147 lm/mF
2700 K177.3 lm/W1772.6 lm/mC153.6 lm/W1536.4 lm/mD124.5 lm/W1245.1 lm/mE
3000 K186.2 lm/W1861.7 lm/mC162.1 lm/W1621.5 lm/mD131.8 lm/W1318.2 lm/mE
3500 K189 lm/W1889.7 lm/mC165.7 lm/W1656.5 lm/mD136.3 lm/W1363.2 lm/mE
4000 K192.5 lm/W1924.8 lm/mC166.6 lm/W1665.5 lm/mD137.5 lm/W1375.3 lm/mE
5000 K192.3 lm/W1922.8 lm/mC167.7 lm/W1676.5 lm/mD138.8 lm/W1388.3 lm/mE
6500 K184.3 lm/W1842.7 lm/mC160.2 lm/W1602.5 lm/mD133 lm/W1330.2 lm/mE

Grade DN (1st Tier) · 13.5W/m

Grade DN (1st Tier) · 13.5W/m — measured at 13.5 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K147.2 lm/W1986.9 lm/mD124.1 lm/W1675.7 lm/mE———
2300 K160.5 lm/W2166.2 lm/mD138.5 lm/W1869.5 lm/mE111.9 lm/W1510.9 lm/mF
2700 K173 lm/W2334.9 lm/mC149.9 lm/W2023.8 lm/mD121.5 lm/W1640.1 lm/mE
3000 K181.6 lm/W2452.3 lm/mC158.2 lm/W2135.8 lm/mD128.6 lm/W1736.4 lm/mE
3500 K184.4 lm/W2489.2 lm/mC161.6 lm/W2182 lm/mD133 lm/W1795.7 lm/mE
4000 K187.8 lm/W2535.3 lm/mC162.5 lm/W2193.8 lm/mD134.2 lm/W1811.5 lm/mE
5000 K187.6 lm/W2532.7 lm/mC163.6 lm/W2208.3 lm/mD135.5 lm/W1828.6 lm/mE
6500 K179.8 lm/W2427.2 lm/mC156.4 lm/W2110.8 lm/mD129.8 lm/W1752.2 lm/mE

Grade DN (1st Tier) · 20W/m

Grade DN (1st Tier) · 20W/m — measured at 20 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K140.6 lm/W2812.1 lm/mE118.6 lm/W2371.7 lm/mF———
2300 K153.3 lm/W3065.9 lm/mD132.3 lm/W2646 lm/mE106.9 lm/W2138.5 lm/mF
2700 K165.2 lm/W3304.7 lm/mD143.2 lm/W2864.4 lm/mE116.1 lm/W2321.3 lm/mF
3000 K173.5 lm/W3470.8 lm/mC151.1 lm/W3023 lm/mD122.9 lm/W2457.6 lm/mE
3500 K176.2 lm/W3523.1 lm/mC154.4 lm/W3088.3 lm/mD127.1 lm/W2541.5 lm/mE
4000 K179.4 lm/W3588.4 lm/mC155.3 lm/W3105.1 lm/mD128.2 lm/W2563.9 lm/mE
5000 K179.2 lm/W3584.6 lm/mC156.3 lm/W3125.6 lm/mD129.4 lm/W2588.2 lm/mE
6500 K171.8 lm/W3435.4 lm/mD149.4 lm/W2987.5 lm/mD124 lm/W2480 lm/mE

Grade KE (3rd Tier) · 5W/m

Grade KE (3rd Tier) · 5W/m — measured at 5 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K125.5 lm/W627.7 lm/mE100.7 lm/W503.3 lm/mF———
2300 K140 lm/W699.8 lm/mD112.2 lm/W560.9 lm/mE90.6 lm/W453 lm/mF
2700 K150.8 lm/W754.2 lm/mD121.7 lm/W608.5 lm/mE98.7 lm/W493.5 lm/mF
3000 K158.4 lm/W792 lm/mD128.5 lm/W642.7 lm/mE104.5 lm/W522.5 lm/mF
3500 K160.8 lm/W804 lm/mC131 lm/W655.2 lm/mE107.9 lm/W539.6 lm/mF
4000 K165.5 lm/W827.3 lm/mC133.8 lm/W669.2 lm/mE110.5 lm/W552.6 lm/mE
5000 K165.2 lm/W826.2 lm/mC133.8 lm/W669.2 lm/mE110.8 lm/W554.1 lm/mE
6500 K158.4 lm/W792 lm/mD128.5 lm/W642.7 lm/mE106.7 lm/W533.4 lm/mF

Grade KE (3rd Tier) · 10W/m

Grade KE (3rd Tier) · 10W/m — measured at 10 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K121.2 lm/W1212.1 lm/mE97.2 lm/W971.9 lm/mF———
2300 K135.1 lm/W1351.2 lm/mD108.3 lm/W1083 lm/mF87.5 lm/W874.8 lm/mF
2700 K145.6 lm/W1456.3 lm/mD117.5 lm/W1175.1 lm/mE95.3 lm/W952.9 lm/mF
3000 K152.9 lm/W1529.4 lm/mD124.1 lm/W1241.1 lm/mE100.9 lm/W1008.9 lm/mF
3500 K155.2 lm/W1552.4 lm/mD126.5 lm/W1265.2 lm/mE104.2 lm/W1042 lm/mF
4000 K159.7 lm/W1597.5 lm/mD129.2 lm/W1292.2 lm/mE106.7 lm/W1067 lm/mF
5000 K159.5 lm/W1595.5 lm/mD129.2 lm/W1292.2 lm/mE107 lm/W1070 lm/mF
6500 K152.9 lm/W1529.4 lm/mD124.1 lm/W1241.1 lm/mE103 lm/W1029.9 lm/mF

