DENO LED Lighting

Fita de LED 2835 PU de Alta Eficácia Luminosa (#7923-PU)

10mm · 24V · 128LEDs · 62.5mm/corte

Model: 7923-PU

7923-PU Fita de LED 2835 PU de Alta Eficácia Luminosa — 24V, corte a cada 62,5 mm, FPCB de 10 mm, LEDs 2835, 128 LEDs/m, 1800–6500KDesenho dimensional 7923-PU Fita de LED 2835 PU de Alta Eficácia Luminosa — FPCB de 10 mm, corte a cada 62,5 mm, 24V7923-PU Fita de LED 2835 PU de Alta Eficácia Luminosa — 24V, corte a cada 62,5 mm, FPCB de 10 mm, LEDs 2835, 128 LEDs/m, 1800–6500K (vista 3)

Visão Geral

Fita de LED 2835 PU de alta eficácia luminosa | 10mm | 24V | 128LEDs | 62.5mm/corte | #7923-PU faz parte da série DENO de Fitas SMD para uso marítimo, desenvolvida com base em Fita de LED para uso marítimo. Especificações principais: 2835, 128, 24V, PCB de 10mm, FPCB de cobre de 3 oz, corte a cada 8LEDs/62.5mm, IP68PU, IRC (CRI) Ra≥80 , Ra≥90 , Ra≥95 , FS. Cada rolo é produzido na linha rolo a rolo da DENO com FPCB de cobre de pureza 99.9% e é fornecido em conformidade com CE, UL e RoHS para projetos de arquitetura, varejo e hotelaria. Configurações OEM e ODM de comprimento, temperatura de cor e impermeabilização estão disponíveis sob consulta.

Descrição

Esta Fita de LED 2835 PU utiliza emissores de alta eficácia, fornecendo até 1929 lúmens por metro para iluminação linear profissional. O encapsulamento avançado em poliuretano proporciona proteção IP68 contra ingresso de água e resistência aos raios UV para proteger de forma confiável os componentes internos contra as intempéries. Projetada com uma placa de circuito impresso de cobre durável de 3 oz e circuitos de corrente constante de 24V, permite cortes precisos a cada 62.5mm. A construção totalmente selada é ideal para iluminação arquitetônica de fachadas externas, iluminação de caminhos externos e projetos paisagísticos decorativos. A DENO oferece fornecimento no atacado para projetos diretamente da fábrica, com comprimentos personalizados OEM e múltiplas opções de reprodução de cor para atender às especificações de engenharia.

We use 99.99% gold wire, large-size chips, and thickened FPCB, backed by a 5-year warranty.

Especificações

CCT (K)1800-6500
IRC (CRI)Ra≥80 , Ra≥90 , Ra≥95 , FS
SDCM< 3 SDCM (Single Bin)
LED QTY128
PART NODL-F28D64V24-7923-PU*
SMD TYPE2835
UNIDADE DE CORTE8LEDs/62.5mm
DIMERIZÁVELYes
GRAU DE PROTEÇÃO IPIP68PU
LED PITCH7.8mm
VIDA ÚTIL ESTIMADA50000h
LARGURA DA PCB10mm
GARANTIA5 Years
ÂNGULO DE FACHO120°
COMPRIMENTO DO TRECHO5m
COPPER FOIL3 oz
ON OFF TIMES10000 (test times)
POWER RANGE15W/m
TIPO DE CIRCUITOC.C.
INPUT VOLTAGE24V
FLUXO LUMINOSO1929 lm/m
MIN BEND DIAMETERΦ60mm
OPERATING TEMPERATURE-25~40°C;Tc: 75°C (max)

Aplicações

  • Sancas, banho de luz em paredes e perímetros — Sancas, rebaixos, detalhes de banho de luz e perímetros de teto que exigem uma linha de luz contínua e uniforme.
  • Iluminação de exposição em showrooms e hotelaria — Prateleiras, vitrines, balcões de recepção e retroiluminação de letreiros em lojas, showrooms e espaços de hotelaria.
  • Iluminação sob armários de cozinha e closets — Iluminação de tarefa em cozinhas, closets e móveis, onde a fita fica oculta e apenas a luz é vista.
  • Fachadas, paisagismo e banheiros (IP68PU) — A vedação IP68PU é adequada para fachadas, paisagismo, banheiros e outros locais expostos a chuva, respingos ou lavagem.

