DENO LED Lighting

Fita de LED 2835 de Corrente Constante e Alta Eficácia Luminosa (#7923)

8mm · 24V · 128LEDs · 62.5cut

Model: 7923

7923 Fita de LED 2835 de Corrente Constante e Alta Eficácia Luminosa — 24V, corte a cada 62,5 mm, FPCB de 8 mm, LEDs 2835, 128 LEDs/m, IP20Desenho dimensional 7923 Fita de LED 2835 de Corrente Constante e Alta Eficácia Luminosa — FPCB de 8 mm, corte a cada 62,5 mm, 24V7923 Fita de LED 2835 de Corrente Constante e Alta Eficácia Luminosa — 24V, corte a cada 62,5 mm, FPCB de 8 mm, LEDs 2835, 128 LEDs/m, IP20 (vista 3)7923 Fita de LED 2835 de Corrente Constante e Alta Eficácia Luminosa — 24V, corte a cada 62,5 mm, FPCB de 8 mm, LEDs 2835, 128 LEDs/m, IP20 (vista 4)7923 Fita de LED 2835 de Corrente Constante e Alta Eficácia Luminosa — 24V, corte a cada 62,5 mm, FPCB de 8 mm, LEDs 2835, 128 LEDs/m, IP20 (vista 5)

Visão Geral

10mm | 24V | 128LEDs | 62.5cut | #7923 | Fita de LED 2835 de Corrente Constante e Alta Eficácia Luminosa faz parte da série DENO de Fitas SMD C.C. (Reguladas por IC), desenvolvida com base em Fita de LED com IC de corrente constante. Especificações principais: 2835, 128LEDs/m, 24V, PCB de 8mm, FPCB de cobre de 3 oz, corte a cada 8LEDs/62.5mm. Cada rolo é produzido na linha rolo a rolo da DENO com FPCB de cobre com pureza de 99.9% e é fornecido em conformidade com CE, UL e RoHS para projetos arquitetônicos, de varejo e de hotelaria. Configurações OEM e ODM de comprimento, temperatura de cor e impermeabilização estão disponíveis sob consulta.

Descrição

Projetada com chips SMD 2835, esta Fita de LED de corrente constante de 24V oferece iluminação linear uniforme em trechos contínuos de até 5 metros. A PCB robusta com cobre de 3 oz e o encapsulamento com fios de ouro de pureza de 99.9% garantem dissipação térmica confiável e operação durável. Com 128 LEDs por metro e intervalos de corte de 62.5mm, o formato de 8mm de largura se integra facilmente a projetos de iluminação arquitetônica. Com dimerização suave e ângulo de abertura de 120 graus, este circuito flexível está disponível diretamente da fábrica para fornecimento de projetos no atacado.

We use 99.99% gold wire, large-size chips, and thickened FPCB, backed by a 5-year warranty.

Especificações

LED QTY128LEDs/m
PART NODL-F28A64V24-7923-*
SMD TYPE2835
UNIDADE DE CORTE8LEDs/62.5mm
DIMERIZÁVELYes
GRAU DE PROTEÇÃO IPIP20
LED PITCH7.8mm
LARGURA DA PCB8mm
ÂNGULO DE FACHO120°
COMPRIMENTO DO TRECHO5m
COPPER FOIL3 oz
ON OFF TIMES10000(test times)
POWER RANGE3.8~19.2W
TIPO DE CIRCUITOC.C.
INPUT VOLTAGE24V
MIN BEND DIAMETERΦ60mm
OPERATING TEMPERATURE-25~40°C;Tc: 75°C (max)

Aplicações

  • Sancas, banho de luz em paredes e perímetros — Sancas, rebaixos, detalhes de banho de luz e perímetros de teto que exigem uma linha de luz contínua e uniforme.
  • Iluminação de exposição em showrooms e hotelaria — Prateleiras, vitrines, balcões de recepção e retroiluminação de letreiros em lojas, showrooms e espaços de hotelaria.
  • Iluminação sob armários de cozinha e closets — Iluminação de tarefa em cozinhas, closets e móveis, onde a fita fica oculta e apenas a luz é vista.

