No Controller, Remote or App Needed · Wall-Switch CCT on 2-Wire 24V · 2700K / 6500K / 4000K · 12mm

Model: 5214

5214 Fita de LED 2835 com Branco Ajustável sem Controlador | Sem Controlador, Controle Remoto ou Aplicativo | 12mm | 24V | 168LEDs | 83.3mm/corte | #5214 — 24V, cuttable every 83.3mm, 12mm FPCB width, 2835 LEDs, 168 LEDs/m, IP20

Visão Geral

Fita de LED 2835 de Branco Ajustável Controlada por Interruptor | Sem Controle Remoto | 12mm | 24V | 168LEDs | 83.3mm/corte | #5214 faz parte da série de Fitas SMD Especiais da DENO, desenvolvida para Fitas de LED de aplicações especiais. Especificações principais: 2835, 168, 24V, PCB de 12mm, FPCB de cobre de 3oz, cortável a cada 14LEDs/83.33mm. Cada rolo é produzido na linha roll-to-roll da DENO com FPCB de cobre com pureza de 99.9% e fornecido em conformidade com CE, UL e RoHS para projetos arquitetônicos, de varejo e de hotelaria. Configurações OEM e ODM de comprimento, temperatura de cor e impermeabilização estão disponíveis mediante solicitação.

Descrição

Esta Fita de LED 2835 com branco ajustável permite alternar a temperatura de cor diretamente por um interruptor de parede convencional, sem necessidade de controladores externos ou controles remotos. Cada ciclo de desligamento e religamento alterna a sequência de temperatura de cor entre 2700K, 6500K e 4000K, proporcionando iluminação intuitiva com múltiplos tons de branco para instalações de iluminação arquitetônica. Projetada com PCB de cobre de 3oz e largura de 12mm, esta Fita de LED de tensão constante de 24V apresenta intervalos de corte precisos de 83.33mm e 168 LEDs por metro. Os LEDs SMD 2835 de bin único mantêm a consistência de cor abaixo de 3 SDCM ao longo de toda a extensão máxima de cinco metros, para desempenho óptico uniforme. Oferecemos suporte de fabricação direto da fábrica, com fornecimento confiável para projetos no atacado e integração de circuitos dimerizáveis para empresas especializadas em instalações elétricas.

We use 99.99% gold wire, large-size chips, and thickened FPCB, backed by a 5-year warranty.

Especificações

SDCM< 3 SDCM (Single Bin)
LED QTY168
PART NODL-F28A84V24-5214-*
SMD TYPE2835
CUTTABLE UNIT14LEDs/83.33mm
DIMMABLEYes
IP RATINGIP20
LED PITCH11.9mm
PCB WIDTH12mm
WARRANTY5 Years
BEAM ANGLE120°
RUN LENGTH5m
COPPER FOIL3oz
POWER RANGE12~35W
CIRCUIT TYPEC.V.
INPUT VOLTAGE24V
OPERATING TEMPERATURE-25~40°C;Tc:75°C(max)

How a standard wall switch changes the colour temperature

Need a similar version? Need another CCT sequence, width or density with switch-controlled colour change? Send your drawing or target specification and our engineers will confirm feasibility.

Sequência do Interruptor

Um interruptor de parede, três temperaturas de cor

  1. Ligar2700K
  2. Desl. → Lig.6500K
  3. Desl. → Lig.4000K
  4. Desl. → Lig.Volta para 2700K

Cada ciclo rápido de desligar-ligar avança para o próximo modo: branco quente 2700K, branco frio 6500K, e então branco neutro 4000K (ambos os canais ligados). A fita memoriza o último modo após ser desligada, e um dimmer pode ser adicionado no mesmo circuito de dois fios.

Controle Duplo em 2 Fios: TCC + Dimerização

Adicione um dimmer comum de 24V de canal único e o mesmo circuito cumpre ambas as funções: use o interruptor liga/desliga para alternar entre 2700K → 6500K → 4000K, e então gire ou deslize o dimmer para ajustar o brilho da temperatura de cor selecionada.

Vídeo do Teste de Bancada

Fonte de alimentação padrão 24V, dois fios de saída, sem controlador

Vídeo de bancada DENO: o plugue de energia é alternado; a fita é alimentada apenas por V+ e V− de uma fonte de alimentação comum de tensão constante.

Mesmo Ambiente, Três Climas

Cena ilustrativa de escritório iluminado em branco quente por uma fita de LED de branco dinâmico controlada por interruptorCena ilustrativa de escritório iluminado em branco frio por uma fita de LED de branco dinâmico controlada por interruptorCena ilustrativa de escritório iluminado em branco neutro por uma fita de LED de branco dinâmico controlada por interruptorBranco Quente · 2700K

Ilustração renderizada do efeito; a aparência real depende das luminárias e superfícies.