Acessórios recomendados e peças compatíveis

  • DL-1003 — 19.1x8mm Surface Mount LED Channel — Dotless Aluminum Profile for 240 LEDs/m Strip: Accepts LED strips up to 10mm wide.
  • DL-1103-1 — 16x13mm Surface Mount LED Channel — Aluminum Profile for 10mm LED Strip: Accepts LED strips up to 10mm wide.
  • DL-1510 HX-F — 15x9.9mm Recessed LED Channel with Flange — Flush Mount Aluminum Profile: Accepts LED strips up to 10mm wide.
  • DN-PSU-100 — 24V 100W Class-2 LED Driver · High Efficiency: Matches the 24V DC input of this strip; size the driver with at least 20% headroom over total load.
  • DN-PSU-150 — 24V 150W Class-2 LED Driver · Premium: Matches the 24V DC input of this strip; size the driver with at least 20% headroom over total load.
  • DN-PSU-60 — 24V 60W Class-2 LED Driver · Constant Voltage: Matches the 24V DC input of this strip; size the driver with at least 20% headroom over total load.
  • V1 — 5-36VDC 1-Channel * 8A RF+Push Dimming Controller | V1: Matched by input voltage range and colour channels.

Solicite um orçamento para #7923-PU

A DENO LED é uma fabricante de fitas de LED com sede em Shenzhen e base de produção própria em Foshan. Envie-nos o comprimento do trecho, tensão, CCT/IRC e grau de proteção IP que você precisa e nossa equipe de engenharia responderá com uma ficha técnica, diagrama de fiação e preço — OEM/ODM e projetos totalmente personalizados incluídos.

Garantia
Conforme a ficha técnica do modelo
Prazo de entrega
Amostras personalizadas: 3–5 dias úteis · novo desenvolvimento: 1–3 semanas · produção em série: 1–2 semanas após aprovação da amostra
Conformidade
CE · RoHS · UL/ETL conforme o modelo e o mercado
Fio de ligação
Ouro puro 99,99%
Folha de cobre
FPCB de cobre puro 99,9%
Serviços
CCT, IRC, largura de PCB, unidade de corte e embalagem personalizadas — amostras e produção em massa de uma única fábrica.

Desempenho Fotométrico — Matriz de Eficácia CCT × IRC (CRI)

Peak measured luminous efficacy: 181.3 lm/W at 4000K, Ra 80, ErP energy class C (Grade DN (1st Tier) · 9.6W/m).

All values are measured at the stated power density and ambient 25 °C, reported as luminous efficacy in lumens per watt (lm/W), luminous flux per metre (lm/m) and the corresponding EU ErP (2019/2015) energy class.

Grade DL (2nd Tier) · 9.6W/m

Grade DL (2nd Tier) · 9.6W/m — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K131.6 lm/W1263.5 lm/mE105.5 lm/W1012.6 lm/mF———
2300 K146.5 lm/W1406.5 lm/mD117.6 lm/W1128.6 lm/mE95 lm/W911.7 lm/mF
2700 K154.7 lm/W1485.5 lm/mD127.1 lm/W1220.6 lm/mE103.1 lm/W989.6 lm/mF
3000 K164.9 lm/W1583.4 lm/mC133.8 lm/W1284.5 lm/mE108.8 lm/W1044.6 lm/mF
3500 K167.4 lm/W1607.4 lm/mC136.2 lm/W1307.5 lm/mD112.1 lm/W1076.6 lm/mE
4000 K172.8 lm/W1658.4 lm/mC139.5 lm/W1339.5 lm/mD115.2 lm/W1105.6 lm/mE
5000 K172.5 lm/W1656.4 lm/mC139.4 lm/W1338.5 lm/mD115.5 lm/W1108.6 lm/mE
6500 K158.1 lm/W1517.5 lm/mD133.8 lm/W1284.5 lm/mE111 lm/W1065.6 lm/mE

