DENO LED Lighting

Fita de LED 2835 de Alta Eficácia Luminosa e Alto Fluxo Luminoso (#10162)

10mm · 24V · 180LEDs · 50mm/corte

Model: 10162

10162 10mm | 24V | 180LEDs | 50mm/corte | #10162 | Fita de LED 2835 de Alta Eficácia Luminosa e Alto Fluxo Luminoso — 24V, cuttable every 50mm, 10mm FPCB width, 2835 LEDs, 180 LEDs/m, IP20

Visão Geral

10mm | 24V | 180LEDs | 50mm/corte | #10162 | Fita de LED 2835 de Alta Eficácia Luminosa e Alto Fluxo Luminoso faz parte da série de Fitas SMD de Alta Eficácia Luminosa da DENO, desenvolvida com foco em Fitas de LED de alta eficácia luminosa. Principais especificações: 2835, 180 LEDs/m, DC 24V, PCB de 10mm, FPCB de cobre de 3oz, corte a cada 9LEDs/50mm. Cada rolo é produzido na linha rolo a rolo da DENO com FPCB de cobre com pureza de 99.9% e fornecido em conformidade com CE, UL e RoHS para projetos de arquitetura, varejo e hotelaria. Configurações OEM e ODM de comprimento, temperatura de cor e impermeabilização estão disponíveis mediante solicitação.

Descrição

Projetada com chips SMD 2835 de alta qualidade, esta Fita de LED de alta eficácia oferece até 228lm/W para projetos de iluminação arquitetônica comercial que exigem conformidade com ErP EcoDesign. Com uma disposição densa de 180 LEDs por metro e ângulo de abertura de 120 graus, a fita produz iluminação linear uniforme e sem pontos visíveis. A PCB robusta de 3oz e 10mm e o projeto de tensão constante de 24V garantem distribuição estável de energia ao longo de trechos completos de 5 metros, sem queda visível de brilho. Esta fita dimerizável oferece segmentos de corte precisos de 50mm com 9 LEDs, permitindo instalação flexível no local e comprimentos personalizados OEM para fornecimento de projetos no atacado.

High Efficacy Led Strip Lights built for high light efficacy smd strips projects.

Especificações

LED QTY180 LEDs/m
PART NODL-F28A90V24-10162-*
SMD TYPE2835
CUTTABLE UNIT9LEDs/50mm
DIMMABLEYes
IP RATINGIP20
LED PITCH5.5mm
PCB WIDTH10mm
BEAM ANGLE120°
RUN LENGTH5m
COPPER FOIL3oz
POWER RANGE2.4~28.8W
CIRCUIT TYPEC.V.
INPUT VOLTAGEDC 24V

Aplicações

  • Cove, wall-wash & perimeter lighting — Coves, recesses, wall-wash details and ceiling perimeters where a continuous, uniform line of light is required.
  • Showroom & hospitality display lighting — Shelving, display cases, reception desks and signage backlighting in shops, showrooms and hospitality spaces.
  • Kitchen & wardrobe under-cabinet lighting — Kitchen, wardrobe and furniture task lighting where the strip stays hidden and only the light is seen.

Acessórios recomendados e peças compatíveis

  • DL-1003 — 19.1x8mm Surface Mount LED Channel — Dotless Aluminum Profile for 240 LEDs/m Strip: Accepts LED strips up to 10mm wide.
  • DL-1103-1 — 16x13mm Surface Mount LED Channel — Aluminum Profile for 10mm LED Strip: Accepts LED strips up to 10mm wide.
  • DL-1510 HX-F — 15x9.9mm Recessed LED Channel with Flange — Flush Mount Aluminum Profile: Accepts LED strips up to 10mm wide.
  • DN-PSU-100 — 24V 100W Class-2 LED Driver · High Efficiency: Matches the 24V DC input of this strip; size the driver with at least 20% headroom over total load.
  • DN-PSU-150 — 24V 150W Class-2 LED Driver · Premium: Matches the 24V DC input of this strip; size the driver with at least 20% headroom over total load.
  • DN-PSU-60 — 24V 60W Class-2 LED Driver · Constant Voltage: Matches the 24V DC input of this strip; size the driver with at least 20% headroom over total load.
  • V1 — 5-36VDC 1-Channel * 8A RF+Push Dimming Controller | V1: Matched by input voltage range and colour channels.