Fiação para Retrofit

Branco dinâmico convencional

  • 3 condutores (V+, WW−, CW−)
  • Controlador ou driver de TCC de dois canais
  • Controle remoto, app ou painel de controle
  • Novas passagens de cabo em edificações existentes

DENO #5214

  • 2 condutores (V+, V−)
  • Qualquer fonte de alimentação padrão 24V de tensão constante
  • Interruptor de parede comum
  • Reaproveita o circuito existente de dois fios

Aplicações

  • Cove, wall-wash & perimeter lighting — Coves, recesses, wall-wash details and ceiling perimeters where a continuous, uniform line of light is required.
  • Showroom & hospitality display lighting — Shelving, display cases, reception desks and signage backlighting in shops, showrooms and hospitality spaces.
  • Kitchen & wardrobe under-cabinet lighting — Kitchen, wardrobe and furniture task lighting where the strip stays hidden and only the light is seen.

Acessórios recomendados e peças compatíveis

  • DL-1201 — 25x14.5mm Wide Surface Mount LED Channel — Aluminum Profile for 12mm Strip: Accepts LED strips up to 12mm wide.
  • DL-1202 — 17.3x14.5mm Surface Mount LED Channel — Deep Aluminum Profile for 12mm Strip: Accepts LED strips up to 12mm wide.
  • DL-1204 — 25x7mm Wide Slim Surface Mount LED Channel — Dotless Aluminum Profile for 240 LEDs/m: Accepts LED strips up to 12mm wide.
  • DN-PSU-100 — 24V 100W Class-2 LED Driver · High Efficiency: Matches the 24V DC input of this strip; size the driver with at least 20% headroom over total load.
  • DN-PSU-150 — 24V 150W Class-2 LED Driver · Premium: Matches the 24V DC input of this strip; size the driver with at least 20% headroom over total load.
  • DN-PSU-60 — 24V 60W Class-2 LED Driver · Constant Voltage: Matches the 24V DC input of this strip; size the driver with at least 20% headroom over total load.
  • V2 — 12-24VDC 2-Channel * 5A Color Temperature Controller | V2: Matched by input voltage range and colour channels.

Solicite um orçamento para #5214

A DENO LED é uma fabricante de fitas de LED com sede em Shenzhen e base de produção própria em Foshan. Envie-nos o comprimento do trecho, tensão, CCT/IRC e grau de proteção IP que você precisa e nossa equipe de engenharia responderá com uma ficha técnica, diagrama de fiação e preço — OEM/ODM e projetos totalmente personalizados incluídos.

Garantia
5 anos
Prazo de entrega
Placas padrão: amostras a partir de 1 dia útil · personalizadas: 3–5 dias úteis · nova FPCB: 1–3 semanas · produção 1–2 semanas após aprovação da amostra
Conformidade
CE · ETL · UL · RoHS
Fio de ligação
Ouro puro 99,99%
Folha de cobre
FPCB de cobre puro 99,9%
Serviços
CCT, IRC, largura de PCB, unidade de corte e embalagem personalizadas — amostras e produção em massa de uma única fábrica.

Desempenho Fotométrico — Matriz de Eficácia CCT × IRC (CRI)

Peak measured luminous efficacy: 180.9 lm/W at 6500K, Ra 80, ErP energy class C (Grade DN (1st Tier) · CCT 3-Anchor · 12W/m).

All values are measured at the stated power density and ambient 25 °C, reported as luminous efficacy in lumens per watt (lm/W), luminous flux per metre (lm/m) and the corresponding EU ErP (2019/2015) energy class.

Grade DN (1st Tier) · CCT 3-Anchor · 12W/m

Grade DN (1st Tier) · CCT 3-Anchor · 12W/m — measured at 12 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
2700 K163.1 lm/W978.3 lm/mD132.4 lm/W794.6 lm/mE103.3 lm/W619.8 lm/mF
4000 K164.6 lm/W1975.6 lm/mD133.8 lm/W1605.7 lm/mE104.4 lm/W1252.2 lm/mF
6500 K180.9 lm/W1085.6 lm/mC147.2 lm/W883 lm/mD114.8 lm/W688.6 lm/mF

Grade DN (1st Tier) · CCT 3-Anchor · 14.4W/m

Grade DN (1st Tier) · CCT 3-Anchor · 14.4W/m — measured at 14.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
2700 K160.3 lm/W1154.4 lm/mD130.2 lm/W937.6 lm/mE101.6 lm/W731.3 lm/mF
4000 K161.9 lm/W2331 lm/mD131.6 lm/W1894.6 lm/mE102.6 lm/W1477.6 lm/mF
6500 K177.9 lm/W1281 lm/mC144.7 lm/W1041.9 lm/mE112.8 lm/W812.5 lm/mF