Grade DL (2nd Tier) · 15.4W/m

Grade DL (2nd Tier) · 15.4W/m — measured at 15.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K126.4 lm/W1946 lm/mE101.3 lm/W1559.6 lm/mF———
2300 K140.7 lm/W2166.2 lm/mD112.9 lm/W1738.2 lm/mE91.2 lm/W1404.1 lm/mF
2700 K148.6 lm/W2287.8 lm/mD122.1 lm/W1879.8 lm/mE99 lm/W1524.2 lm/mF
3000 K158.4 lm/W2438.7 lm/mD128.5 lm/W1978.3 lm/mE104.5 lm/W1608.8 lm/mF
3500 K160.8 lm/W2475.6 lm/mC130.8 lm/W2013.8 lm/mE107.7 lm/W1658.1 lm/mF
4000 K165.9 lm/W2554.1 lm/mC134 lm/W2063 lm/mE110.6 lm/W1702.8 lm/mE
5000 K165.7 lm/W2551.1 lm/mC133.9 lm/W2061.5 lm/mE110.9 lm/W1707.4 lm/mE
6500 K151.8 lm/W2337.1 lm/mD128.5 lm/W1978.3 lm/mE106.6 lm/W1641.2 lm/mF

Grade DL (2nd Tier) · 19.2W/m

Grade DL (2nd Tier) · 19.2W/m — measured at 19.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K123 lm/W2362.3 lm/mE98.6 lm/W1893.2 lm/mF———
2300 K137 lm/W2629.5 lm/mD109.9 lm/W2110 lm/mF88.8 lm/W1704.4 lm/mF
2700 K144.6 lm/W2777.2 lm/mD118.9 lm/W2281.9 lm/mE96.4 lm/W1850.2 lm/mF
3000 K154.2 lm/W2960.3 lm/mD125.1 lm/W2401.5 lm/mE101.7 lm/W1953 lm/mF
3500 K156.5 lm/W3005.2 lm/mD127.3 lm/W2444.5 lm/mE104.8 lm/W2012.8 lm/mF
4000 K161.5 lm/W3100.5 lm/mC130.4 lm/W2504.3 lm/mE107.7 lm/W2067 lm/mF
5000 K161.3 lm/W3096.8 lm/mC130.3 lm/W2502.5 lm/mE107.9 lm/W2072.6 lm/mF
6500 K147.8 lm/W2837 lm/mD125.1 lm/W2401.5 lm/mE103.8 lm/W1992.2 lm/mF

Grade DN (1st Tier) · 9.6W/m

Grade DN (1st Tier) · 9.6W/m — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K142 lm/W1363.5 lm/mE119.6 lm/W1148.6 lm/mE———
2300 K154.8 lm/W1486.5 lm/mD133.5 lm/W1281.5 lm/mE107.9 lm/W1035.6 lm/mF
2700 K166.9 lm/W1602.4 lm/mD144.5 lm/W1387.5 lm/mE117.1 lm/W1124.6 lm/mF
3000 K175.4 lm/W1683.4 lm/mC152.5 lm/W1464.5 lm/mD124 lm/W1190.6 lm/mE
3500 K178 lm/W1708.4 lm/mC155.9 lm/W1496.5 lm/mD128.3 lm/W1231.6 lm/mE
4000 K181.3 lm/W1740.4 lm/mC156.7 lm/W1504.5 lm/mD129.3 lm/W1241.6 lm/mE
5000 K181 lm/W1737.4 lm/mC157.8 lm/W1514.5 lm/mD130.6 lm/W1253.5 lm/mE
6500 K173.5 lm/W1665.4 lm/mC150.8 lm/W1447.5 lm/mD125.2 lm/W1201.6 lm/mE

Grade DN (1st Tier) · 15.4W/m

Grade DN (1st Tier) · 15.4W/m — measured at 15.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K136.4 lm/W2100 lm/mE114.9 lm/W1769 lm/mF———
2300 K148.7 lm/W2289.3 lm/mD128.2 lm/W1973.7 lm/mE103.6 lm/W1595 lm/mF
2700 K160.3 lm/W2467.9 lm/mD138.8 lm/W2136.9 lm/mE112.5 lm/W1732 lm/mF
3000 K168.4 lm/W2592.6 lm/mD146.5 lm/W2255.5 lm/mD119.1 lm/W1833.6 lm/mE
3500 K170.9 lm/W2631.1 lm/mD149.7 lm/W2304.7 lm/mD123.2 lm/W1896.7 lm/mE
4000 K174.1 lm/W2680.4 lm/mC150.5 lm/W2317 lm/mD124.2 lm/W1912.1 lm/mE
5000 K173.8 lm/W2675.8 lm/mC151.5 lm/W2332.4 lm/mD125.4 lm/W1930.6 lm/mE
6500 K166.6 lm/W2564.9 lm/mD144.8 lm/W2229.3 lm/mE120.2 lm/W1850.6 lm/mE