Solicite um orçamento para #10162

A DENO LED é uma fabricante de fitas de LED com sede em Shenzhen e base de produção própria em Foshan. Envie-nos o comprimento do trecho, tensão, CCT/IRC e grau de proteção IP que você precisa e nossa equipe de engenharia responderá com uma ficha técnica, diagrama de fiação e preço — OEM/ODM e projetos totalmente personalizados incluídos.

Garantia
5 anos
Prazo de entrega
Placas padrão: amostras a partir de 1 dia útil · personalizadas: 3–5 dias úteis · nova FPCB: 1–3 semanas · produção 1–2 semanas após aprovação da amostra
Conformidade
CE · ETL · UL · RoHS
Fio de ligação
Ouro puro 99,99%
Folha de cobre
FPCB de cobre puro 99,9%
Serviços
CCT, IRC, largura de PCB, unidade de corte e embalagem personalizadas — amostras e produção em massa de uma única fábrica.

Desempenho Fotométrico — Matriz de Eficácia CCT × IRC (CRI)

Peak measured luminous efficacy: 230.2 lm/W at 4000K, Ra 80, ErP energy class A (Grade DN (1st Tier)).

All values are measured at the stated power density and ambient 25 °C, reported as luminous efficacy in lumens per watt (lm/W), luminous flux per metre (lm/m) and the corresponding EU ErP (2019/2015) energy class.

Grade DL (2nd Tier)

Grade DL (2nd Tier) — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K172.9 lm/W1659.4 lm/mC139 lm/W1334.4 lm/mD———
2300 K192.6 lm/W1848.6 lm/mB154.8 lm/W1486.5 lm/mD125.4 lm/W1203.8 lm/mE
2700 K204.2 lm/W1960.7 lm/mB167.6 lm/W1609.1 lm/mC135.8 lm/W1304 lm/mD
3000 K216.7 lm/W2080.5 lm/mA176.3 lm/W1692.7 lm/mC143.5 lm/W1377.2 lm/mD
3500 K219.9 lm/W2110.9 lm/mA179.5 lm/W1723.1 lm/mC147.7 lm/W1418 lm/mD
4000 K226.9 lm/W2178.4 lm/mA183.8 lm/W1764.9 lm/mC151.8 lm/W1457 lm/mD
5000 K226.6 lm/W2175.5 lm/mA183.7 lm/W1764 lm/mC151.6 lm/W1455.4 lm/mD
6500 K208.1 lm/W1997.8 lm/mB176.2 lm/W1691.7 lm/mC146.3 lm/W1404.5 lm/mD

Grade DL (2nd Tier)

Grade DL (2nd Tier) — measured at 12 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K170 lm/W2039.6 lm/mC136.7 lm/W1640.1 lm/mD———
2300 K189.3 lm/W2272.1 lm/mB152.3 lm/W1827 lm/mD123.3 lm/W1479.6 lm/mE
2700 K200.8 lm/W2409.9 lm/mB164.8 lm/W1977.7 lm/mC133.6 lm/W1602.7 lm/mE
3000 K213.1 lm/W2557.1 lm/mA173.4 lm/W2080.5 lm/mC141.1 lm/W1692.7 lm/mD
3500 K216.2 lm/W2594.5 lm/mA176.5 lm/W2117.9 lm/mC145.2 lm/W1742.9 lm/mD
4000 K223.1 lm/W2677.4 lm/mA180.8 lm/W2169.3 lm/mC149.2 lm/W1790.8 lm/mD
5000 K222.8 lm/W2673.9 lm/mA180.7 lm/W2168.1 lm/mC149.1 lm/W1789.2 lm/mD
6500 K204.6 lm/W2455.5 lm/mB173.3 lm/W2079.3 lm/mC143.8 lm/W1725.6 lm/mD

Grade DL (2nd Tier)

