DENO LED Lighting

Fita de LED 2835 para Trechos Longos (#5217)

12mm · 36V · 90LEDs · 100cut

Model: 5217

5217 fita de LED para longos trechos — 36V, corte a cada 100 mm, FPCB de 12 mm, LEDs 2835, 90 LEDs/m, 1800–6500KDesenho dimensional 5217 fita de LED para longos trechos — FPCB de 12 mm, corte a cada 100 mm, 36V5217 fita de LED para longos trechos — 36V, corte a cada 100 mm, FPCB de 12 mm, LEDs 2835, 90 LEDs/m, 1800–6500K (vista 3)5217 fita de LED para longos trechos — 36V, corte a cada 100 mm, FPCB de 12 mm, LEDs 2835, 90 LEDs/m, 1800–6500K (vista 4)5217 fita de LED para longos trechos — 36V, corte a cada 100 mm, FPCB de 12 mm, LEDs 2835, 90 LEDs/m, 1800–6500K (vista 5)

Visão Geral

12mm | 36V | 90LEDs | 100cut | #5217 | Fita de LED 2835 Ultralonga faz parte da série de Fitas SMD de 36V da DENO, desenvolvida com base em Fitas de LED de 36V. Especificações principais: 2835, 90 LEDs/m, 36V, PCB de 12 mm, FPCB de cobre de 3oz, corte a cada 9LEDs/100mm. Cada rolo é produzido na linha rolo a rolo da DENO com FPCB de cobre com pureza de 99.9% e é fornecido em conformidade com CE, UL e RoHS para projetos de arquitetura, varejo e hotelaria. Configurações OEM e ODM de comprimento, temperatura de cor e impermeabilização estão disponíveis mediante solicitação.

Descrição

Operando com um circuito de corrente constante de 36V, esta Fita de LED 2835 permite trechos contínuos únicos de até 25 metros com menos pontos de alimentação. Projetada em uma robusta PCB de cobre de 3oz e 12mm de largura, a fita apresenta 90 LEDs por metro com intervalos precisos de corte a cada 100mm. O design dimerizável oferece um amplo ângulo de abertura de 120 graus em uma faixa de potência de 1.8W a 22W para projetos de iluminação arquitetônica linear. Com diâmetro mínimo de curvatura de 60mm e faixa de temperatura de operação de -25°C a 40°C, a fita garante flexibilidade mecânica confiável. Disponível para fornecimento de projetos no atacado diretamente da fábrica, com comprimentos personalizados OEM, temperaturas de cor e opções de proteção contra ingresso sob solicitação.

We use 99.99% gold wire, large-size chips, and thickened FPCB, backed by a 5-year warranty.

Especificações

CCT (K)1800–6500K
IRC (CRI)Ra≥90
LED QTY90 LEDs/m
PART NODL-F28A45V36-5217-*
SMD TYPE2835
UNIDADE DE CORTE9LEDs/100mm
DIMERIZÁVELYes
GRAU DE PROTEÇÃO IPIP20
LED PITCH11.11mm
LARGURA DA PCB12 mm
ÂNGULO DE FACHO120°
COMPRIMENTO DO TRECHO25M
COPPER FOIL3oz
ON OFF TIMES10000(test times)
POWER RANGE3.6~22W
TIPO DE CIRCUITOC.C.
INPUT VOLTAGE36V
FLUXO LUMINOSO90–1171 lm/m
MIN BEND DIAMETERΦ60mm
OPERATING TEMPERATURE-25~40°C;Tc:75°C(max)

Aplicações

  • Sancas, banho de luz em paredes e perímetros — Sancas, rebaixos, detalhes de banho de luz e perímetros de teto que exigem uma linha de luz contínua e uniforme.
  • Iluminação de exposição em showrooms e hotelaria — Prateleiras, vitrines, balcões de recepção e retroiluminação de letreiros em lojas, showrooms e espaços de hotelaria.
  • Iluminação sob armários de cozinha e closets — Iluminação de tarefa em cozinhas, closets e móveis, onde a fita fica oculta e apenas a luz é vista.
  • Trechos longos em corredores e armazéns — Trechos longos com alimentação única em 36 V cobrem corredores, ruas de armazéns e linhas de fachada com menos pontos de alimentação e menos fontes.