Grade DN (1st Tier) · 19.2W/m

Grade DN (1st Tier) · 19.2W/m — measured at 19.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K132.8 lm/W2549.2 lm/mE111.8 lm/W2147.4 lm/mF———
2300 K144.7 lm/W2779.1 lm/mE124.8 lm/W2395.9 lm/mE100.8 lm/W1936.2 lm/mF
2700 K156 lm/W2995.8 lm/mD135.1 lm/W2594 lm/mE109.5 lm/W2102.5 lm/mF
3000 K163.9 lm/W3147.2 lm/mD142.6 lm/W2737.9 lm/mE115.9 lm/W2225.9 lm/mF
3500 K166.4 lm/W3194 lm/mD145.7 lm/W2797.7 lm/mE119.9 lm/W2302.5 lm/mE
4000 K169.5 lm/W3253.8 lm/mD146.5 lm/W2812.7 lm/mD120.9 lm/W2321.2 lm/mE
5000 K169.2 lm/W3248.2 lm/mD147.5 lm/W2831.4 lm/mD122.1 lm/W2343.6 lm/mE
6500 K162.2 lm/W3113.6 lm/mD140.9 lm/W2706.2 lm/mE117 lm/W2246.4 lm/mF

Grade KE (3rd Tier) · 9.6W/m

Grade KE (3rd Tier) · 9.6W/m — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K110.5 lm/W1060.6 lm/mE88.4 lm/W848.7 lm/mF———
2300 K123.2 lm/W1182.6 lm/mE98.5 lm/W945.7 lm/mF79.7 lm/W764.7 lm/mG
2700 K132.8 lm/W1274.5 lm/mE106.9 lm/W1026.6 lm/mF86.6 lm/W831.7 lm/mF
3000 K139.4 lm/W1338.5 lm/mD113 lm/W1084.6 lm/mE91.8 lm/W881.7 lm/mF
3500 K141.5 lm/W1358.5 lm/mD115.2 lm/W1105.6 lm/mE94.9 lm/W910.7 lm/mF
4000 K145.7 lm/W1398.5 lm/mD117.7 lm/W1129.6 lm/mE97.2 lm/W932.7 lm/mF
5000 K145.5 lm/W1396.5 lm/mD117.7 lm/W1129.6 lm/mE97.4 lm/W934.7 lm/mF
6500 K139.4 lm/W1338.5 lm/mD113 lm/W1084.6 lm/mE93.7 lm/W899.7 lm/mF

Grade KE (3rd Tier) · 15.4W/m

Grade KE (3rd Tier) · 15.4W/m — measured at 15.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K106.1 lm/W1633.5 lm/mF84.9 lm/W1307.1 lm/mG———
2300 K118.3 lm/W1821.3 lm/mE94.6 lm/W1456.4 lm/mF76.5 lm/W1177.8 lm/mG
2700 K127.5 lm/W1962.9 lm/mE102.7 lm/W1581.1 lm/mF83.2 lm/W1280.9 lm/mG
3000 K133.9 lm/W2061.5 lm/mE108.5 lm/W1670.4 lm/mF88.2 lm/W1357.9 lm/mF
3500 K135.9 lm/W2092.3 lm/mD110.6 lm/W1702.8 lm/mE91.1 lm/W1402.5 lm/mF
4000 K139.9 lm/W2153.9 lm/mD113 lm/W1739.7 lm/mE93.3 lm/W1436.4 lm/mF
5000 K139.7 lm/W2150.8 lm/mD113 lm/W1739.7 lm/mE93.5 lm/W1439.5 lm/mF
6500 K133.9 lm/W2061.5 lm/mE108.5 lm/W1670.4 lm/mF90 lm/W1385.6 lm/mF

Grade KE (3rd Tier) · 19.2W/m

Grade KE (3rd Tier) · 19.2W/m — measured at 19.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K103.3 lm/W1982.9 lm/mF82.6 lm/W1586.7 lm/mG———
2300 K115.2 lm/W2210.9 lm/mE92.1 lm/W1768 lm/mF74.5 lm/W1429.7 lm/mG
2700 K124.1 lm/W2382.8 lm/mE100 lm/W1919.4 lm/mF81 lm/W1554.9 lm/mG
3000 K130.3 lm/W2502.5 lm/mE105.6 lm/W2027.8 lm/mF85.9 lm/W1648.4 lm/mF
3500 K132.3 lm/W2539.8 lm/mE107.7 lm/W2067 lm/mF88.7 lm/W1702.6 lm/mF
4000 K136.2 lm/W2614.6 lm/mD110 lm/W2111.9 lm/mF90.8 lm/W1743.7 lm/mF
5000 K136 lm/W2610.9 lm/mD110 lm/W2111.9 lm/mF91 lm/W1747.4 lm/mF
6500 K130.3 lm/W2502.5 lm/mE105.6 lm/W2027.8 lm/mF87.6 lm/W1682 lm/mF