Acessórios recomendados e peças compatíveis

  • DL-1215 — 12x15mm Surface Mount LED Channel — Tall U Shape Aluminum Profile: Accepts LED strips up to 8mm wide.
  • DL-1313HX-M — 13x13mm Magnetic Cabinet LED Channel — Tool-Free Corner Aluminum Profile: Accepts LED strips up to 8mm wide.
  • DL-1408 HX — 14x8mm Surface Mount LED Channel — Slim Aluminum Profile for 8mm Strip: Accepts LED strips up to 8mm wide.
  • DN-PSU-100 — 24V 100W Class-2 LED Driver · High Efficiency: Matches the 24V DC input of this strip; size the driver with at least 20% headroom over total load.
  • DN-PSU-150 — 24V 150W Class-2 LED Driver · Premium: Matches the 24V DC input of this strip; size the driver with at least 20% headroom over total load.
  • DN-PSU-60 — 24V 60W Class-2 LED Driver · Constant Voltage: Matches the 24V DC input of this strip; size the driver with at least 20% headroom over total load.
  • V1 — 5-36VDC 1-Channel * 8A RF+Push Dimming Controller | V1: Matched by input voltage range and colour channels.

Solicite um orçamento para #7923

A DENO LED é uma fabricante de fitas de LED com sede em Shenzhen e base de produção própria em Foshan. Envie-nos o comprimento do trecho, tensão, CCT/IRC e grau de proteção IP que você precisa e nossa equipe de engenharia responderá com uma ficha técnica, diagrama de fiação e preço — OEM/ODM e projetos totalmente personalizados incluídos.

Garantia
Conforme a ficha técnica do modelo
Prazo de entrega
Amostras personalizadas: 3–5 dias úteis · novo desenvolvimento: 1–3 semanas · produção em série: 1–2 semanas após aprovação da amostra
Conformidade
CE · RoHS · UL/ETL conforme o modelo e o mercado
Fio de ligação
Ouro puro 99,99%
Folha de cobre
FPCB de cobre puro 99,9%
Serviços
CCT, IRC, largura de PCB, unidade de corte e embalagem personalizadas — amostras e produção em massa de uma única fábrica.

Desempenho Fotométrico — Matriz de Eficácia CCT × IRC (CRI)

Peak measured luminous efficacy: 201.3 lm/W at 4000K, Ra 80, ErP energy class B (Grade DN (1st Tier)).

All values are measured at the stated power density and ambient 25 °C, reported as luminous efficacy in lumens per watt (lm/W), luminous flux per metre (lm/m) and the corresponding EU ErP (2019/2015) energy class.

Grade DL (2nd Tier)

Grade DL (2nd Tier) — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K149.7 lm/W1437.5 lm/mD120.2 lm/W1154.2 lm/mE———
2300 K166.7 lm/W1600.7 lm/mC133.9 lm/W1285.8 lm/mE108.5 lm/W1041.6 lm/mF
2700 K176.5 lm/W1694.9 lm/mC144.9 lm/W1391.4 lm/mD117.4 lm/W1127.3 lm/mE
3000 K187.7 lm/W1801.4 lm/mB152.5 lm/W1464.4 lm/mD124 lm/W1190.7 lm/mE
3500 K190.5 lm/W1828.3 lm/mB155.2 lm/W1490.3 lm/mD127.7 lm/W1226.2 lm/mE
4000 K196.6 lm/W1886.9 lm/mB159 lm/W1526.8 lm/mD131.2 lm/W1259.9 lm/mE
5000 K196.3 lm/W1884 lm/mB158.9 lm/W1525.8 lm/mD131.1 lm/W1258.6 lm/mE
6500 K180 lm/W1728.5 lm/mC152.4 lm/W1463.4 lm/mD126.5 lm/W1214.4 lm/mE