Grade DL (2nd Tier) — measured at 14.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K167.1 lm/W2406.6 lm/mC134.4 lm/W1935.2 lm/mE———
2300 K186.2 lm/W2680.9 lm/mB149.7 lm/W2155.8 lm/mD121.3 lm/W1746.7 lm/mE
2700 K197.5 lm/W2843.6 lm/mB162.1 lm/W2333.6 lm/mC131.3 lm/W1891.1 lm/mE
3000 K209.5 lm/W3017.2 lm/mB170.5 lm/W2454.9 lm/mC138.7 lm/W1997.2 lm/mD
3500 K212.6 lm/W3061.3 lm/mA173.5 lm/W2499 lm/mC142.8 lm/W2056.5 lm/mD
4000 K219.4 lm/W3159.2 lm/mA177.8 lm/W2559.6 lm/mC146.7 lm/W2113 lm/mD
5000 K219.1 lm/W3155.1 lm/mA177.7 lm/W2558.2 lm/mC146.6 lm/W2111 lm/mD
6500 K201.2 lm/W2897.3 lm/mB170.4 lm/W2453.5 lm/mC141.4 lm/W2036.2 lm/mD

Grade DL (2nd Tier)

Grade DL (2nd Tier) — measured at 19.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K161.6 lm/W3102.4 lm/mC129.9 lm/W2494.7 lm/mE———
2300 K180 lm/W3456 lm/mC144.7 lm/W2779 lm/mD117.2 lm/W2250.2 lm/mE
2700 K190.9 lm/W3665.7 lm/mB156.7 lm/W3008.3 lm/mD127 lm/W2437.9 lm/mE
3000 K202.6 lm/W3889.6 lm/mB164.8 lm/W3164.6 lm/mC134.1 lm/W2574.7 lm/mE
3500 K205.5 lm/W3946.4 lm/mB167.8 lm/W3221.5 lm/mC138.1 lm/W2651.1 lm/mD
4000 K212.1 lm/W4072.6 lm/mA171.9 lm/W3299.7 lm/mC141.9 lm/W2724 lm/mD
5000 K211.8 lm/W4067.3 lm/mA171.8 lm/W3297.9 lm/mC141.7 lm/W2720.6 lm/mD
6500 K194.5 lm/W3735 lm/mB164.7 lm/W3162.8 lm/mC136.7 lm/W2624.6 lm/mD

Grade DL (2nd Tier)

Grade DL (2nd Tier) — measured at 24 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K156.2 lm/W3749.5 lm/mD125.6 lm/W3015 lm/mE———
2300 K174 lm/W4176.8 lm/mC139.9 lm/W3358.6 lm/mD113.4 lm/W2721.6 lm/mE
2700 K184.6 lm/W4430.2 lm/mC151.5 lm/W3635.6 lm/mD122.8 lm/W2946.3 lm/mE
3000 K195.9 lm/W4700.8 lm/mB159.4 lm/W3824.6 lm/mD129.7 lm/W3111.7 lm/mE
3500 K198.7 lm/W4769.5 lm/mB162.2 lm/W3893.3 lm/mC133.5 lm/W3204 lm/mE
4000 K205.1 lm/W4922 lm/mB166.2 lm/W3987.8 lm/mC137.2 lm/W3292 lm/mD
5000 K204.8 lm/W4915.5 lm/mB166.1 lm/W3985.7 lm/mC137 lm/W3288 lm/mD
6500 K188.1 lm/W4513.9 lm/mB159.3 lm/W3822.5 lm/mD132.2 lm/W3172.8 lm/mE

Grade DN (1st Tier)