Grade KE (3rd Tier) · 13.5W/m

Grade KE (3rd Tier) · 13.5W/m — measured at 13.5 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K118.3 lm/W1596.6 lm/mE94.8 lm/W1280.2 lm/mF———
2300 K131.8 lm/W1779.9 lm/mE105.7 lm/W1426.5 lm/mF85.4 lm/W1152.3 lm/mF
2700 K142.1 lm/W1918.3 lm/mD114.7 lm/W1547.8 lm/mE93 lm/W1255.1 lm/mF
3000 K149.2 lm/W2014.5 lm/mD121.1 lm/W1634.8 lm/mE98.4 lm/W1329 lm/mF
3500 K151.5 lm/W2044.9 lm/mD123.4 lm/W1666.5 lm/mE101.7 lm/W1372.5 lm/mF
4000 K155.9 lm/W2104.2 lm/mD126.1 lm/W1702.1 lm/mE104.1 lm/W1405.4 lm/mF
5000 K155.7 lm/W2101.6 lm/mD126.1 lm/W1702.1 lm/mE104.4 lm/W1409.4 lm/mF
6500 K149.2 lm/W2014.5 lm/mD121.1 lm/W1634.8 lm/mE100.5 lm/W1356.7 lm/mF

Grade KE (3rd Tier) · 20W/m

Grade KE (3rd Tier) · 20W/m — measured at 20 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K113 lm/W2259.8 lm/mE90.6 lm/W1811.9 lm/mF———
2300 K126 lm/W2519.1 lm/mE101 lm/W2019 lm/mF81.5 lm/W1630.9 lm/mG
2700 K135.8 lm/W2715.1 lm/mD109.5 lm/W2190.7 lm/mF88.8 lm/W1776.5 lm/mF
3000 K142.6 lm/W2851.3 lm/mD115.7 lm/W2313.9 lm/mE94 lm/W1881 lm/mF
3500 K144.7 lm/W2894.2 lm/mD117.9 lm/W2358.7 lm/mE97.1 lm/W1942.5 lm/mF
4000 K148.9 lm/W2978.2 lm/mD120.5 lm/W2409 lm/mE99.5 lm/W1989.2 lm/mF
5000 K148.7 lm/W2974.5 lm/mD120.5 lm/W2409 lm/mE99.7 lm/W1994.8 lm/mF
6500 K142.6 lm/W2851.3 lm/mD115.7 lm/W2313.9 lm/mE96 lm/W1920.1 lm/mF

High-Power LED Strip: Heat Dissipation & Aluminum Channel Guide

At up to 20W/m, 5932 is a high-power SMD LED strip. Above roughly 14.4W/m the tape can no longer shed its own heat through the FPC alone — an aluminum channel is part of the luminaire, not an accessory.

Why high-wattage strips need a heat sink

  • Aluminum conducts heat roughly 30× faster than the plastics, MDF or gypsum a strip is usually stuck to, so a bare high-power run traps heat under the tape.
  • LED lifetime (LM-80 / TM-21) is driven by solder-point temperature Tc. Keeping Tc inside the datasheet limit — DENO strips are rated Tc ≤ 75°C — is what preserves the rated L70 lifetime and colour stability.
  • Never run 14.4W/m or more coiled on the reel, inside a sealed plastic diffuser, or directly on wood, wallpaper or foam.

Sizing rule: FPC width vs channel inner width

  • Channel inner width ≥ FPC width + 2mm. This strip is 10mm wide, so it needs at least 12mm of inner width.
  • The 2mm clearance absorbs extrusion tolerance and lets the tape be seated or replaced without scraping the side walls or the wiring.
  • A frosted or opal PC cover then diffuses the higher lumen output into an even, dot-free line instead of visible hot spots.

Aluminum channels that fit this strip

Recommended LED Channels

Mount this LED strip in a DENO LED aluminum profile for heat dissipation, physical protection and diffused, dot-free output.

This strip is 10mm wide, so it needs a channel with at least 12mm inner width (10mm + 2mm clearance). Every profile below meets that.

Modelos relacionados nesta série

See every model in SMD LED Strip Series or narrow to Ic. Compare wattage, lumen output and run length in the ProCalc parameter library, or request OEM/ODM pricing on the custom manufacturing page.

Perguntas Frequentes

Quais dados estão registrados para o modelo 5932?

tensão: DC 24V; largura da PCB: 10; LEDs: 112 LEDs/m; encapsulamento: 2835; unidade de corte: 8LEDs/71.4mm; cobre: 3oz. Consulte a ficha técnica para a configuração do pedido.

Como confirmar a potência e a alimentação do modelo 5932?

Confirme a configuração na tabela de parâmetros do produto antes de dimensionar a fonte. Não extrapole comprimentos, corrente ou condições térmicas sem validação da instalação.

Como solicitar a configuração do modelo 5932?

Informe o modelo e as necessidades do projeto no pedido de orçamento. Temperatura de cor, proteção, amostra e prazo devem ser confirmados para a configuração solicitada.

Engineering & selection guide

Bending limits, IP selection, voltage drop, cutting and the full buyer Q&A for this family are kept on the series page.