Acessórios recomendados e peças compatíveis

  • DL-1201 — 25x14.5mm Wide Surface Mount LED Channel — Aluminum Profile for 12mm Strip: Accepts LED strips up to 12mm wide.
  • DL-1202 — 17.3x14.5mm Surface Mount LED Channel — Deep Aluminum Profile for 12mm Strip: Accepts LED strips up to 12mm wide.
  • DL-1204 — 25x7mm Wide Slim Surface Mount LED Channel — Dotless Aluminum Profile for 240 LEDs/m: Accepts LED strips up to 12mm wide.
  • V1 — 5-36VDC 1-Channel * 8A RF+Push Dimming Controller | V1: Matched by input voltage range and colour channels.

Solicite um orçamento para #5217

A DENO LED é uma fabricante de fitas de LED com sede em Shenzhen e base de produção própria em Foshan. Envie-nos o comprimento do trecho, tensão, CCT/IRC e grau de proteção IP que você precisa e nossa equipe de engenharia responderá com uma ficha técnica, diagrama de fiação e preço — OEM/ODM e projetos totalmente personalizados incluídos.

Garantia
Conforme a ficha técnica do modelo
Prazo de entrega
Amostras personalizadas: 3–5 dias úteis · novo desenvolvimento: 1–3 semanas · produção em série: 1–2 semanas após aprovação da amostra
Conformidade
CE · RoHS · UL/ETL conforme o modelo e o mercado
Fio de ligação
Ouro puro 99,99%
Folha de cobre
FPCB de cobre puro 99,9%
Serviços
CCT, IRC, largura de PCB, unidade de corte e embalagem personalizadas — amostras e produção em massa de uma única fábrica.

Desempenho Fotométrico — Matriz de Eficácia CCT × IRC (CRI)

Peak measured luminous efficacy: 143.5 lm/W at 4000K, Ra 80, ErP energy class E (Grade DN (1st Tier) · 5.4W/m).

All values are measured at the stated power density and ambient 25 °C, reported as luminous efficacy in lumens per watt (lm/W), luminous flux per metre (lm/m) and the corresponding EU ErP (2019/2015) energy class.

Grade DL (2nd Tier) · 5.4W/m

Grade DL (2nd Tier) · 5.4W/m — measured at 5.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K100.9 lm/W544.7 lm/mF80.6 lm/W435.3 lm/mG———
2300 K112.2 lm/W605.9 lm/mE89.8 lm/W485.1 lm/mF72.5 lm/W391.6 lm/mG
2700 K118 lm/W637.1 lm/mE97.1 lm/W524.5 lm/mF78.7 lm/W424.9 lm/mG
3000 K126.3 lm/W682 lm/mE102.3 lm/W552.3 lm/mF83.1 lm/W449 lm/mG
3500 K128.2 lm/W692.3 lm/mE104 lm/W561.6 lm/mF85.7 lm/W462.7 lm/mF
4000 K132.4 lm/W714.8 lm/mE106.5 lm/W575.3 lm/mF88 lm/W475.2 lm/mF
5000 K132.2 lm/W713.7 lm/mE106.5 lm/W575.3 lm/mF88.2 lm/W476.3 lm/mF
6500 K120.8 lm/W652.4 lm/mE102.2 lm/W551.8 lm/mF84.8 lm/W457.7 lm/mG

Grade DL (2nd Tier) · 7.2W/m

Grade DL (2nd Tier) · 7.2W/m — measured at 7.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K99.6 lm/W717 lm/mF79.6 lm/W573 lm/mG———
2300 K110.8 lm/W798 lm/mE88.7 lm/W638.4 lm/mF71.6 lm/W515.8 lm/mG
2700 K116.5 lm/W838.8 lm/mE95.9 lm/W690.8 lm/mF77.7 lm/W559.8 lm/mG
3000 K124.7 lm/W898.1 lm/mE101 lm/W726.9 lm/mF82.1 lm/W591.2 lm/mG
3500 K126.6 lm/W912 lm/mE102.7 lm/W739.9 lm/mF84.6 lm/W609 lm/mG
4000 K130.7 lm/W941 lm/mE105.2 lm/W757.7 lm/mF86.9 lm/W625.5 lm/mF
5000 K130.5 lm/W940.1 lm/mE105.2 lm/W757.3 lm/mF87.1 lm/W627 lm/mF
6500 K119.3 lm/W859.3 lm/mE100.9 lm/W726.5 lm/mF83.7 lm/W603 lm/mG