Grade DN (1st Tier) — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K180.4 lm/W1731.7 lm/mC152.4 lm/W1462.7 lm/mD———
2300 K196.7 lm/W1888.5 lm/mC170 lm/W1631.9 lm/mD137.7 lm/W1321.9 lm/mE
2700 K212 lm/W2034.8 lm/mB184 lm/W1766.8 lm/mC149.1 lm/W1431.3 lm/mD
3000 K222.7 lm/W2137.5 lm/mB194.1 lm/W1863.8 lm/mC157.9 lm/W1515.9 lm/mD
3500 K225.9 lm/W2168.9 lm/mB198.3 lm/W1903.7 lm/mC163.3 lm/W1567.2 lm/mD
4000 K230.2 lm/W2209.7 lm/mA199.5 lm/W1915.1 lm/mC164.6 lm/W1580.5 lm/mD
5000 K229.9 lm/W2206.9 lm/mA200.8 lm/W1927.4 lm/mB165.6 lm/W1589.8 lm/mD
6500 K220.4 lm/W2115.6 lm/mB191.9 lm/W1841.9 lm/mC159.2 lm/W1528.3 lm/mD

Grade DN (1st Tier)

Grade DN (1st Tier) — measured at 12 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K177.4 lm/W2128.4 lm/mC149.8 lm/W1797.8 lm/mD———
2300 K193.4 lm/W2321.1 lm/mC167.1 lm/W2005.7 lm/mD135.4 lm/W1624.8 lm/mE
2700 K208.4 lm/W2501 lm/mB181 lm/W2171.6 lm/mC146.6 lm/W1759.3 lm/mD
3000 K218.9 lm/W2627.2 lm/mB190.9 lm/W2290.8 lm/mC155.3 lm/W1863.2 lm/mD
3500 K222.1 lm/W2665.7 lm/mB195 lm/W2339.8 lm/mC160.5 lm/W1926.3 lm/mD
4000 K226.3 lm/W2716 lm/mB196.2 lm/W2353.8 lm/mC161.9 lm/W1942.7 lm/mD
5000 K226 lm/W2712.5 lm/mB197.4 lm/W2369 lm/mC162.9 lm/W1954.8 lm/mD
6500 K216.7 lm/W2600.3 lm/mB188.7 lm/W2263.9 lm/mC156.6 lm/W1879.2 lm/mD

Grade DN (1st Tier)

Grade DN (1st Tier) — measured at 14.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K174.4 lm/W2511.4 lm/mC147.3 lm/W2121.3 lm/mD———
2300 K190.2 lm/W2738.8 lm/mC164.4 lm/W2366.6 lm/mD133.1 lm/W1916.6 lm/mE
2700 K204.9 lm/W2951.1 lm/mB177.9 lm/W2562.4 lm/mC144.2 lm/W2075.8 lm/mE
3000 K215.3 lm/W3099.9 lm/mB187.7 lm/W2703 lm/mC152.7 lm/W2198.5 lm/mD
3500 K218.4 lm/W3145.4 lm/mB191.7 lm/W2760.9 lm/mC157.8 lm/W2272.9 lm/mD
4000 K222.5 lm/W3204.7 lm/mB192.9 lm/W2777.4 lm/mC159.2 lm/W2292.2 lm/mD
5000 K222.3 lm/W3200.6 lm/mB194.1 lm/W2795.3 lm/mC160.1 lm/W2305.4 lm/mD
6500 K213.1 lm/W3068.2 lm/mB185.5 lm/W2671.3 lm/mC154 lm/W2217.6 lm/mD

Grade DN (1st Tier)

Grade DN (1st Tier) — measured at 19.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K168.6 lm/W3237.5 lm/mD142.4 lm/W2734.6 lm/mE———
2300 K183.9 lm/W3530.7 lm/mC158.9 lm/W3050.9 lm/mD128.7 lm/W2471 lm/mE
2700 K198.1 lm/W3804.3 lm/mC172 lm/W3303.2 lm/mD139.4 lm/W2676 lm/mE
3000 K208.1 lm/W3996.2 lm/mB181.5 lm/W3484.5 lm/mC147.6 lm/W2834.1 lm/mD
3500 K211.2 lm/W4054.8 lm/mB185.4 lm/W3559.1 lm/mC152.6 lm/W2930.1 lm/mD
4000 K215.2 lm/W4131.2 lm/mB186.5 lm/W3580.4 lm/mC153.9 lm/W2954.9 lm/mD
5000 K214.9 lm/W4125.9 lm/mB187.7 lm/W3603.5 lm/mC154.8 lm/W2972.2 lm/mD
6500 K206 lm/W3955.3 lm/mB179.4 lm/W3443.6 lm/mC148.9 lm/W2858.9 lm/mD