Grade DL (2nd Tier)

Grade DL (2nd Tier) — measured at 15.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K143.8 lm/W2213.9 lm/mD115.4 lm/W1777.7 lm/mE———
2300 K160.1 lm/W2465.3 lm/mC128.6 lm/W1980.3 lm/mE104.2 lm/W1604.7 lm/mF
2700 K169.5 lm/W2610.3 lm/mC139.2 lm/W2142.9 lm/mD112.7 lm/W1736.2 lm/mE
3000 K180.2 lm/W2774.4 lm/mC146.5 lm/W2255.3 lm/mD119.1 lm/W1833.9 lm/mE
3500 K182.8 lm/W2815.8 lm/mC149 lm/W2295.3 lm/mD122.6 lm/W1888.6 lm/mE
4000 K188.7 lm/W2906.1 lm/mB152.7 lm/W2351.5 lm/mD126 lm/W1940.3 lm/mE
5000 K188.4 lm/W2901.6 lm/mB152.6 lm/W2350 lm/mD125.9 lm/W1938.9 lm/mE
6500 K172.9 lm/W2662 lm/mC146.4 lm/W2253.9 lm/mD121.5 lm/W1871.1 lm/mE

Grade DL (2nd Tier)

Grade DL (2nd Tier) — measured at 19.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K140 lm/W2687.5 lm/mD112.4 lm/W2157.9 lm/mE———
2300 K155.9 lm/W2992.7 lm/mD125.2 lm/W2403.9 lm/mE101.4 lm/W1946.9 lm/mF
2700 K165 lm/W3168.7 lm/mC135.5 lm/W2601.3 lm/mD109.8 lm/W2107.6 lm/mF
3000 K175.4 lm/W3367.9 lm/mC142.6 lm/W2737.8 lm/mD115.9 lm/W2226.1 lm/mE
3500 K178 lm/W3418.2 lm/mC145.1 lm/W2786.3 lm/mD119.4 lm/W2292.6 lm/mE
4000 K183.7 lm/W3527.7 lm/mC148.7 lm/W2854.5 lm/mD122.7 lm/W2355.4 lm/mE
5000 K183.5 lm/W3522.3 lm/mC148.6 lm/W2852.7 lm/mD122.6 lm/W2353.9 lm/mE
6500 K168.3 lm/W3231.5 lm/mC142.5 lm/W2736 lm/mD118.3 lm/W2271.4 lm/mE

Grade DN (1st Tier)

Grade DN (1st Tier) — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K157.7 lm/W1514.1 lm/mD133 lm/W1277.3 lm/mE———
2300 K172 lm/W1651.2 lm/mD148.4 lm/W1424.9 lm/mD120.2 lm/W1153.9 lm/mE
2700 K185.4 lm/W1779.7 lm/mC160.7 lm/W1542.9 lm/mD130.3 lm/W1250.4 lm/mE
3000 K194.7 lm/W1868.9 lm/mC169.6 lm/W1628.2 lm/mD137.9 lm/W1324.3 lm/mE
3500 K197.6 lm/W1896.7 lm/mC173.3 lm/W1663.7 lm/mC142.6 lm/W1369.3 lm/mE
4000 K201.3 lm/W1932.2 lm/mB174.2 lm/W1672.3 lm/mC143.8 lm/W1380.8 lm/mE
5000 K201 lm/W1929.3 lm/mB175.4 lm/W1683.8 lm/mC144.7 lm/W1389.1 lm/mE
6500 K192.7 lm/W1849.7 lm/mC167.6 lm/W1609 lm/mD139.1 lm/W1335.4 lm/mE

Grade DN (1st Tier)