Grade DN (1st Tier) · CCT 3-Anchor · 19.2W/m

Grade DN (1st Tier) · CCT 3-Anchor · 19.2W/m — measured at 19.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
2700 K155 lm/W1488.1 lm/mD125.9 lm/W1208.7 lm/mE98.2 lm/W942.8 lm/mF
4000 K156.5 lm/W3005 lm/mD127.2 lm/W2442.4 lm/mE99.2 lm/W1904.8 lm/mF
6500 K172 lm/W1651.3 lm/mD139.9 lm/W1343.1 lm/mE109.1 lm/W1047.4 lm/mF

Grade DN (1st Tier) · CCT 3-Anchor · 22W/m

Grade DN (1st Tier) · CCT 3-Anchor · 22W/m — measured at 22 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
2700 K152 lm/W1671.9 lm/mD123.5 lm/W1358 lm/mE96.3 lm/W1059.2 lm/mF
4000 K153.5 lm/W3376.2 lm/mD124.7 lm/W2744.1 lm/mE97.3 lm/W2140 lm/mF
6500 K168.7 lm/W1855.3 lm/mD137.2 lm/W1509 lm/mE107 lm/W1176.8 lm/mF

Grade DL (2nd Tier) · CCT 3-Anchor · 12W/m

Grade DL (2nd Tier) · CCT 3-Anchor · 12W/m — measured at 12 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
2700 K140.1 lm/W840.7 lm/mD113.7 lm/W682.3 lm/mE88.7 lm/W532.1 lm/mF
4000 K141.6 lm/W1699.1 lm/mD114.9 lm/W1378.5 lm/mE89.6 lm/W1075.5 lm/mF
6500 K155.6 lm/W933.5 lm/mD126.3 lm/W758 lm/mE98.6 lm/W591.4 lm/mF

Grade DL (2nd Tier) · CCT 3-Anchor · 14.4W/m

Grade DL (2nd Tier) · CCT 3-Anchor · 14.4W/m — measured at 14.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
2700 K137.8 lm/W992 lm/mD111.8 lm/W805.1 lm/mE87.2 lm/W627.8 lm/mF
4000 K139.2 lm/W2004.8 lm/mD113 lm/W1626.5 lm/mE88.1 lm/W1269 lm/mF
6500 K153 lm/W1101.5 lm/mD124.2 lm/W894.4 lm/mE96.9 lm/W697.8 lm/mF

Grade DL (2nd Tier) · CCT 3-Anchor · 19.2W/m

Grade DL (2nd Tier) · CCT 3-Anchor · 19.2W/m — measured at 19.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
2700 K133.2 lm/W1278.8 lm/mE108.1 lm/W1037.8 lm/mF84.3 lm/W809.3 lm/mG
4000 K134.6 lm/W2584.5 lm/mE109.2 lm/W2096.8 lm/mF85.2 lm/W1636 lm/mF
6500 K147.9 lm/W1419.9 lm/mD120.1 lm/W1153 lm/mE93.7 lm/W899.6 lm/mF

Grade DL (2nd Tier) · CCT 3-Anchor · 22W/m

Grade DL (2nd Tier) · CCT 3-Anchor · 22W/m — measured at 22 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
2700 K130.6 lm/W1436.8 lm/mE106 lm/W1166 lm/mF82.7 lm/W909.3 lm/mG
4000 K132 lm/W2903.7 lm/mE107.1 lm/W2355.8 lm/mF83.5 lm/W1838 lm/mG
6500 K145 lm/W1595.3 lm/mD117.8 lm/W1295.5 lm/mE91.9 lm/W1010.7 lm/mF

Grade KE (3rd Tier) · CCT 3-Anchor · 12W/m

Grade KE (3rd Tier) · CCT 3-Anchor · 12W/m — measured at 12 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
2700 K114.8 lm/W688.6 lm/mE92.9 lm/W557.3 lm/mF72.5 lm/W434.9 lm/mG
4000 K115.9 lm/W1391.1 lm/mE93.8 lm/W1126 lm/mF73.2 lm/W878.6 lm/mG
6500 K127.4 lm/W764.3 lm/mE103.2 lm/W619.2 lm/mF80.5 lm/W482.8 lm/mG

Grade KE (3rd Tier) · CCT 3-Anchor · 14.4W/m

Grade KE (3rd Tier) · CCT 3-Anchor · 14.4W/m — measured at 14.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
2700 K112.8 lm/W812.5 lm/mE91.3 lm/W657.6 lm/mF71.3 lm/W513.1 lm/mG
4000 K114 lm/W1641.4 lm/mE92.3 lm/W1328.6 lm/mF72 lm/W1036.7 lm/mG
6500 K125.3 lm/W901.9 lm/mE101.5 lm/W730.6 lm/mF79.1 lm/W569.7 lm/mG