Grade DL (2nd Tier) · 11W/m

Grade DL (2nd Tier) · 11W/m — measured at 11 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K97 lm/W1066.7 lm/mF77.5 lm/W852.5 lm/mG———
2300 K107.9 lm/W1186.7 lm/mF86.4 lm/W950 lm/mF69.7 lm/W766.9 lm/mG
2700 K113.4 lm/W1247.8 lm/mE93.4 lm/W1027.1 lm/mF75.7 lm/W832.2 lm/mG
3000 K121.4 lm/W1335.6 lm/mE98.3 lm/W1081.7 lm/mF79.9 lm/W879.3 lm/mG
3500 K123.3 lm/W1355.9 lm/mE100 lm/W1100 lm/mF82.4 lm/W906.1 lm/mG
4000 K127.3 lm/W1399.8 lm/mE102.4 lm/W1126.7 lm/mF84.6 lm/W930.7 lm/mG
5000 K127.1 lm/W1397.7 lm/mE102.4 lm/W1126.7 lm/mF84.8 lm/W932.9 lm/mG
6500 K116.2 lm/W1277.7 lm/mE98.2 lm/W1080.7 lm/mF81.5 lm/W896.5 lm/mG

Grade DL (2nd Tier) · 14.4W/m

Grade DL (2nd Tier) · 14.4W/m — measured at 14.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K94.7 lm/W1363.5 lm/mF75.7 lm/W1089.7 lm/mG———
2300 K105.3 lm/W1516.8 lm/mF84.3 lm/W1214.3 lm/mG68.1 lm/W980.2 lm/mG
2700 K110.8 lm/W1594.9 lm/mE91.2 lm/W1312.9 lm/mF73.9 lm/W1063.7 lm/mG
3000 K118.6 lm/W1707.1 lm/mE96 lm/W1382.7 lm/mF78.1 lm/W1123.9 lm/mG
3500 K120.4 lm/W1733.1 lm/mE97.6 lm/W1406 lm/mF80.4 lm/W1158.2 lm/mG
4000 K124.3 lm/W1789.3 lm/mE100 lm/W1440.2 lm/mF82.6 lm/W1189.7 lm/mG
5000 K124.1 lm/W1786.5 lm/mE100 lm/W1440.2 lm/mF82.8 lm/W1192.4 lm/mG
6500 K113.4 lm/W1633.2 lm/mE95.9 lm/W1381.3 lm/mF79.6 lm/W1145.8 lm/mG

Grade DN (1st Tier) · 5.4W/m

Grade DN (1st Tier) · 5.4W/m — measured at 5.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K112.4 lm/W607 lm/mF94.5 lm/W510.2 lm/mF———
2300 K122.5 lm/W661.7 lm/mE105.4 lm/W569.3 lm/mF85.2 lm/W459.9 lm/mG
2700 K132.2 lm/W713.7 lm/mE114.1 lm/W616.3 lm/mF92.5 lm/W499.3 lm/mF
3000 K138.7 lm/W749.2 lm/mE120.5 lm/W650.8 lm/mE98 lm/W529.4 lm/mF
3500 K140.9 lm/W760.7 lm/mE123.1 lm/W665 lm/mE101.4 lm/W547.4 lm/mF
4000 K143.5 lm/W774.9 lm/mE123.9 lm/W668.8 lm/mE102.2 lm/W551.8 lm/mF
5000 K143.3 lm/W773.8 lm/mE124.7 lm/W673.2 lm/mE103.2 lm/W557.3 lm/mF
6500 K137.3 lm/W741.6 lm/mE119.1 lm/W643.1 lm/mE98.8 lm/W533.8 lm/mF