Grade DN (1st Tier)

Grade DN (1st Tier) — measured at 24 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K163 lm/W3912.7 lm/mD137.7 lm/W3304.9 lm/mE———
2300 K177.8 lm/W4267 lm/mC153.6 lm/W3687.2 lm/mD124.4 lm/W2985.6 lm/mE
2700 K191.6 lm/W4597.7 lm/mC166.3 lm/W3992.1 lm/mD134.8 lm/W3234.1 lm/mE
3000 K201.2 lm/W4829.6 lm/mB175.5 lm/W4211.2 lm/mC142.7 lm/W3425.2 lm/mE
3500 K204.2 lm/W4900.5 lm/mB179.2 lm/W4301.4 lm/mC147.5 lm/W3541.2 lm/mD
4000 K208 lm/W4992.8 lm/mB180.3 lm/W4327.1 lm/mC148.8 lm/W3571.2 lm/mD
5000 K207.8 lm/W4986.4 lm/mB181.5 lm/W4355 lm/mC149.7 lm/W3592.8 lm/mD
6500 K199.2 lm/W4780.2 lm/mC173.4 lm/W4161.8 lm/mC143.9 lm/W3453.6 lm/mE

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K152.6 lm/W1464.6 lm/mD122.6 lm/W1176.6 lm/mE———
2300 K170.1 lm/W1632.8 lm/mC136.6 lm/W1311.6 lm/mD110.7 lm/W1062.7 lm/mE
2700 K183.3 lm/W1759.2 lm/mC148.3 lm/W1423.7 lm/mD120.2 lm/W1153.8 lm/mE
3000 K192.5 lm/W1847.6 lm/mB156.5 lm/W1502.6 lm/mD127.3 lm/W1222.2 lm/mE
3500 K195.3 lm/W1875.2 lm/mB159.6 lm/W1532.1 lm/mD131.4 lm/W1261.2 lm/mE
4000 K201.1 lm/W1930.3 lm/mB163 lm/W1564.4 lm/mC134.5 lm/W1291.6 lm/mE
5000 K200.8 lm/W1927.4 lm/mB163 lm/W1564.4 lm/mC134.4 lm/W1290.2 lm/mE
6500 K192.5 lm/W1847.6 lm/mB156.4 lm/W1501.7 lm/mD129.8 lm/W1246.1 lm/mE

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 12 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K150 lm/W1800.1 lm/mD120.5 lm/W1446.2 lm/mE———
2300 K167.2 lm/W2006.9 lm/mC134.3 lm/W1612.1 lm/mE108.8 lm/W1305.6 lm/mF
2700 K180.2 lm/W2162.3 lm/mC145.8 lm/W1749.9 lm/mD118.2 lm/W1418.1 lm/mE
3000 K189.2 lm/W2270.9 lm/mB153.9 lm/W1846.9 lm/mD125.2 lm/W1502.3 lm/mE
3500 K192.1 lm/W2304.8 lm/mB156.9 lm/W1883.1 lm/mD129.2 lm/W1550.2 lm/mE
4000 K197.7 lm/W2372.5 lm/mB160.2 lm/W1922.8 lm/mC132.3 lm/W1587.5 lm/mE
5000 K197.4 lm/W2369 lm/mB160.2 lm/W1922.8 lm/mC132.2 lm/W1586.4 lm/mE
6500 K189.2 lm/W2270.9 lm/mB153.8 lm/W1845.7 lm/mD127.7 lm/W1532.4 lm/mE