Grade KE (3rd Tier) · CCT 3-Anchor · 19.2W/m

Grade KE (3rd Tier) · CCT 3-Anchor · 19.2W/m — measured at 19.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
2700 K109.1 lm/W1047.4 lm/mF88.3 lm/W847.7 lm/mF68.9 lm/W661.5 lm/mG
4000 K110.2 lm/W2116 lm/mE89.2 lm/W1712.8 lm/mF69.6 lm/W1336.4 lm/mG
6500 K121.1 lm/W1162.6 lm/mE98.1 lm/W941.8 lm/mF76.5 lm/W734.5 lm/mG

Grade KE (3rd Tier) · CCT 3-Anchor · 22W/m

Grade KE (3rd Tier) · CCT 3-Anchor · 22W/m — measured at 22 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
2700 K107 lm/W1176.8 lm/mF86.6 lm/W952.4 lm/mF67.6 lm/W743.2 lm/mG
4000 K108.1 lm/W2377.3 lm/mF87.5 lm/W1924.3 lm/mF68.2 lm/W1501.5 lm/mG
6500 K118.7 lm/W1306.2 lm/mE96.2 lm/W1058.2 lm/mF75 lm/W825.2 lm/mG

High-Power LED Strip: Heat Dissipation & Aluminum Channel Guide

At up to 22W/m, 5214 is a high-power SMD LED strip. Above roughly 14.4W/m the tape can no longer shed its own heat through the FPC alone — an aluminum channel is part of the luminaire, not an accessory.

Why high-wattage strips need a heat sink

  • Aluminum conducts heat roughly 30× faster than the plastics, MDF or gypsum a strip is usually stuck to, so a bare high-power run traps heat under the tape.
  • LED lifetime (LM-80 / TM-21) is driven by solder-point temperature Tc. Keeping Tc inside the datasheet limit — DENO strips are rated Tc ≤ 75°C — is what preserves the rated L70 lifetime and colour stability.
  • Never run 14.4W/m or more coiled on the reel, inside a sealed plastic diffuser, or directly on wood, wallpaper or foam.

Sizing rule: FPC width vs channel inner width

  • Channel inner width ≥ FPC width + 2mm. This strip is 12mm wide, so it needs at least 14mm of inner width.
  • The 2mm clearance absorbs extrusion tolerance and lets the tape be seated or replaced without scraping the side walls or the wiring.
  • A frosted or opal PC cover then diffuses the higher lumen output into an even, dot-free line instead of visible hot spots.

Aluminum channels that fit this strip

Recommended LED Channels

Mount this LED strip in a DENO LED aluminum profile for heat dissipation, physical protection and diffused, dot-free output.

This strip is 12mm wide, so it needs a channel with at least 14mm inner width (12mm + 2mm clearance). Every profile below meets that.

Modelos relacionados nesta série

See every model in SMD LED Strip Series or narrow to 2835. Compare wattage, lumen output and run length in the ProCalc parameter library, or request OEM/ODM pricing on the custom manufacturing page.

Perguntas Frequentes

Posso obter iluminação de branco ajustável sem instalar nenhum controlador?

Sim. Escolha a Fita de LED de branco ajustável controlada por interruptor da DENO (#5214). Um interruptor de parede comum altera a temperatura de cor: cada ciclo de desligar e ligar alterna entre branco quente de 2700K, branco frio de 6500K e branco neutro de 4000K em um circuito padrão de 24V com dois fios, sem controlador de Temperatura de Cor (CCT), controle remoto ou aplicativo.

Como a #5214 altera a temperatura de cor sem um controlador?

Desligar e ligar novamente a alimentação com um interruptor de parede padrão faz a fita avançar para o próximo branco na sequência: 2700K, depois 6500K e, em seguida, 4000K. Não é necessário controle remoto, aplicativo ou controlador de Temperatura de Cor (CCT).

Como a fita alterna a Temperatura de Cor (CCT) sem um fio de sinal?

Um IC lógico integrado à FPCB detecta o ciclo de alimentação realizado pelo interruptor de parede e comuta os LEDs para a próxima combinação de canais, dispensando um condutor de dados ou de controle.

Posso substituir uma fita monocromática de 24V existente por uma de branco ajustável sem trocar os dois fios?

Sim. A #5214 funciona com um único par V+/V- de um Driver / Fonte de Alimentação padrão de tensão constante de 24V, podendo substituir uma fita monocromática onde há apenas dois condutores instalados, sem passar novos cabos.

A #5214 memoriza a última temperatura de cor após uma queda de energia?

Sim. A fita armazena o último branco selecionado e retorna a ele quando a alimentação é restabelecida, mantendo a temperatura de cor preferida do ambiente após o desligamento ou uma interrupção de energia.