Grade DN (1st Tier) · 7.2W/m

Grade DN (1st Tier) · 7.2W/m — measured at 7.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K111 lm/W799.4 lm/mF93.3 lm/W672.1 lm/mF———
2300 K121 lm/W871.6 lm/mE104.1 lm/W749.9 lm/mF84.1 lm/W605.9 lm/mG
2700 K130.5 lm/W939.5 lm/mE112.7 lm/W811.5 lm/mF91.3 lm/W657.7 lm/mG
3000 K137 lm/W986.7 lm/mE119 lm/W856.9 lm/mE96.8 lm/W696.9 lm/mF
3500 K139.1 lm/W1001.3 lm/mE121.6 lm/W875.6 lm/mE100.1 lm/W720.6 lm/mF
4000 K141.7 lm/W1020.2 lm/mE122.3 lm/W880.4 lm/mE100.9 lm/W726.8 lm/mF
5000 K141.5 lm/W1018.7 lm/mE123.1 lm/W886.2 lm/mE101.9 lm/W733.8 lm/mF
6500 K135.6 lm/W976.6 lm/mE117.6 lm/W846.8 lm/mF97.6 lm/W702.9 lm/mF

Grade DN (1st Tier) · 11W/m

Grade DN (1st Tier) · 11W/m — measured at 11 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K108.1 lm/W1188.8 lm/mF90.8 lm/W999.3 lm/mG———
2300 K117.8 lm/W1296 lm/mF101.4 lm/W1114.9 lm/mF81.9 lm/W900.7 lm/mG
2700 K127.1 lm/W1397.7 lm/mE109.7 lm/W1207.1 lm/mF88.9 lm/W977.9 lm/mG
3000 K133.4 lm/W1467.3 lm/mE115.9 lm/W1274.5 lm/mF94.3 lm/W1036.8 lm/mF
3500 K135.4 lm/W1489.8 lm/mE118.4 lm/W1302.4 lm/mF97.5 lm/W1072.1 lm/mF
4000 K138 lm/W1517.7 lm/mE119.1 lm/W1309.9 lm/mE98.2 lm/W1080.7 lm/mF
5000 K137.8 lm/W1515.5 lm/mE119.9 lm/W1318.4 lm/mE99.2 lm/W1091.4 lm/mF
6500 K132 lm/W1452.3 lm/mE114.5 lm/W1259.5 lm/mF95 lm/W1045.3 lm/mF

Grade DN (1st Tier) · 14.4W/m

Grade DN (1st Tier) · 14.4W/m — measured at 14.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K105.5 lm/W1519.6 lm/mF88.7 lm/W1277.3 lm/mG———
2300 K115 lm/W1656.5 lm/mF99 lm/W1425.1 lm/mF80 lm/W1151.3 lm/mG
2700 K124.1 lm/W1786.5 lm/mE107.1 lm/W1542.9 lm/mF86.8 lm/W1249.9 lm/mG
3000 K130.2 lm/W1875.5 lm/mE113.1 lm/W1629.1 lm/mF92 lm/W1325.2 lm/mF
3500 K132.2 lm/W1904.3 lm/mE115.6 lm/W1664.7 lm/mF95.2 lm/W1370.4 lm/mF
4000 K134.7 lm/W1939.9 lm/mE116.3 lm/W1674.3 lm/mF95.9 lm/W1381.3 lm/mF
5000 K134.5 lm/W1937.1 lm/mE117 lm/W1685.2 lm/mF96.9 lm/W1395 lm/mF
6500 K128.9 lm/W1856.3 lm/mE111.8 lm/W1609.9 lm/mF92.8 lm/W1336.1 lm/mF