High-Power LED Strip: Heat Dissipation & Aluminum Channel Guide

At up to 19.2W/m, 7923-PU is a high-power SMD LED strip. Above roughly 14.4W/m the tape can no longer shed its own heat through the FPC alone — an aluminum channel is part of the luminaire, not an accessory.

Why high-wattage strips need a heat sink

  • Aluminum conducts heat roughly 30× faster than the plastics, MDF or gypsum a strip is usually stuck to, so a bare high-power run traps heat under the tape.
  • LED lifetime (LM-80 / TM-21) is driven by solder-point temperature Tc. Keeping Tc inside the datasheet limit — DENO strips are rated Tc ≤ 75°C — is what preserves the rated L70 lifetime and colour stability.
  • Never run 14.4W/m or more coiled on the reel, inside a sealed plastic diffuser, or directly on wood, wallpaper or foam.

Sizing rule: FPC width vs channel inner width

  • Channel inner width ≥ FPC width + 2mm. This strip is 10mm wide, so it needs at least 12mm of inner width.
  • The 2mm clearance absorbs extrusion tolerance and lets the tape be seated or replaced without scraping the side walls or the wiring.
  • A frosted or opal PC cover then diffuses the higher lumen output into an even, dot-free line instead of visible hot spots.

Aluminum channels that fit this strip

Recommended LED Channels

Mount this LED strip in a DENO LED aluminum profile for heat dissipation, physical protection and diffused, dot-free output.

This strip is 10mm wide, so it needs a channel with at least 12mm inner width (10mm + 2mm clearance). Every profile below meets that.

Perguntas Frequentes

Quais são as principais especificações do 7923-PU?

7923-PU: 2835, 128, 24V, PCB de 10mm, FPCB de cobre de 3 oz, corte a cada 8LEDs/62.5mm, IP68PU, IRC (CRI) Ra≥80 , Ra≥90 , Ra≥95 , FS. Dados fotométricos completos, diagramas de ligação e relatórios de ensaio estão disponíveis na seção de downloads desta página.

Para quais ambientes esta Fita de LED para uso marítimo é classificada?

O grau de proteção contra ingresso deste modelo é IP68PU. Como Fita de LED para uso marítimo, ela é especificada para as condições de serviço indicadas na ficha técnica, e a DENO pode fornecer revestimentos alternativos, capas ou encapsulamento IP68 para instalações mais severas.

A DENO pode personalizar esta Fita de LED para uso marítimo para um projeto?

Sim. A DENO fabrica a série de Fitas SMD para uso marítimo como fornecedora OEM e ODM: comprimento do rolo, temperatura de cor, nível de IRC (CRI), largura da PCB, impermeabilização e identificação com marca própria podem ser especificados. Solicite um Orçamento para consultar o prazo de entrega e os preços do projeto.

O que torna uma Fita de LED adequada para uso marítimo?

Fitas de LED para uso marítimo precisam de encapsulamento IP67 ou IP68, revestimento resistente à névoa salina, condutores de cobre estanhado e silicone estável sob radiação UV. Essas Fitas de LED para embarcações são construídas para exposição contínua a borrifos de água salgada e vibração, em vez das condições de respingos leves para as quais uma fita impermeável convencional é classificada.

Qual Driver / Fonte de Alimentação de LED e qual comprimento de trecho são adequados para o #7923-PU?

Fita de LED 2835 PU de alta eficácia luminosa | 10mm | 24V | 128LEDs | 62.5mm/corte | #7923-PU é uma fita de corrente constante (CI de corrente constante integrado na placa) com entrada de 24V; portanto, alimente-a com um Driver / Fonte de Alimentação de LED de tensão constante de 24V com certificação CE ou UL e potência nominal cerca de 20% acima da carga conectada. O trecho único máximo é de 5m. Alimentação por uma extremidade: 5m / por ambas as extremidades: 10m. Alimentar por ambas as extremidades ou pelo meio reduz pela metade a distância percorrida no cobre e reduz a queda de tensão a aproximadamente um quarto.