Grade DN (1st Tier) — measured at 15.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K151.4 lm/W2331.9 lm/mD127.7 lm/W1967.1 lm/mE———
2300 K165.1 lm/W2543.1 lm/mD142.5 lm/W2194.6 lm/mE115.4 lm/W1777.2 lm/mF
2700 K178 lm/W2741 lm/mC154.3 lm/W2376.2 lm/mD125.1 lm/W1925.8 lm/mE
3000 K186.9 lm/W2878.4 lm/mC162.8 lm/W2507.7 lm/mD132.4 lm/W2039.5 lm/mE
3500 K189.7 lm/W2921.2 lm/mC166.4 lm/W2562.3 lm/mD136.9 lm/W2108.9 lm/mE
4000 K193.2 lm/W2975.8 lm/mC167.2 lm/W2575.6 lm/mD138.1 lm/W2126.6 lm/mE
5000 K192.9 lm/W2971.4 lm/mC168.4 lm/W2593.3 lm/mD138.9 lm/W2139.1 lm/mE
6500 K185 lm/W2848.8 lm/mC160.9 lm/W2478.1 lm/mD133.6 lm/W2057.4 lm/mE

Grade DN (1st Tier)

Grade DN (1st Tier) — measured at 19.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K147.4 lm/W2830.8 lm/mD124.4 lm/W2387.9 lm/mE———
2300 K160.8 lm/W3087.1 lm/mD138.8 lm/W2664 lm/mE112.4 lm/W2158.1 lm/mF
2700 K173.3 lm/W3327.3 lm/mC150.2 lm/W2884.5 lm/mD121.8 lm/W2337.7 lm/mE
3000 K182 lm/W3494.1 lm/mC158.5 lm/W3044.1 lm/mD128.9 lm/W2475.8 lm/mE
3500 K184.7 lm/W3546.1 lm/mC162 lm/W3110.4 lm/mD133.3 lm/W2560 lm/mE
4000 K188.1 lm/W3612.4 lm/mC162.8 lm/W3126.6 lm/mD134.5 lm/W2581.6 lm/mE
5000 K187.9 lm/W3607 lm/mC164 lm/W3148.1 lm/mD135.3 lm/W2597.8 lm/mE
6500 K180.1 lm/W3458.2 lm/mC156.7 lm/W3008.2 lm/mD130 lm/W2496 lm/mE

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K129.6 lm/W1244.5 lm/mE103.9 lm/W997.7 lm/mF———
2300 K144.4 lm/W1386.6 lm/mD115.8 lm/W1111.9 lm/mE93.8 lm/W900.5 lm/mF
2700 K155.7 lm/W1495.1 lm/mD125.7 lm/W1207 lm/mE101.9 lm/W978.5 lm/mF
3000 K163.5 lm/W1570 lm/mC132.8 lm/W1275.2 lm/mE108 lm/W1037 lm/mF
3500 K165.9 lm/W1593 lm/mC135.4 lm/W1300.2 lm/mD111.4 lm/W1069.7 lm/mE
4000 K170.8 lm/W1640.1 lm/mC138.3 lm/W1328 lm/mD114.1 lm/W1095.6 lm/mE
5000 K170.6 lm/W1638.2 lm/mC138.2 lm/W1327 lm/mD114 lm/W1094.4 lm/mE
6500 K163.5 lm/W1570 lm/mC132.7 lm/W1274.2 lm/mE110.2 lm/W1057.9 lm/mE

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 15.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K124.5 lm/W1916.6 lm/mE99.8 lm/W1536.5 lm/mF———
2300 K138.7 lm/W2135.5 lm/mD111.2 lm/W1712.5 lm/mE90.1 lm/W1387.5 lm/mF
2700 K149.5 lm/W2302.6 lm/mD120.7 lm/W1858.9 lm/mE97.9 lm/W1507 lm/mF
3000 K157 lm/W2418 lm/mD127.5 lm/W1963.9 lm/mE103.7 lm/W1597.2 lm/mF
3500 K159.3 lm/W2453.4 lm/mD130 lm/W2002.4 lm/mE107 lm/W1647.5 lm/mF
4000 K164 lm/W2525.9 lm/mC132.8 lm/W2045.3 lm/mE109.6 lm/W1687.4 lm/mF
5000 K163.8 lm/W2523 lm/mC132.7 lm/W2043.8 lm/mE109.5 lm/W1686.3 lm/mF
6500 K157 lm/W2418 lm/mD127.4 lm/W1962.5 lm/mE105.8 lm/W1629.3 lm/mF