Grade KE (3rd Tier) · 5.4W/m

Grade KE (3rd Tier) · 5.4W/m — measured at 5.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K80.5 lm/W434.8 lm/mG64.2 lm/W346.7 lm/mG———
2300 K89.7 lm/W484.5 lm/mF71.5 lm/W386.1 lm/mG57.8 lm/W312.3 lm/mG
2700 K96.7 lm/W522.3 lm/mF77.6 lm/W418.9 lm/mG62.9 lm/W339.6 lm/mG
3000 K101.6 lm/W548.5 lm/mF82 lm/W443 lm/mG66.7 lm/W360.4 lm/mG
3500 K103.1 lm/W556.7 lm/mF83.7 lm/W451.7 lm/mG68.9 lm/W371.9 lm/mG
4000 K106.1 lm/W573.1 lm/mF85.5 lm/W461.6 lm/mF70.5 lm/W380.6 lm/mG
5000 K106 lm/W572.6 lm/mF85.4 lm/W461 lm/mF70.7 lm/W381.7 lm/mG
6500 K101.6 lm/W548.5 lm/mF82 lm/W443 lm/mG68.1 lm/W367.5 lm/mG

Grade KE (3rd Tier) · 7.2W/m

Grade KE (3rd Tier) · 7.2W/m — measured at 7.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K79.5 lm/W572.6 lm/mG63.4 lm/W456.2 lm/mG———
2300 K88.6 lm/W638.3 lm/mF70.6 lm/W508.5 lm/mG57.1 lm/W410.9 lm/mG
2700 K95.5 lm/W687.9 lm/mF76.6 lm/W551.6 lm/mG62.1 lm/W447.1 lm/mG
3000 K100.3 lm/W722.5 lm/mF81 lm/W583.3 lm/mG65.9 lm/W474.4 lm/mG
3500 K101.8 lm/W733.3 lm/mF82.6 lm/W594.8 lm/mG68 lm/W489.6 lm/mG
4000 K104.8 lm/W754.7 lm/mF84.4 lm/W607.6 lm/mG69.6 lm/W501.5 lm/mG
5000 K104.7 lm/W753.6 lm/mF84.3 lm/W607.4 lm/mG69.8 lm/W502.9 lm/mG
6500 K100.3 lm/W722.5 lm/mF81 lm/W583.1 lm/mG67.2 lm/W483.9 lm/mG

Grade KE (3rd Tier) · 11W/m

Grade KE (3rd Tier) · 11W/m — measured at 11 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K77.4 lm/W851.5 lm/mG61.7 lm/W679 lm/mG———
2300 K86.3 lm/W948.9 lm/mF68.7 lm/W756.1 lm/mG55.6 lm/W611.6 lm/mG
2700 K93 lm/W1022.8 lm/mF74.6 lm/W820.4 lm/mG60.5 lm/W665.1 lm/mG
3000 K97.7 lm/W1074.2 lm/mF78.9 lm/W867.5 lm/mG64.2 lm/W705.8 lm/mG
3500 K99.1 lm/W1090.3 lm/mF80.4 lm/W884.7 lm/mG66.2 lm/W728.3 lm/mG
4000 K102 lm/W1122.4 lm/mF82.2 lm/W904 lm/mG67.8 lm/W745.4 lm/mG
5000 K101.9 lm/W1121.4 lm/mF82.1 lm/W902.9 lm/mG68 lm/W747.6 lm/mG
6500 K97.7 lm/W1074.2 lm/mF78.9 lm/W867.5 lm/mG65.4 lm/W719.7 lm/mG

Grade KE (3rd Tier) · 14.4W/m

Grade KE (3rd Tier) · 14.4W/m — measured at 14.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K75.6 lm/W1088.3 lm/mG60.3 lm/W867.9 lm/mG———
2300 K84.2 lm/W1212.9 lm/mG67.1 lm/W966.5 lm/mG54.3 lm/W781.7 lm/mG
2700 K90.8 lm/W1307.4 lm/mF72.8 lm/W1048.6 lm/mG59 lm/W850.1 lm/mG
3000 K95.4 lm/W1373.1 lm/mF77 lm/W1108.9 lm/mG62.7 lm/W902.2 lm/mG
3500 K96.8 lm/W1393.6 lm/mF78.5 lm/W1130.8 lm/mG64.6 lm/W930.9 lm/mG
4000 K99.6 lm/W1434.7 lm/mF80.2 lm/W1155.4 lm/mG66.2 lm/W952.8 lm/mG
5000 K99.5 lm/W1433.3 lm/mF80.1 lm/W1154.1 lm/mG66.4 lm/W955.6 lm/mG
6500 K95.4 lm/W1373.1 lm/mF77 lm/W1108.9 lm/mG63.9 lm/W920 lm/mG

High-Power LED Strip: Heat Dissipation & Aluminum Channel Guide

At up to 14.4W/m, 5217 is a high-power SMD LED strip. Above roughly 14.4W/m the tape can no longer shed its own heat through the FPC alone — an aluminum channel is part of the luminaire, not an accessory.