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 14.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K147.5 lm/W2124.1 lm/mD118.5 lm/W1706.4 lm/mE———
2300 K164.4 lm/W2368 lm/mC132.1 lm/W1902.1 lm/mE107 lm/W1540.8 lm/mF
2700 K177.2 lm/W2551.3 lm/mC143.4 lm/W2064.8 lm/mD116.2 lm/W1673.3 lm/mE
3000 K186.1 lm/W2679.5 lm/mB151.3 lm/W2179.2 lm/mD123.1 lm/W1772.6 lm/mE
3500 K188.9 lm/W2719.5 lm/mB154.3 lm/W2221.9 lm/mD127 lm/W1829.1 lm/mE
4000 K194.4 lm/W2799.4 lm/mB157.6 lm/W2268.8 lm/mD130.1 lm/W1873.2 lm/mE
5000 K194.1 lm/W2795.3 lm/mB157.6 lm/W2268.8 lm/mD130 lm/W1872 lm/mE
6500 K186.1 lm/W2679.5 lm/mB151.2 lm/W2177.8 lm/mD125.5 lm/W1807.2 lm/mE

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 19.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K142.6 lm/W2738.2 lm/mD114.6 lm/W2199.8 lm/mE———
2300 K159 lm/W3052.7 lm/mD127.7 lm/W2452.1 lm/mE103.4 lm/W1985.3 lm/mF
2700 K171.3 lm/W3289 lm/mC138.6 lm/W2661.8 lm/mD112.4 lm/W2157.1 lm/mE
3000 K179.9 lm/W3454.3 lm/mC146.3 lm/W2809.2 lm/mD119 lm/W2285.1 lm/mE
3500 K182.6 lm/W3505.8 lm/mC149.2 lm/W2864.3 lm/mD122.8 lm/W2357.9 lm/mE
4000 K188 lm/W3608.8 lm/mB152.3 lm/W2924.7 lm/mD125.8 lm/W2414.8 lm/mE
5000 K187.7 lm/W3603.5 lm/mB152.3 lm/W2924.7 lm/mD125.7 lm/W2413.4 lm/mE
6500 K179.9 lm/W3454.3 lm/mC146.2 lm/W2807.5 lm/mD121.4 lm/W2330.9 lm/mE

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 24 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K137.9 lm/W3309.2 lm/mD110.8 lm/W2658.5 lm/mE———
2300 K153.7 lm/W3689.3 lm/mD123.5 lm/W2963.5 lm/mE100 lm/W2400 lm/mF
2700 K165.6 lm/W3974.9 lm/mC134 lm/W3216.9 lm/mE108.6 lm/W2607 lm/mF
3000 K173.9 lm/W4174.7 lm/mC141.5 lm/W3395.1 lm/mD115.1 lm/W2761.6 lm/mE
3500 K176.5 lm/W4236.9 lm/mC144.2 lm/W3461.7 lm/mD118.7 lm/W2849.7 lm/mE
4000 K181.7 lm/W4361.5 lm/mC147.3 lm/W3534.7 lm/mD121.6 lm/W2918.4 lm/mE
5000 K181.5 lm/W4355 lm/mC147.3 lm/W3534.7 lm/mD121.5 lm/W2916 lm/mE
6500 K173.9 lm/W4174.7 lm/mC141.4 lm/W3393 lm/mD117.3 lm/W2815.2 lm/mE

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 8.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K154.1 lm/W1259.4 lm/mD123.8 lm/W1011.8 lm/mE———
2300 K171.8 lm/W1403.7 lm/mC138 lm/W1127.5 lm/mD111.8 lm/W913.6 lm/mE
2700 K185.1 lm/W1513 lm/mB149.8 lm/W1223.9 lm/mD121.4 lm/W991.9 lm/mE
3000 K194.4 lm/W1589 lm/mB158.1 lm/W1292 lm/mD128.6 lm/W1050.7 lm/mE
3500 K197.3 lm/W1612.6 lm/mB161.2 lm/W1317.4 lm/mC132.7 lm/W1084.3 lm/mE
4000 K203.1 lm/W1659.9 lm/mB164.6 lm/W1345.4 lm/mC135.9 lm/W1110.6 lm/mD
5000 K202.8 lm/W1657.4 lm/mB164.6 lm/W1345 lm/mC135.8 lm/W1109.8 lm/mD
6500 K194.4 lm/W1589 lm/mB158 lm/W1291.5 lm/mD131.1 lm/W1071.3 lm/mE

High-Power LED Strip: Heat Dissipation & Aluminum Channel Guide

At up to 24W/m, 10162 is a high-power SMD LED strip. Above roughly 14.4W/m the tape can no longer shed its own heat through the FPC alone — an aluminum channel is part of the luminaire, not an accessory.