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 19.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K121.2 lm/W2326.6 lm/mE97.1 lm/W1865.2 lm/mF———
2300 K135 lm/W2592.3 lm/mD108.3 lm/W2078.9 lm/mF87.7 lm/W1683.8 lm/mF
2700 K145.6 lm/W2795.2 lm/mD117.5 lm/W2256.6 lm/mE95.3 lm/W1829.3 lm/mF
3000 K152.9 lm/W2935.2 lm/mD124.2 lm/W2384.1 lm/mE101 lm/W1938.8 lm/mF
3500 K155.1 lm/W2978.3 lm/mD126.6 lm/W2430.7 lm/mE104.2 lm/W1999.9 lm/mF
4000 K159.7 lm/W3066.2 lm/mD129.3 lm/W2482.8 lm/mE106.7 lm/W2048.3 lm/mF
5000 K159.5 lm/W3062.6 lm/mD129.2 lm/W2481 lm/mE106.6 lm/W2046.7 lm/mF
6500 K152.9 lm/W2935.2 lm/mD124.1 lm/W2382.3 lm/mE103 lm/W1977.6 lm/mF

High-Power LED Strip: Heat Dissipation & Aluminum Channel Guide

At up to 19.2W/m, 7923 is a high-power SMD LED strip. Above roughly 14.4W/m the tape can no longer shed its own heat through the FPC alone — an aluminum channel is part of the luminaire, not an accessory.

Why high-wattage strips need a heat sink

  • Aluminum conducts heat roughly 30× faster than the plastics, MDF or gypsum a strip is usually stuck to, so a bare high-power run traps heat under the tape.
  • LED lifetime (LM-80 / TM-21) is driven by solder-point temperature Tc. Keeping Tc inside the datasheet limit — DENO strips are rated Tc ≤ 75°C — is what preserves the rated L70 lifetime and colour stability.
  • Never run 14.4W/m or more coiled on the reel, inside a sealed plastic diffuser, or directly on wood, wallpaper or foam.

Sizing rule: FPC width vs channel inner width

  • Channel inner width ≥ FPC width + 2mm. This strip is 8mm wide, so it needs at least 10mm of inner width.
  • The 2mm clearance absorbs extrusion tolerance and lets the tape be seated or replaced without scraping the side walls or the wiring.
  • A frosted or opal PC cover then diffuses the higher lumen output into an even, dot-free line instead of visible hot spots.

Aluminum channels that fit this strip

Recommended LED Channels

Mount this LED strip in a DENO LED aluminum profile for heat dissipation, physical protection and diffused, dot-free output.

This strip is 8mm wide, so it needs a channel with at least 10mm inner width (8mm + 2mm clearance). Every profile below meets that.

Perguntas Frequentes

Quais dados estão registrados para o modelo 7923?

tensão: 24V; largura da PCB: 8mm; LEDs: 128LEDs/m; encapsulamento: 2835; unidade de corte: 8LEDs/62.5mm; cobre: 3 oz. Consulte a ficha técnica para a configuração do pedido.

Como confirmar a potência e a alimentação do modelo 7923?

Confirme a configuração na tabela de parâmetros do produto antes de dimensionar a fonte. Não extrapole comprimentos, corrente ou condições térmicas sem validação da instalação.

Como solicitar a configuração do modelo 7923?

Informe o modelo e as necessidades do projeto no pedido de orçamento. Temperatura de cor, proteção, amostra e prazo devem ser confirmados para a configuração solicitada.

Engineering & selection guide

Bending limits, IP selection, voltage drop, cutting and the full buyer Q&A for this family are kept on the series page.