Why high-wattage strips need a heat sink

  • Aluminum conducts heat roughly 30× faster than the plastics, MDF or gypsum a strip is usually stuck to, so a bare high-power run traps heat under the tape.
  • LED lifetime (LM-80 / TM-21) is driven by solder-point temperature Tc. Keeping Tc inside the datasheet limit — DENO strips are rated Tc ≤ 75°C — is what preserves the rated L70 lifetime and colour stability.
  • Never run 14.4W/m or more coiled on the reel, inside a sealed plastic diffuser, or directly on wood, wallpaper or foam.

Sizing rule: FPC width vs channel inner width

  • Channel inner width ≥ FPC width + 2mm. This strip is 12mm wide, so it needs at least 14mm of inner width.
  • The 2mm clearance absorbs extrusion tolerance and lets the tape be seated or replaced without scraping the side walls or the wiring.
  • A frosted or opal PC cover then diffuses the higher lumen output into an even, dot-free line instead of visible hot spots.

Aluminum channels that fit this strip

Recommended LED Channels

Mount this LED strip in a DENO LED aluminum profile for heat dissipation, physical protection and diffused, dot-free output.

This strip is 12mm wide, so it needs a channel with at least 14mm inner width (12mm + 2mm clearance). Every profile below meets that.

Modelos relacionados nesta série

See every model in SMD LED Strip Series or narrow to Ic. Compare wattage, lumen output and run length in the ProCalc parameter library, or request OEM/ODM pricing on the custom manufacturing page.

Perguntas Frequentes

Quais são as principais especificações do 5217?

5217: 2835, 90 LEDs/m, 36V, PCB de 12 mm, FPCB com cobre de 3oz, corte a cada 9LEDs/100mm. Dados fotométricos completos, diagramas de ligação e relatórios de ensaio estão disponíveis na seção de downloads desta página.

Qual pode ser o comprimento de um único trecho desta Fita de LED de 36V?

O comprimento máximo de um único trecho deste modelo é 25M. A alimentação pelas duas extremidades ou por um ponto central reduz pela metade a distância efetiva por segmento, permitindo que uma Fita de LED de 36V cubra o dobro desse comprimento em um único circuito quando conectada dessa forma.

A DENO pode personalizar esta Fita de LED de 36V para um projeto?

Sim. A DENO fabrica a série de Fitas SMD de 36V como fornecedora OEM e ODM: comprimento do rolo, temperatura de cor, classe de IRC (CRI), largura do PCB, impermeabilização e identificação com marca própria podem ser especificados. Solicite um Orçamento para consultar o prazo de entrega e os preços do projeto.

O que limita o comprimento de um trecho de Fita de LED?

A queda de tensão e a corrente nos condutores, não o LED em si. Uma Fita de LED para trechos longos combina baixa potência por metro, cobre de 2 oz ou mais espesso e uma tensão de barramento mais alta, como 24V, 36V ou 48V, para alcançar 20 m ou mais a partir de um único ponto de alimentação, mantendo a queda dentro de 3 por cento.

Quando usar uma Fita de LED de 36V em vez de 24V?

Escolha 36V quando um único trecho exceder o comprimento que uma Fita de LED de 24V pode alimentar dentro de uma queda de tensão de 3 por cento. Com a mesma potência por metro, uma tensão de barramento mais alta significa menor corrente e aproximadamente metade da queda de 24V na mesma distância, permitindo alimentar trechos em corredores, fachadas e sancas por uma única extremidade, com menos pontos de injeção de alimentação.

Engineering & selection guide

Bending limits, IP selection, voltage drop, cutting and the full buyer Q&A for this family are kept on the series page.