Why high-wattage strips need a heat sink

  • Aluminum conducts heat roughly 30× faster than the plastics, MDF or gypsum a strip is usually stuck to, so a bare high-power run traps heat under the tape.
  • LED lifetime (LM-80 / TM-21) is driven by solder-point temperature Tc. Keeping Tc inside the datasheet limit — DENO strips are rated Tc ≤ 75°C — is what preserves the rated L70 lifetime and colour stability.
  • Never run 14.4W/m or more coiled on the reel, inside a sealed plastic diffuser, or directly on wood, wallpaper or foam.

Sizing rule: FPC width vs channel inner width

  • Channel inner width ≥ FPC width + 2mm. This strip is 10mm wide, so it needs at least 12mm of inner width.
  • The 2mm clearance absorbs extrusion tolerance and lets the tape be seated or replaced without scraping the side walls or the wiring.
  • A frosted or opal PC cover then diffuses the higher lumen output into an even, dot-free line instead of visible hot spots.

Aluminum channels that fit this strip

Recommended LED Channels

Mount this LED strip in a DENO LED aluminum profile for heat dissipation, physical protection and diffused, dot-free output.

This strip is 10mm wide, so it needs a channel with at least 12mm inner width (10mm + 2mm clearance). Every profile below meets that.

Modelos relacionados nesta série

See every model in SMD LED Strip Series or narrow to 2835. Compare wattage, lumen output and run length in the ProCalc parameter library, or request OEM/ODM pricing on the custom manufacturing page.

Perguntas Frequentes

Quais são as principais especificações do modelo 10162?

10162: 2835, 180 LEDs/m, DC 24V, PCB de 10mm, FPCB de cobre de 3oz, corte a cada 9LEDs/50mm. Dados fotométricos completos, diagramas de ligação e relatórios de ensaio estão disponíveis na seção de downloads desta página.

Para quais ambientes esta Fita de LED de alta eficácia luminosa é indicada?

O grau de proteção contra ingresso deste modelo está indicado na ficha técnica. Como Fita de LED de alta eficácia luminosa, ela é especificada para as condições de serviço indicadas na ficha técnica, e a DENO pode fornecer revestimentos alternativos, capas ou encapsulamento IP68 para instalações em condições mais severas.

A DENO pode personalizar esta Fita de LED de alta eficácia luminosa para um projeto?

Sim. A DENO fabrica a série de Fitas SMD de Alta Eficácia Luminosa como fornecedora OEM e ODM: comprimento do rolo, temperatura de cor, nível de IRC (CRI), largura do PCB, impermeabilização e identificação com marca própria podem ser especificados. Solicite um Orçamento para consultar o prazo de entrega e os preços do projeto.

Quanto uma Fita de LED de alta eficácia luminosa pode reduzir o consumo de energia?

A substituição de uma fita típica de 100 lm/W por uma Fita de LED de alto fluxo luminoso de 180 a 200 lm/W reduz aproximadamente pela metade a potência necessária para o mesmo fluxo luminoso. Em um trecho longo de instalação comercial, isso também reduz a potência necessária do Driver / Fonte de Alimentação e ajuda a instalação a alcançar uma classe energética ErP melhor.

Qual Driver / Fonte de Alimentação para LED e qual comprimento de trecho são adequados para #10162?

10mm | 24V | 180LEDs | 50mm/corte | #10162 | Fita de LED 2835 de Alta Eficácia Luminosa e Alto Fluxo Luminoso é um produto de tensão constante de DC 24V, portanto, utilize um Driver / Fonte de Alimentação para LED de tensão constante de DC 24V com certificação CE ou UL e potência nominal cerca de 20% acima da carga conectada. O comprimento máximo de um único trecho é de 5m. Alimentação por uma extremidade: 5m / por ambas as extremidades: 10m. A alimentação por ambas as extremidades ou pelo ponto central reduz pela metade a distância percorrida no cobre e diminui a queda de tensão para aproximadamente um quarto.